NBC-10,0-94B/FS SCO - Network cable
Network cable, Ethernet CAT5 (1 Gbps), 8-position, PUR halogen-free, water blue RAL 5021, shielded (Aluminum-coated foil, tinned copper braided shield), free cable end, on Socket straight M12 SPEEDCON, coding: A / IP67, cable length: 10 m
Technical Specifications
Notes
General | Further products with variable cable type and variable cable length can be found in the accessories section |
Product properties
Application | Standard |
Sensor Type | Ethernet |
Number of Positions | 8 |
No. of cable outlets | 1 |
Shielded | yes |
Coding | A |
Interfaces
Bus system | Ethernet |
Signal type/category | Ethernet CAT5 (based on IEC 11801), 1 Gbps |
Signaling
Status display | No |
Status display present | No |
Electrical properties
Nominal voltage UN | 48 V AC |
Nominal voltage UN | 60 V DC |
Nominal current IN | 2 A |
Transmission medium | Copper |
Transmission characteristics (category) | CAT5 (IEC 11801:2002) |
Material specifications
Seal material | NBR |
Connection 1
Type | free cable end |
Connection 2
Type | free cable end |
Cable/line
Cable Length | 10 m |
Ethernet flexible CAT5, 4-pair [94B]
Cable weight | 47 kg/km |
UL AWM style | 20963 (80°C/30 V) |
Number of Positions | 8 |
Shielded | yes |
Cable Type | Ethernet flexible CAT5, 4-pair [94B] |
Conductor structure | 4x2xAWG26/7, SF/UTP |
Signal runtime | 5.3 ns/m |
Conductor structure signal line | 7x 0.16 mm |
AWG Signal Line | 26 |
Conductor Cross Section | 4x 2x 0.14 mm² |
Wire diameter incl. insulation | 0.96 mm |
External Cable Diameter | 6.40 mm ±0.2 mm |
Outer sheath, material | PUR |
External sheath, color | water blue RAL 5021 |
Conductor material | Bare Cu litz wires |
Material wire insulation | Foamed PE |
Single wire, color | white/blue-blue, white/orange-orange, white/green-green, white/brown-brown |
Thickness, outer sheath | 1.05 mm |
Twisted pairs | 2 cores to the pair |
Overall twist | 4 pairs for core |
Optical shield covering | 70 % |
Insulation resistance | ≥ 5 GΩ*km |
Coupling resistance | ≤ 100.00 mΩ/m (at 10 MHz) |
Loop resistance | ≤ 290.00 Ω/km |
Wave impedance | 100 Ω ±5 Ω (at 100 MHz) |
Cable capacity | 48 nF/km (at 1 kHz) |
Nominal voltage, cable | ≤ 100 V |
Test voltage Core/Core | 700 V (50 Hz, 1 min.) |
Test voltage Core/Shield | 700.00 V (50 Hz, 1 min.) |
Minimum bending radius, fixed installation | 4 x D |
Minimum bending radius, flexible installation | 8 x D |
Smallest bending radius, fixed installation | 26 mm |
Smallest bending radius, movable installation | 52 mm |
Tensile strength | ≤ 100 N |
Near end crosstalk attenuation (NEXT) | 71.3 dB (with 1 MHz) |
Near end crosstalk attenuation (NEXT) | 62.3 dB (at 4 МHz) |
Near end crosstalk attenuation (NEXT) | 56.3 dB (at 10 MHz) |
Near end crosstalk attenuation (NEXT) | 53.2 dB (at 16 MHz) |
Near end crosstalk attenuation (NEXT) | 51.8 dB (at 20 МHz) |
Near end crosstalk attenuation (NEXT) | 48.9 dB (at 31.25 МHz) |
Near end crosstalk attenuation (NEXT) | 44.4 dB (at 62.5 МHz) |
Near end crosstalk attenuation (NEXT) | 41.3 dB (at 100 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 62.3 dB (with 1 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 53.3 dB (at 4 МHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 47.3 dB (at 10 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 44.2 dB (at 16 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 42.8 dB (at 20 МHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 39.9 dB (at 31.25 МHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 35.4 dB (at 62.5 МHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 32.3 dB (at 100 MHz) |
Return attenuation (RL) | 23 dB (at 4 МHz) |
Return attenuation (RL) | 24.1 dB (at 8 МHz) |
Return attenuation (RL) | 25 dB (at 10 MHz) |
Return attenuation (RL) | 25 dB (at 16 MHz) |
Return attenuation (RL) | 25 dB (at 20 МHz) |
Return attenuation (RL) | 23.6 dB (at 31.25 МHz) |
Return attenuation (RL) | 21.5 dB (at 62.5 МHz) |
Return attenuation (RL) | 20.1 dB (at 100 MHz) |
Shield attenuation | 3.2 dB (with 1 MHz) |
Shield attenuation | 6 dB (at 4 МHz) |
Shield attenuation | 9.5 dB (at 10 MHz) |
Shield attenuation | 12.1 dB (at 16 MHz) |
Shield attenuation | 13.6 dB (at 20 МHz) |
Shield attenuation | 17.1 dB (at 31.25 МHz) |
Shield attenuation | 24.8 dB (at 62.5 МHz) |
Shield attenuation | 32 dB (at 100 MHz) |
Halogen-free | according to IEC 60754-1 |
Flame resistance | according to IEC 60332-1-2 |
Resistance to Oil | in accordance with EN 60811-2-1 |
Ambient Temperature (Operation) | -40 °C ... 80 °C (cable, fixed installation) |
Ambient Temperature (Operation) | -20 °C ... 80 °C (Cable, flexible installation) |
Ambient temperature (installation) | -20 °C ... 80 °C |
Ambient conditions
Degree of Protection | IP65 |
Degree of Protection | IP67 |
Degree of Protection | IP65/IP67 |
Ambient Temperature (Operation) | -25 °C ... 85 °C (M12 connector) |
M12
Standard designation | M12 connector |
Standards/specifications | IEC 61076-2-101 |
Accessories
Why Proax for Phoenix Contact 1407442?
Proax is an authorized distributor of Phoenix Contact 1407442 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended