Proax

Currency
0 Items
proax logo
Cart
ABBOfficial Distributor

By ABB

SKU
MPN
1SAM350200R1011
Weight
1 kg
MS132-B is a compact and powerful range for motor protection up to 15 kW (400 V) / 32 A in width of 45 mm, complying with the latest railway rolling stock standards and allowing installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds. They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10. This type has also a clear and reliable indication of fault in a separate window in the event of short-circuit tripping. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory. These are suitable throughout the MS132-B/MS165-B range. – designed in accordance to the applicable parts of IEC 60077 standard – shocks and vibration withstand conforming to IEC 61373 (category 1, class B) – usable according to European fire and smoke safety standard EN 45545-2
Technical Specifications

Dimensions

Product Net Width45 mm
Product Net Height97.8 mm
Product Net Depth / Length86.55 mm
Product Net Weight0.31 kg

Technical

Rated Service Short-Circuit Breaking Capacity (Ics)(230 V AC) 100 kA
Rated Service Short-Circuit Breaking Capacity (Ics)(250 V DC) 3 Poles in Series 10 kA
Rated Service Short-Circuit Breaking Capacity (Ics)(400 V AC) 100 kA
Rated Service Short-Circuit Breaking Capacity (Ics)(440 V AC) 30 kA
Rated Service Short-Circuit Breaking Capacity (Ics)(500 V AC) 20 kA
Rated Service Short-Circuit Breaking Capacity (Ics)(690 V AC) 3 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(230 V AC) 100 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(400 V AC) 100 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(440 V AC) 30 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(500 V AC) 20 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(690 V AC) 3 kA
Rated Instantaneous Short-Circuit Current Setting (Ii)240 A
Setting range10 ... 16 A
Rated Operational Power AC-3 (Pe)(400 V) Three Phase 7.5 kW
Rated Operational Power AC-3e (Pe)(400 V) Three Phase 7.5 kW
Rated Operational VoltageMain Circuit 690 V AC
Rated Operational VoltageMain Circuit 250 V DC
Rated Operational Current (Ie)16 A
Rated Operational Current AC-3 (Ie)16 A
Rated Operational Current AC-3e (Ie)16 A
Rated Operational Current DC-5 (Ie)16 A
Rated Frequency (f)Main Circuit 50 Hz
Rated Frequency (f)Main Circuit 60 Hz
Operating Frequency (fsw)0 ... 400 Hz
Rated Impulse Withstand Voltage (Uimp)Main Circuit 6 kV
Rated Insulation Voltage (Ui)690 V
Power Lossat Rated Operating Conditions per Pole 1.1 ... 2.8 W
Number of Poles3
Conventional Free-air Thermal Current (Ith)Main Circuit 16 A
Degree of ProtectionHousing IP20
Degree of ProtectionMain Circuit Terminals IP10
Pollution degree3
Electrical Durability50000 cycle
Mechanical Durability100000 cycle
Terminal TypeScrew Terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 6 mm²
Connecting Capacity Main CircuitFlexible with Insulated Ferrule 1/2x 0.75 ... 6 mm²
Connecting Capacity Main CircuitFlexible 1/2x 1 ... 2.5 mm²
Connecting Capacity Main CircuitFlexible 1/2x 2.5 ... 6 mm²
Connecting Capacity Main CircuitRigid 1/2x 1 ... 2.5 mm²
Connecting Capacity Main CircuitRigid 1/2x 2.5 ... 6 mm²
Tightening torqueMain Circuit 2 N·m
Wire Stripping LengthMain Circuit 10 mm
Recommended Screw DriverPozidriv 2
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting on DIN RailTH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting DistanceElectrical Conductive Board, Horizontal - Up to 400 V 0 mm
Minimum Mounting DistanceElectrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Minimum Mounting DistanceElectrical Conductive Board, Vertical 75 mm
Minimum Mounting DistanceOther Device Same Type, Horizontal 0 mm
Minimum Mounting DistanceOther Device Same Type, Vertical 150 mm
Actuator TypeRotary Handle
Contact Position IndicationON / OFF / TRIP
StandardsIEC 60077-1 (applicable parts)
StandardsIEC 60077-2 (applicable parts)
StandardsIEC/EN 60947-1
StandardsIEC/EN 60947-2
StandardsIEC/EN 60947-4-1
RemarksUL508 Self-Protected Combination Motor Controller (Type E) in combination with feeder block S1-M3-xx

Technical UL/CSA

Short-circuit current rating (SCCR)Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 30 kA
Short-circuit current rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 35 kA
Short-circuit current rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kA
Short-circuit current rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kA
Short-circuit current rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA
Short-circuit current rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kA
Short-circuit current rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Horsepower Rating UL/CSA(200 V AC) Three Phase 3 Hp
Horsepower Rating UL/CSA(208 V AC) Three Phase 3 Hp
Horsepower Rating UL/CSA(220 ... 240 V AC) Three Phase 5 Hp
Horsepower Rating UL/CSA(440 ... 480 V AC) Three Phase 10 Hp
Horsepower Rating UL/CSA(550 ... 600 V AC) Three Phase 10 Hp
Full Load Amps Motor Use(200 V AC) Three Phase 11 A
Full Load Amps Motor Use(208 V AC) Three Phase 10.6 A
Full Load Amps Motor Use(220 ... 240 V AC) Three Phase 15.2 A
Full Load Amps Motor Use(440 ... 480 V AC) Three Phase 14 A
Full Load Amps Motor Use(550 ... 600 V AC) Three Phase 11 A
Locked Rotor Amps(200 V AC) Three Phase 73.6 A
Locked Rotor Amps(208 V AC) Three Phase 71 A
Locked Rotor Amps(220 ... 240 V AC) Three Phase 92 A
Locked Rotor Amps(440 ... 480 V AC) Three Phase 81 A
Locked Rotor Amps(550 ... 600 V AC) Three Phase 64.8 A
General Use Rating UL/CSA(600 V AC) 16 A
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 16-8 AWG
Connecting Capacity Main Circuit UL/CSAStranded 1/2x 16-8 AWG
Tightening Torque UL/CSAMain Circuit 18 in·lb

Why Proax for ABB MS132-16B?

Proax is an authorized distributor of ABB MS132-16B and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesMS13216B
Pack Size1
Recommended

Available for order

ABB Availability