Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
2688530
Weight
0.222 kg
This product is Not Cancellable/Not Returnable

AXL F BK PB - Bus coupler

Axioline F, Bus coupler, PROFIBUS DP, D-SUB-9 female connector, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connector

  • PROFIBUS connection via 9-pos. D-SUB socket
  • Electrical isolation between PROFIBUS interface and logic
  • Rotary coding switches for setting the PROFIBUS address
  • DP/V1 for class 1 and class 2 masters
  • PROFIBUS data transmission speed of 9.6 kbps to 12 Mbps
  • Dynamic configuration is supported
  • I&M functions
  • Firmware can be updated
  • Typical cycle time of the Axioline F local bus is around 10 μs
  • Supports the operation of Axioline Smart Elements
  • Supports passive Smart Elements (firmware version 2.20 or later)
Technical Specifications

Dimensions

Width45 mm
Height126.1 mm
Depth74 mm
Note on dimensionsThe depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).

PROFIBUS DP

Number of interfaces1
Connection MethodD-SUB-9 female connector
Transmission Speed9.6 kbps ... 12 Mbps

Axioline F local bus

Number of interfaces1
Connection MethodBus base module
Transmission Speed100 Mbps

Service

Number of interfaces1
Connection MethodMicro USB type B

Fieldbus: Local bus gateway

Max. number of local bus devices63 (Consider the logic current consumed by the devices)

System limits

Number of supported devicesmax. 63 (per station)
Number of local bus devices that can be connectedmax. 63

Product properties

Product familyAxioline F
Typeblock modular
Mounting Positionany (observe temperature derating)
Scope of deliveryincluding bus base module and Axioline F connector

Insulation characteristics

Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Potentials: Communications power UL feed-in (the supply of the Axioline F local bus UBus is generated from UL)

Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 567 mA (with 2 A at UBus for the I/Os and UL = 24 V)
Power consumptionmax. 13.7 W (2.0 A on UBus, UL = 24 V)
Protective circuitSurge protection; electronic
Protective circuitReverse polarity protection; electronic

Potentials: Axioline F local bus supply (UBus)

Supply Voltage5 V DC (via bus base module)
Power Supply Unit2 A

Electrical isolation/isolation of the voltage ranges

Test voltage: PROFIBUS interface / 24 V communications voltage (UL) feed-in500 V AC, 50 Hz, 1 min.
Test voltage: PROFIBUS interface / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 24 V communications voltage (UL) feed-in / functional ground500 V AC, 50 Hz, 1 min.

Connection technology

Connection nameAxioline F connector
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.

Conductor connection

Connection MethodPush-in connection
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Axioline F connector

Connection MethodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section, rigid0.2 mm² ... 1.5 mm²
Conductor cross section, flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 60 °C (Mounting position: wall mounting on horizontal DIN rail)
Ambient Temperature (Operation)-25 °C ... 55 °C (Mounting position: any)
Degree of ProtectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting

Mounting TypeDIN rail mounting
Mounting Positionany (observe temperature derating)
Accessories

Why Proax for Phoenix Contact AXL F BK PB?

Proax is an authorized distributor of Phoenix Contact AXL F BK PB and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesAXLFBKPB
Pack Size1
Recommended

Available for order

Phoenix Contact Availability