Official Distributor
SKU
Series NBC
NBC-1,0-94F/M12FSX - Network cable
Network cable, Ethernet CAT6A (10 Gbps) CAT6A (10 Gbps), 8-position, PUR halogen-free, water blue RAL 5021, shielded (Tinned copper braided shield), Advanced Shielding Technology, free cable end, on Socket straight M12, coding: X / IP67, cable length: 1 m
Technical Specifications
Product properties
Application | Standard |
Sensor Type | Ethernet |
Number of Positions | 8 |
No. of cable outlets | 1 |
Shielded | yes |
Coding | X |
Interfaces
Bus system | Ethernet |
Signal type/category | Ethernet CAT6A, 10 Gbps |
Signaling
Status display | No |
Status display present | No |
Electrical properties
Nominal voltage UN | 48 V AC |
Nominal voltage UN | 60 V DC |
Nominal current IN | 0.5 A |
Transmission medium | Copper |
Transmission characteristics (category) | CAT6A |
Connection 1
Type | M12, straight, 8-position, AST, Keying: X |
Number of Positions | 8 |
Shielded | yes |
Signal type/category | Ethernet CAT6A, 10 Gbps |
Insertion/withdrawal cycles | ≥ 100 |
Insulation resistance | ≥ 100 Ω |
Overvoltage category | II |
Degree of pollution | 3 |
Tightening torque | 0.4 Nm (M12 connector) |
Contact Material | CuZn |
Contact surface material | Ni/Au |
Contact carrier material | PA 6.6 |
Material for screw connection | Zinc die-cast, nickel-plated |
Seal material | FKM |
Flammability rating according to UL 94 | V0 |
Degree of Protection | IP65 |
Degree of Protection | IP67 |
Ambient Temperature (Operation) | -25 °C ... 85 °C |
Standard designation | M12 connector |
Standards/regulations | IEC 61076-2-109 |
Connection 2
Type | free cable end |
Cable/line
Cable Length | 1 m |
Ethernet 10 Gbit [94F]
Cable weight | 42 kg/km |
UL AWM style | 20963 (80°C/30 V) |
Number of Positions | 8 |
Shielded | yes |
Cable Type | Ethernet 10 Gbit [94F] |
Conductor structure | 4x2xAWG26/7; S/FTP |
Signal runtime | 5.13 ns/m |
Conductor structure signal line | 7x 0.16 mm |
AWG Signal Line | 26 |
Conductor Cross Section | 4x 2x 0.14 mm² |
Wire diameter incl. insulation | 1.04 mm |
External Cable Diameter | 6.40 mm ±0.2 mm |
Outer sheath, material | PUR |
External sheath, color | water blue RAL 5021 |
Conductor material | Bare Cu litz wires |
Material wire insulation | Foamed PE |
Single wire, color | white/blue-blue, white/orange-orange, white/green-green, white/brown-brown |
Thickness, outer sheath | 0.65 mm |
Twisted pairs | 2 cores to the pair |
Type of pair shielding | Aluminum-lined foil |
Overall twist | 4 pairs for core |
Optical shield covering | 70 % |
Insulation resistance | ≥ 500 MΩ*km |
Loop resistance | ≤ 290.00 Ω/km |
Wave impedance | 100 Ω ±5 Ω (at 100 MHz) |
Cable capacity | 47 nF/km |
Nominal voltage, cable | ≤ 100 V |
Test voltage Core/Core | 700 V (50 Hz, 1 min.) |
Test voltage Core/Shield | 700.00 V (50 Hz, 1 min.) |
Minimum bending radius, fixed installation | 4 x D |
Minimum bending radius, flexible installation | 8 x D |
Smallest bending radius, fixed installation | 26 mm |
Smallest bending radius, movable installation | 52 mm |
Tensile strength | ≤ 100 N |
Near end crosstalk attenuation (NEXT) | 75.3 dB (with 1 MHz) |
Near end crosstalk attenuation (NEXT) | 66.3 dB (at 4 МHz) |
Near end crosstalk attenuation (NEXT) | 61.8 dB (at 8 МHz) |
Near end crosstalk attenuation (NEXT) | 60.3 dB (at 10 MHz) |
Near end crosstalk attenuation (NEXT) | 57.2 dB (at 16 MHz) |
Near end crosstalk attenuation (NEXT) | 55.8 dB (at 20 МHz) |
Near end crosstalk attenuation (NEXT) | 54.3 dB (at 25 MHz) |
Near end crosstalk attenuation (NEXT) | 52.8 dB (at 31.25 МHz) |
Near end crosstalk attenuation (NEXT) | 48.4 dB (at 62.5 МHz) |
Near end crosstalk attenuation (NEXT) | 45.3 dB (at 100 MHz) |
Near end crosstalk attenuation (NEXT) | 40.8 dB (at 200 MHz) |
Near end crosstalk attenuation (NEXT) | 39.3 dB (at 250 MHz) |
Near end crosstalk attenuation (NEXT) | 38.1 dB (at 300 MHz) |
Near end crosstalk attenuation (NEXT) | 38.1 dB (at 400 MHz) |
Near end crosstalk attenuation (NEXT) | 38.1 dB (at 500 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 72.3 dB (with 1 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 63.3 dB (at 4 МHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 58.8 dB (at 8 МHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 57.3 dB (at 10 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 54.2 dB (at 16 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 52.8 dB (at 20 МHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 51.3 dB (at 25 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 49.9 dB (at 31.25 МHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 45.4 dB (at 62.5 МHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 42.3 dB (at 100 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 37.8 dB (at 200 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 36.3 dB (at 250 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 35.1 dB (at 300 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 33.3 dB (at 400 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 31.8 dB (at 500 MHz) |
Return attenuation (RL) | 20 dB (with 1 MHz) |
Return attenuation (RL) | 23 dB (at 4 МHz) |
Return attenuation (RL) | 24.5 dB (at 8 МHz) |
Return attenuation (RL) | 25 dB (at 10 MHz) |
Return attenuation (RL) | 25 dB (at 16 MHz) |
Return attenuation (RL) | 25 dB (at 20 МHz) |
Return attenuation (RL) | 24.2 dB (at 25 MHz) |
Return attenuation (RL) | 23.3 dB (at 31.25 МHz) |
Return attenuation (RL) | 20.7 dB (at 62.5 МHz) |
Return attenuation (RL) | 19 dB (at 100 MHz) |
Return attenuation (RL) | 16.4 dB (at 200 MHz) |
Return attenuation (RL) | 15.6 dB (at 250 MHz) |
Return attenuation (RL) | 15.6 dB (at 300 MHz) |
Return attenuation (RL) | 15.6 dB (at 400 MHz) |
Return attenuation (RL) | 15.6 dB (at 500 MHz) |
Shield attenuation | 3.1 dB (with 1 MHz) |
Shield attenuation | 5.7 dB (at 4 МHz) |
Shield attenuation | 8 dB (at 8 МHz) |
Shield attenuation | 8.9 dB (at 10 MHz) |
Shield attenuation | 11.2 dB (at 16 MHz) |
Shield attenuation | 12.6 dB (at 20 МHz) |
Shield attenuation | 14.1 dB (at 25 MHz) |
Shield attenuation | 15.8 dB (at 31.25 МHz) |
Shield attenuation | 22.5 dB (at 62.5 МHz) |
Shield attenuation | 28.7 dB (at 100 MHz) |
Shield attenuation | 41.4 dB (at 200 MHz) |
Shield attenuation | 46.6 dB (at 250 MHz) |
Shield attenuation | 51.4 dB (at 300 MHz) |
Shield attenuation | 60.1 dB (at 400 MHz) |
Shield attenuation | 67.9 dB (at 500 MHz) |
Shield attenuation | ≥ 80.00 dB (at 30 ... 100 MHz) |
Halogen-free | according to IEC 60754-1 |
Flame resistance | according to IEC 60332-1-2 |
Resistance to Oil | in accordance with DIN EN 60811-2-1 |
Ambient Temperature (Operation) | -40 °C ... 80 °C (cable, fixed installation) |
Ambient Temperature (Operation) | -20 °C ... 80 °C (Cable, flexible installation) |
Ambient temperature (installation) | -20 °C ... 80 °C |
Ambient conditions
Degree of Protection | IP65 |
Degree of Protection | IP67 |
M12
Standard designation | M12 connector |
Standards/specifications | IEC 61076-2-109 |
Why Proax for Phoenix Contact 1080728?
Proax is an authorized distributor of Phoenix Contact 1080728 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended