Series IB-IL-SGI
IB IL SGI 1/CAL - Inline terminal
Inline analog strain gauge input terminal, without accessories, evaluating electronics with EC type approval
- 1 input for DMS
- Serial interface for external weight displays
- Connection of strain gauges in 6-conductor technology
- Electronic evaluating device to set up non-automatic weighing instruments (NAWI)
- Can be calibrated by EC type approval according to standards EN 45501 and OIML R76
- Alibi storage for up to 65536 test reports
- Zero point, tare, and standstill display
- Up to 3000 pitch values
- Parameterization and calibration using FDT/DTM technology
- Various filter settings
Technical Specifications
Dimensions
Width | 48.8 mm |
Height | 120 mm |
Depth | 71.5 mm |
Note on dimensions | Dimensions with covering hood |
Utilization restriction
EMC note | EMC: class A product, see manufacturer's declaration in the download area |
Material specifications
Color | green |
Inline local bus
Connection Method | Inline data jumper |
Transmission Speed | 500 kbps |
Serial
Designation | RS-485 |
Network | Yes |
Addressing | Address 0 = Broadcast, alternating display of measured gross/net value and measured tare value |
Addressing | Address 1 = Measured gross/net value |
Addressing | Address 2 = Measured tare value |
Addressing | Address 3 ... 9 = reserved |
Termination resistor | 120 Ω |
Transmission protocol | STX/ETX |
System properties
Memory Type | Measurement protocol memory Alibi memory: non-volatile Flash memory 20 years |
Module
ID code (dec.) | 220 |
ID code (hex) | DC |
Length code (hex) | 02 |
Length code (dec) | 02 |
Process data channel | 32 bit |
Input address area | 4 Byte |
Output address area | 4 Byte |
Register length | 64 bit |
Required parameter data | 23 Byte |
Required configuration data | 5 Byte |
Analog
Description of the input | Input channel for strain gauge |
Number of Inputs | 1 |
Connection technology | 6-wire, twisted pair shielded cable |
Bridge difference Ud | Measuring range specified by selecting the characteristic |
Bridge voltage U0 | 5 V |
Measured value representation | Process data: status bits and measured value including decimal places of the gross/net display |
Measured value representation | PCP: see PCP; test report meets the requirements of DIN EN 45501 and OIML R76 |
Process data update | typ. 100 ms |
Characteristics | ±1 mV/V, ±2 mV/V, ±3 mV/V, ±3.33 mV/V, ±4 mV/V, ±5 mV/V |
Contacts
Description | Lock of parameters |
Quantity | 1 (PSa - PSb) |
Logic | PSa - PSb connected = Parameter locked |
Typical response time | < 100 ms |
Analog:
Protective circuit | Short-circuit protection of the voltage outputs; Yes, at least 1 minute through temperature monitoring |
Analog
Output description | Voltage output |
Number of Outputs | 1 |
Impedance | > 55 Ω |
Impedance | max. 5 kΩ |
Output Voltage | typ. 5 V ±2 % |
Output Voltage | max. 5 V ±5 % |
Output Current | max. 90 mA |
Maximum output current | max. 90 mA |
Product properties
Type | modular |
Type | Inline |
Operating mode | Process data operation with 2 words, PCP with 2 words |
Diagnostics messages | Failure of the power supply at UANA Error message in the process data |
Diagnostics messages | Failure of or insufficient communications power UL I/O error message sent to the bus coupler |
Diagnostics messages | I/O error Error message in the process data |
Diagnostics messages | User error Error message in the process data |
Real-time clock
Description realtime clock | Second, minute, hour, day, month, year 5 years, timer buffered |
Potentials
Power consumption | typ. 1 W (Device in nominal operation) |
Power consumption | max. 2 W (Device with maximum load) |
Potentials: Communications power (UL)
Supply Voltage | 7.5 V DC (via voltage jumper) |
Current draw | max. 100 mA |
Current draw | typ. 80 mA |
Potentials: Supply of analog modules (UANA)
Supply Voltage | 24 V DC (via voltage jumper) |
Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw | max. 50 mA |
Current draw | typ. 12 mA (For a typical load of 350 Ω and display) |
Current draw | 43 mA (for a maximum load of 55 Ω and display) |
Electrical isolation/isolation of the voltage ranges
Test voltage: Logic/analog I/O (digital isolator) | 500 V AC, 50 Hz, 1 min. |
Test voltage: 24 V supply (UANA)/analog I/O (DC/DC converter) | 500 V AC, 50 Hz, 1 min. |
Test voltage: RS-485/analog I/O (isolating distance) | 500 V AC, 50 Hz, 1 min. |
Test voltage: Contacts PSa - PSb/analog I/O (isolating distance) | 500 V AC, 50 Hz, 1 min. |
Test voltage: Functional ground/analog I/O (isolating distance) | 500 V AC, 50 Hz, 1 min. |
Test voltage: Logic/24 V supply (UANA) (DC/DC converter) | 500 V AC, 50 Hz, 1 min. |
Test voltage: RS-485/24 V supply (UANA) (DC/DC converter) | 500 V AC, 50 Hz, 1 min. |
Test voltage: Functional ground/24 V supply (UANA) (isolating distance) | 500 V AC, 50 Hz, 1 min. |
Test voltage: Logic/RS-485 (digital isolator) | 500 V AC, 50 Hz, 1 min. |
Test voltage: Functional ground/RS-485 (isolating distance) | 500 V AC, 50 Hz, 1 min. |
Test voltage: Logic/contacts PSa - PSb (optocoupler) | 500 V AC, 50 Hz, 1 min. |
Test voltage: Functional ground/contacts PSa - PSb (isolating distance) | 500 V AC, 50 Hz, 1 min. |
Test voltage: Logic/functional ground (isolating distance) | 500 V AC, 50 Hz, 1 min. |
Connection technology
Connection name | Inline connector |
Conductor connection
Connection Method | Spring-cage connection |
Conductor cross section rigid | 0.08 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.08 mm² ... 1.5 mm² |
Conductor cross section AWG | 28 ... 16 |
Stripping length | 8 mm |
Inline connector
Connection Method | Spring-cage connection |
Conductor cross section, rigid | 0.08 mm² ... 1.5 mm² |
Conductor cross section, flexible | 0.08 mm² ... 1.5 mm² |
Conductor cross section AWG | 28 ... 16 |
Stripping length | 8 mm |
SMKDS terminals
Connection Method | Screw connection |
Conductor cross section, rigid | 0.14 mm² ... 1.5 mm² |
Conductor cross section, flexible | 0.14 mm² ... 1 mm² |
Conductor cross section AWG | 26 ... 16 |
Stripping length | 8 mm |
Ambient conditions
Ambient Temperature (Operation) | -25 °C ... 55 °C (Type approval according to DIN EN 45501 and OIML R76: -10°C ... 40°C) |
Degree of Protection | IP20 |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Ambient temperature (storage/transport) | -25 °C ... 85 °C |
Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) |
Standards and Regulations
Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Mounting
Mounting Type | DIN rail mounting |
Why Proax for Phoenix Contact 2700064?
Proax is an authorized distributor of Phoenix Contact 2700064 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended