Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
2700064
Weight
0.183 kg
This product is Not Cancellable/Not Returnable
Series IB-IL-SGI

IB IL SGI 1/CAL - Inline terminal

Inline analog strain gauge input terminal, without accessories, evaluating electronics with EC type approval

  • 1 input for DMS
  • Serial interface for external weight displays
  • Connection of strain gauges in 6-conductor technology
  • Electronic evaluating device to set up non-automatic weighing instruments (NAWI)
  • Can be calibrated by EC type approval according to standards EN 45501 and OIML R76
  • Alibi storage for up to 65536 test reports
  • Zero point, tare, and standstill display
  • Up to 3000 pitch values
  • Parameterization and calibration using FDT/DTM technology
  • Various filter settings
Technical Specifications

Dimensions

Width48.8 mm
Height120 mm
Depth71.5 mm
Note on dimensionsDimensions with covering hood

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area

Material specifications

Colorgreen

Inline local bus

Connection MethodInline data jumper
Transmission Speed500 kbps

Serial

DesignationRS-485
NetworkYes
AddressingAddress 0 = Broadcast, alternating display of measured gross/net value and measured tare value
AddressingAddress 1 = Measured gross/net value
AddressingAddress 2 = Measured tare value
AddressingAddress 3 ... 9 = reserved
Termination resistor120 Ω
Transmission protocolSTX/ETX

System properties

Memory TypeMeasurement protocol memory Alibi memory: non-volatile Flash memory 20 years

Module

ID code (dec.)220
ID code (hex)DC
Length code (hex)02
Length code (dec)02
Process data channel32 bit
Input address area4 Byte
Output address area4 Byte
Register length64 bit
Required parameter data 23 Byte
Required configuration data 5 Byte

Analog

Description of the inputInput channel for strain gauge
Number of Inputs1
Connection technology6-wire, twisted pair shielded cable
Bridge difference UdMeasuring range specified by selecting the characteristic
Bridge voltage U05 V
Measured value representationProcess data: status bits and measured value including decimal places of the gross/net display
Measured value representationPCP: see PCP; test report meets the requirements of DIN  EN 45501 and OIML  R76
Process data updatetyp. 100 ms
Characteristics±1 mV/V, ±2 mV/V, ±3 mV/V, ±3.33 mV/V, ±4 mV/V, ±5 mV/V

Contacts

DescriptionLock of parameters
Quantity1 (PSa - PSb)
LogicPSa - PSb connected = Parameter locked
Typical response time< 100 ms

Analog:

Protective circuitShort-circuit protection of the voltage outputs; Yes, at least 1 minute through temperature monitoring

Analog

Output descriptionVoltage output
Number of Outputs1
Impedance> 55 Ω
Impedancemax. 5 kΩ
Output Voltagetyp. 5 V ±2 %
Output Voltagemax. 5 V ±5 %
Output Currentmax. 90 mA
Maximum output currentmax. 90 mA

Product properties

Typemodular
TypeInline
Operating modeProcess data operation with 2 words, PCP with 2 words
Diagnostics messagesFailure of the power supply at UANA Error message in the process data
Diagnostics messagesFailure of or insufficient communications power UL I/O error message sent to the bus coupler
Diagnostics messagesI/O error Error message in the process data
Diagnostics messagesUser error Error message in the process data

Real-time clock

Description realtime clockSecond, minute, hour, day, month, year 5 years, timer buffered

Potentials

Power consumptiontyp. 1 W (Device in nominal operation)
Power consumptionmax. 2 W (Device with maximum load)

Potentials: Communications power (UL)

Supply Voltage7.5 V DC (via voltage jumper)
Current drawmax. 100 mA
Current drawtyp. 80 mA

Potentials: Supply of analog modules (UANA)

Supply Voltage24 V DC (via voltage jumper)
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 50 mA
Current drawtyp. 12 mA (For a typical load of 350 Ω and display)
Current draw43 mA (for a maximum load of 55 Ω and display)

Electrical isolation/isolation of the voltage ranges

Test voltage: Logic/analog I/O (digital isolator)500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (UANA)/analog I/O (DC/DC converter)500 V AC, 50 Hz, 1 min.
Test voltage: RS-485/analog I/O (isolating distance)500 V AC, 50 Hz, 1 min.
Test voltage: Contacts PSa - PSb/analog I/O (isolating distance)500 V AC, 50 Hz, 1 min.
Test voltage: Functional ground/analog I/O (isolating distance)500 V AC, 50 Hz, 1 min.
Test voltage: Logic/24 V supply (UANA) (DC/DC converter)500 V AC, 50 Hz, 1 min.
Test voltage: RS-485/24 V supply (UANA) (DC/DC converter)500 V AC, 50 Hz, 1 min.
Test voltage: Functional ground/24 V supply (UANA) (isolating distance)500 V AC, 50 Hz, 1 min.
Test voltage: Logic/RS-485 (digital isolator)500 V AC, 50 Hz, 1 min.
Test voltage: Functional ground/RS-485 (isolating distance)500 V AC, 50 Hz, 1 min.
Test voltage: Logic/contacts PSa - PSb (optocoupler)500 V AC, 50 Hz, 1 min.
Test voltage: Functional ground/contacts PSa - PSb (isolating distance)500 V AC, 50 Hz, 1 min.
Test voltage: Logic/functional ground (isolating distance)500 V AC, 50 Hz, 1 min.

Connection technology

Connection nameInline connector

Conductor connection

Connection MethodSpring-cage connection
Conductor cross section rigid0.08 mm² ... 1.5 mm²
Conductor cross section flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Inline connector

Connection MethodSpring-cage connection
Conductor cross section, rigid0.08 mm² ... 1.5 mm²
Conductor cross section, flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

SMKDS terminals

Connection MethodScrew connection
Conductor cross section, rigid0.14 mm² ... 1.5 mm²
Conductor cross section, flexible0.14 mm² ... 1 mm²
Conductor cross section AWG26 ... 16
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 55 °C (Type approval according to DIN EN 45501 and OIML R76: -10°C ... 40°C)
Degree of ProtectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)10 % ... 95 % (non-condensing)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting

Mounting TypeDIN rail mounting

Why Proax for Phoenix Contact IB IL SGI 1/CAL?

Proax is an authorized distributor of Phoenix Contact IB IL SGI 1/CAL and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesIBILSGI1CAL
Pack Size1
Recommended

Available for order