TC MOBILE I/O X300 - Signaling system

Compact signaling system for cellular networks to monitor analog and digital values as well as to switch relay outputs remotely. Communication is via the ODP protocol to an ODP server using GPRS. Supply voltage range of 10 V ... 60 V DC.

  • GPRS messaging system for remote control of outputs
  • Alarm generation on voltage failure via SMS
  • GSM mobile phone network: 850, 900, 1800, and 1900 MHz
  • Communication via ODP protocol
  • Data transmission either online or as historical values with time stamp
  • Two analog inputs
  • Configuration via USB and web browser
  • Compact design also for domestic installations (4 HP, DIN 43880)
  • Mounting on DIN rail or on the wall
Technical Specifications

Utilization restriction

CCCex noteUse in potentially explosive areas is not permitted in China.

Product properties

MTTF591 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
MTTF302 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
MTTF125 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)

Electrical properties

Maximum power dissipation for nominal condition3.85 W
Mains typeCellular communication

Supply

Supply Voltage Range10 V DC ... 60 V DC
Typical current consumption140 mA (24 V DC)
Max. current consumption180 mA

Digital

Description of the inputDigital input
Number of Inputs4
Switching threshold "0" signal in reference to UN≤ 0.3
Switching threshold "1" signal in reference to UN≥ 0.7

Analog

Description of the inputAnalog input
Number of Inputs2
Input SignalCurrent or voltage
Resolution15 bit
Input Impedance600 kΩ (Voltage inputs)
Input Impedance50 Ω (Current inputs)
Voltage input signal0 V DC ... 60 V DC
Current Input Signal0 mA ... 20 mA
Current Input Signal4 mA ... 20 mA (configurable)
Precision± 0.1 %

Switching

Output nameRelay output
Number of Outputs4
Contact switching typeN/O contact
Minimum Switching Voltage5 V
Maximum Switching Voltage60 V DC
Maximum Switching Voltage30 V AC
Limiting Continuous Current6 A
Switching capacity100 W (Power Source PS2, Pout ≤100 W)
Electrical service life5000 cycles

Supply

Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 2.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 2.5 mm²
Conductor cross section, flexible0.20 mm² ... 2.50 mm²
Conductor cross section, rigid0.20 mm² ... 2.50 mm²
Conductor cross section AWG24 ... 14
Stripping length6.50 mm
Tightening torque0.5 Nm ... 0.6 Nm (5-7 lbs-in, screw terminal blocks)

Interfaces

Web serveryes

Data: USB 2.0

Connection MethodMini-USB type B, 5-pos.
Transmission length≤ 3 m (only for configuration and diagnostics)

Wireless

Interface descriptionGSM / GPRS
Frequency Range850 MHz (2 W (EGSM))
Frequency Range900 MHz (2 W (EGSM))
Frequency Range1800 MHz (1 W (EGSM))
Frequency Range1900 MHz (1 W (EGSM))
GPRSMultislot Class 10

Dimensions

Width72 mm
Height90 mm
Depth62 mm

Material specifications

Color (Upper housing part)light grey (RAL 7035)
Color (Lower housing part)black (RAL 9005)
Material (Housing)Polycarbonate

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-25 °C ... 70 °C (SMS mode only, note the derating information in the technical documentation for data connection)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude2000 m
Permissible humidity (operation)0 % ... 95 %

CE

CertificateCE-compliant

ATEX

Identification II 3 G Ex nA nC IIC T4 Gc X
NotePlease follow the special installation instructions in the documentation!

Wireless approval USA, FCC

NotePart 15.107(a), 15.109(a)

Corrosive gas test

IdentificationISA-S71.04-1985 G3 Harsh Group A

Wireless approval, Europe

NoteRED 2014/53/EU

EMC data

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Conducted noise emissionClass B, area of application: Industry and residential

Electrostatic discharge

Standards/regulationsEN 61000-4-2
Contact discharge± 6 kV
Discharge in air± 8 kV
Indirect discharge± 6 kV
CommentsCriterion B

Electromagnetic HF field

Standards/regulationsEN 61000-4-3
Frequency Range26 MHz ... 6 GHz
Field intensity10 V/m
CommentsCriterion A

Fast transients (burst)

Standards/regulationsEN 61000-4-4
Input± 2 kV (Unshielded supply line)
Signal± 2 kV (Shielded signal line)
Signal± 2 kV (Analog I/O cables, unshielded)
CommentsCriterion B

Surge current load (surge)

Standards/regulationsEN 61000-4-5
Input± 0.5 kV (Symmetrical, unshielded supply line)
Input± 0.5 kV (Asymmetrical, unshielded supply line)
Signal± 1 kV (Data line, asymmetrical)
CommentsCriterion B

Conducted interference

Standards/regulationsEN 61000-4-6
Frequency Range0.15 MHz ... 80 MHz
CommentsCriterion A
Voltage10 V

Emitted interference

Emitted radio interference in acc. with EN 55011Class B, area of application: Industry and residential

Criteria

Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.

Standards and Regulations

Standards/regulationsEN 50360
Standards/regulationsEN 50121-4
Accessories

Why Proax for Phoenix Contact 2903807?

Proax is an authorized distributor of Phoenix Contact 2903807 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability