The circuit breaker for transformer protection MS132-12T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 12 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks and terminal spacers are available as accessory.
Technical Specifications

Dimensions

Product Net Width45 mm
Product Net Height97.8 mm
Product Net Depth / Length86.05 mm
Product Net Weight0.31 kg

Technical

Rated Service Short-Circuit Breaking Capacity (Ics)(230 V AC) 100 kA
Rated Service Short-Circuit Breaking Capacity (Ics)(400 V AC) 100 kA
Rated Service Short-Circuit Breaking Capacity (Ics)(440 V AC) 30 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(400 V AC) 100 kA
Rated Instantaneous Short-Circuit Current Setting (Ii)240 A
Setting range8.0 ... 12 A
Rated Operational VoltageMain Circuit 690 V AC
Rated Operational Current (Ie)12 A
Rated Frequency (f)Main Circuit 50 Hz
Rated Frequency (f)Main Circuit 60 Hz
Operating Frequency (fsw)0 ... 400 Hz
Rated Impulse Withstand Voltage (Uimp)Main Circuit 6 kV
Rated Insulation Voltage (Ui)690 V
Power Lossat Rated Operating Conditions per Pole 0.9 ... 2.0 W
Number of Poles3
Conventional Free-air Thermal Current (Ith)Main Circuit 12 A
Degree of ProtectionHousing IP20
Degree of ProtectionMain Circuit Terminals IP10
Pollution degree3
Electrical Durability50000 cycle
Mechanical Durability100000 cycle
Terminal TypeScrew Terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 6 mm²
Connecting Capacity Main CircuitFlexible with Insulated Ferrule 1/2x 0.75 ... 6 mm²
Connecting Capacity Main CircuitFlexible 1/2x 1 ... 2.5 mm²
Connecting Capacity Main CircuitFlexible 1/2x 2.5 ... 6 mm²
Connecting Capacity Main CircuitRigid 1/2x 1 ... 2.5 mm²
Connecting Capacity Main CircuitRigid 1/2x 2.5 ... 6 mm²
Tightening torqueMain Circuit 2 N·m
Wire Stripping LengthMain Circuit 10 mm
Recommended Screw DriverM4
Recommended Screw DriverPozidriv 2
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting on DIN RailTH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting DistanceElectrical Conductive Board, Vertical 75 mm
Minimum Mounting DistanceOther Device Same Type, Horizontal 9 mm
Minimum Mounting DistanceOther Device Same Type, Vertical 150 mm
Actuator TypeRotary Handle
Contact Position IndicationON / OFF / TRIP
StandardsIEC/EN 60947-1
StandardsIEC/EN 60947-2
StandardsIEC/EN 60947-4-1

Technical UL/CSA

Short-circuit current rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kA
Short-circuit current rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Horsepower Rating UL/CSA(120 V AC) Single Phase 0.5 Hp
Horsepower Rating UL/CSA(220 ... 240 V AC) Single Phase 2 Hp
Full Load Amps Motor Use(120 V AC) Single Phase 9.8 A
Full Load Amps Motor Use(220 ... 240 V AC) Single Phase 12 A
Locked Rotor Amps(120 V AC) Single Phase 58.8 A
Locked Rotor Amps(220 ... 240 V AC) Single Phase 58.8 A
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 16-8 AWG
Connecting Capacity Main Circuit UL/CSAStranded 1/2x 16-8 AWG
Tightening Torque UL/CSAMain Circuit 16 in·lb

Why Proax for ABB MS132-12T?

Proax is an authorized distributor of ABB MS132-12T and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesMS13212T
Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

ABB Availability