2902958
Power terminal block - MINI MCR-SL-PTB-FM
Not in stock
2902961
MINI MCR-SL-FM-RC-NC - The fault monitoring module is used to evaluate and report group errors from the fault monitoring system and to monitor the supply voltages. The error is reported via an N/O contact. Screw connection, standard configuration.
Not in stock
2902990
PACT RCP-4000A-1A - This is an individual product; please order the complete set. The measuring transducer processes the mV signal of the upstream Rogowski coil. The measuring transducer has 8 current measuring ranges (100 A ... 4000 A AC) which can be set; max. output current of 1 A AC.
Not in stock
2903387
TC-C-PTB1-SC-05061516 - Cable set for MINI MCR-SL-PTB power module (Item No. 2864134) and MINI MCR-SL-TB feed-through module (Item No. 2811420), for use on the termination carrier for modules from the MINI Analog series.
Not in stock
2903522
EMD-BL-C-10-PT - Monitoring relay for monitoring single-phase currents of 0 ... 5 A AC or 0 ... 10 A AC, overcurrent/undercurrent or window, 1 changeover contact, with Push-in connection
Not in stock
2903524
Monitoring relay - EMD-BL-V-230-PT
Not in stock
2903525
Monitoring relay - EMD-BL-3V-400
Not in stock
2903527
EMD-BL-PH-480 - Monitoring relay for monitoring the phase sequence and asymmetry of 3-phase voltages at 208 ... 480 V AC / 120 ... 277 V AC, configurable asymmetry, 1 changeover contact, with screw connection
Not in stock
2903591
PV string monitoring module - SCK-M-U-1500V
Not in stock
2904504
MINI MCR-2-FM-RC - Fault monitoring module with plug-in connection technology for evaluating and reporting group errors from the FM system and for monitoring the supply voltages. Error message via N/C contact. Screw connection technology, standard configuration
Not in stock
2904508
MINI MCR-2-FM-RC-PT - Fault monitoring module with plug-in connection technology for evaluating and reporting group errors from the FM system and for monitoring the supply voltages. Error message via N/C contact. Push-in connection technology, standard configuration
Not in stock
2904921
PACT RCP-4000A-1A-D95 - Set consisting of a 1 A measuring transducer and a Rogowski coil with signal line. Length of Rogowski coil: 300 mm, diameter: 95 mm. Length of signal line: 3 m. The Rogowski coil measures the AC current of busbars and power lines.
Not in stock
2904922
PACT RCP-4000A-1A-D140 - Set consisting of one 1 A measuring transducer and one Rogowski coil with signal line. Length of Rogowski coil: 450 mm, diameter: 140 mm. Length of signal line: 3 m. The Rogowski coil measures the AC current of busbars and power lines.
Not in stock
2904923
PACT RCP-4000A-1A-D190 - Set consisting of a 1 A measuring transducer and a Rogowski coil with signal line. Length of Rogowski coil: 600 mm, diameter: 190 mm. Length of signal line: 3 m. The Rogowski coil measures the AC current of busbars and power lines.
Not in stock
2905680
MACX MCR-I20 - Connection terminal block for current signals, +20 mA ... -20 mA, for safe switching of limit values, in combination with MACX ...-T-UI... temperature transducers.
Not in stock
E52-CA15AY D=1.6 2M
Temp. sensor,Smooth tube, Thermocouple K, 0-650 deg.,dia. 1.6, 150mm, ASTM316L, pre-wired, 2m
26 Manufacturer stock
USA
26
E5CC-QX2AUM-000
Temp. controller, PRO, 1/16 DIN (48 x 48 mm), Plugin-type, 2 AUX, 1 x 12 VDC pulse OUT, 100 to 240 VAC
15 Manufacturer stock
USA
15
2924016
Power/input isolating amplifier - MACX MCR-EX-SL-RPSSI-I-SP
Not in stock
2924029
Power/input isolating amplifier - MACX MCR-EX-SL-RPSSI-I-UP-SP
Not in stock
2924061
MACX MCR-EX-SL-NAM-2RO-SP - Ex i NAMUR isolating amplifier For operating proximity sensors and switches in Ex areas. The signals are transmitted via 2 relay outputs (N/O contact) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
Not in stock