Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
1019121
Weight
0.055 kg
Series VAL-MS

VAL-MS 1000DC-PV-ST/4 - Type 2 surge protection plug

Replacement plug for PV arrester combinations from the VAL-MS 1000DC-PV-... product range

  • Increased safety, thanks to compliance with standard EN 50539-11
  • Reliable contact, thanks to integrated rotating latch
  • Easy replacement, thanks to plug-in arresters
  • Optimum inverter protection, thanks to low protection level
  • Efficient replacement of defective plugs, thanks to visual status indicator
  • Protection against mismatching, thanks to keyed plugs and base elements
Technical Specifications

Product properties

Product familyVALVETRAB MS
IEC test classificationPV II
IEC test classificationPV T2
EN typeT2
IEC power supply systemDC
TypeMale
Installation locationInterior
Installation location of the disconnect deviceInternal
AccessibilityAccessible
SPD failure behaviorOCFM (Open-Circuit Failure Mode)
Surge protection fault messageoptical

Insulation characteristics

Overvoltage categoryIII
Pollution degree2

Connection data

Connection Methodpluggable

Dimensions

Width17.5 mm
Height52.4 mm
Depth55.3 mm
Horizontal pitch1 Div.

Material specifications

Colorblack (RAL 9005)
Colorlight grey (RAL 7035)
Flammability rating according to UL 94V-0
CTI value of material600
Insulating materialPA 6.6-FR
Material groupI
Housing MaterialPA 6.6-FR

Protective circuit

Standby power consumption PC≤ 25.00 mVA
Nominal discharge current In (8/20) µs15 kA
Maximum discharge current Imax (8/20) µs40 kA
Voltage protection level Up≤ 1.9 kV
Residual voltage Ures≤ 1.9 kV (at In)
Residual voltage Ures≤ 1.5 kV (at 5 kA)
Residual voltage Ures≤ 1.7 kV (at 10 kA)
Residual voltage Ures≤ 2 kV (at 20 kA)
Residual voltage Ures≤ 2.3 kV (at 30 kA)
Residual voltage Ures≤ 2.5 kV (at 40 kA)
Response time tA≤ 25 ns

Protective circuit DC voltage side (DC)

Open circuit voltage UOCSTC≤ 487.5 V DC
Maximum discharge current Imax (8/20) µs40 kA
Response time tA≤ 25 ns
Insulation resistance Riso> 5 GΩ (at 500 V DC)
Nominal discharge current In (8/20) µs15 kA
Continuous operating current ICPV< 20 µA
Maximum continuous operating voltage UCPV585 V DC
Short-circuit current rating ISCPV2000 A
Residual voltage Ures≤ 1.9 kV (at In)
Residual voltage Ures≤ 1.5 kV (at 5 kA)
Residual voltage Ures≤ 1.7 kV (at 10 kA)
Residual voltage Ures≤ 2 kV (at 20 kA)
Residual voltage Ures≤ 2.3 kV (at 30 kA)
Residual voltage Ures≤ 2.5 kV (at 40 kA)
Voltage protection level Up≤ 1.9 kV
Standby power consumption PC≤ 25.00 mVA

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m (amsl)
Permissible humidity (operation)5 % ... 95 %
Shock (operation)60g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (Operation)7.5g (5-500 Hz/2.5 h/XYZ)

UL specifications

Maximum continuous operating voltage MCOV1170 V DC
Short-circuit current rating (SCCR)50 kA
Voltage protection rating VPR3 kV
Nominal discharge current In10 kA
Mode of protection(L+) - (L-)
Mode of protection(L+) - G
Mode of protection(L-) - G
Nominal Voltage1170 V DC
Power distribution systemDC PV
SPD Type1CA

Standards and Regulations

Standards/specificationsEN 61643-31
Note2019
Standards/specificationsIEC 61643-31
Note2018

Mounting

Mounting Typeon base element
Accessories

Why Proax for Phoenix Contact VAL-MS 1000DC-PV-ST/4?

Proax is an authorized distributor of Phoenix Contact VAL-MS 1000DC-PV-ST/4 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesVALMS1000DCPVST4
Pack Size4
Recommended
Sold in quantities of 4

Available for order