TC MOBILE I/O X200-4G - SMS relay
SMS relay and signaling module, European version, monitor analog and digital values via cellular network, switch relay outputs remotely, communication via SMS or cellular network data connection (e-mail transmission, app), supply voltage 10 V ... 60 V DC
- Future-proof 4G technology (LTE CAT1), simultaneous use of well-established 2G networks (GSM, GPRS, EDGE)
- Alerts via SMS in the field and, for example, via e-mail in the control room
- Message chain for sending an alert to the relevant service technician
- Alarm generation on voltage failure via SMS
- Free switching via phone call
- Cost control for prepaid cards
- Remote commands to avoid on-site servicing: switching, configuration commands, and logbook transmission
- Compact design also for domestic installations (4 HP, DIN 43880)
- Mounting on DIN rail or on the wall
Technical Specifications
Product properties
Application | I/O |
MTTF | 674 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
MTTF | 324 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) |
MTTF | 130 Years (SN 29500 standard, temperature 40°C, operating cycle 100%) |
Electrical properties
Mains type | Cellular communication |
Supply
Supply Voltage Range | 10 V DC ... 60 V DC |
Typical current consumption | 50 mA (24 V DC) |
Max. current consumption | 80 mA |
Digital
Description of the input | Digital input |
Number of Inputs | 4 |
Switching threshold "0" signal in reference to UN | ≤ 0.3 |
Switching threshold "1" signal in reference to UN | ≥ 0.7 |
Analog
Description of the input | Analog input |
Number of Inputs | 2 |
Input Signal | Current or voltage |
Resolution | 15 bit |
Input Impedance | 600 kΩ (Voltage inputs) |
Input Impedance | 50 Ω (Current inputs) |
Voltage input signal | 0 V DC ... 60 V DC |
Current Input Signal | 0 mA ... 20 mA |
Current Input Signal | 4 mA ... 20 mA (configurable) |
Precision | ± 0.1 % |
Switching
Output name | Relay output |
Number of Outputs | 4 |
Contact switching type | N/O contact |
Minimum Switching Voltage | 100 mV |
Maximum Switching Voltage | 60 V DC |
Maximum Switching Voltage | 30 V AC |
Limiting Continuous Current | 6 A |
Switching capacity | 100 W (Power Source PS2, Pout ≤100 W) |
Electrical service life | 30000 cycles |
Supply
Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 2.5 mm² |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 2.5 mm² |
Single conductor/terminal point, rigid | 0.2 mm² ... 2.5 mm² |
Single-wire/terminal point, flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section, flexible [AWG] | 24 ... 14 |
Stripping length | 6.50 mm |
Tightening torque | 0.5 Nm ... 0.6 Nm (5-7 lbs-in, screw terminal blocks) |
Data: USB 2.0
Connection Method | Mini-USB type B, 5-pos. |
Transmission length | ≤ 3 m (only for configuration and diagnostics) |
Wireless
Interface description | GSM / GPRS / EDGE / LTE (FDD) |
Frequency Range | 800 MHz (LTE B20) |
Frequency Range | 1800 MHz (LTE B3) |
Frequency Range | 2600 MHz (LTE B7) |
Frequency Range | 900 MHz (2 W (EGSM)) |
Frequency Range | 1800 MHz (1 W (EGSM)) |
GPRS | Multislot Class 33 |
EDGE | Multislot Class 33 |
LTE | CAT1 |
Dimensions
Width | 72 mm |
Height | 90 mm |
Depth | 62 mm |
Material specifications
Color (Upper housing part) | light grey (RAL 7035) |
Color (Lower housing part) | black (RAL 9005) |
Material (Housing) | Polycarbonate |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -25 °C ... 70 °C (SMS mode only, note the derating information in the technical documentation for data connection) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Altitude | 2000 m |
Permissible humidity (operation) | 0 % ... 95 % |
CE
Certificate | CE-compliant |
Wireless approval, Europe
Note | RED 2014/53/EU |
UKCA
Certificate | UKCA-compliant |
EMC data
Electromagnetic compatibility | Conformance with RED Directive 2014/53/EU |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Contact discharge | ± 6 kV |
Discharge in air | ± 8 kV |
Indirect discharge | ± 6 kV |
Comments | Criterion B |
Electromagnetic HF field
Standards/regulations | EN 61000-4-3 |
Frequency Range | 26 MHz ... 6 GHz |
Field intensity | 10 V/m |
Comments | Criterion A |
Fast transients (burst)
Standards/regulations | EN 61000-4-4 |
Input | ± 2 kV (Unshielded supply line) |
Signal | ± 2 kV (Shielded signal line) |
Signal | ± 2 kV (Analog I/O cables, unshielded) |
Comments | Criterion B |
Surge current load (surge)
Standards/regulations | EN 61000-4-5 |
Input | ± 0.5 kV (Symmetrical, unshielded supply line) |
Input | ± 0.5 kV (Asymmetrical, unshielded supply line) |
Signal | ± 1 kV (Data line, asymmetrical) |
Comments | Criterion B |
Conducted interference
Standards/regulations | EN 61000-4-6 |
Frequency Range | 0.15 MHz ... 80 MHz |
Comments | Criterion A |
Voltage | 10 V |
Emitted interference
Emitted radio interference in acc. with EN 55011 | Class B, area of application: Industry and residential |
Criteria
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Standards and Regulations
Standards/regulations | EN 50360 |
Standards/regulations | EN 50121-4 |
Mounting
Mounting Type | DIN rail mounting |
Mounting Type | Wall mounting |
Accessories
Why Proax for Phoenix Contact 1038567?
Proax is an authorized distributor of Phoenix Contact 1038567 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended