Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
1038567
Weight
0.24 kg

TC MOBILE I/O X200-4G - SMS relay

SMS relay and signaling module, European version, monitor analog and digital values via cellular network, switch relay outputs remotely, communication via SMS or cellular network data connection (e-mail transmission, app), supply voltage 10 V ... 60 V DC

  • Future-proof 4G technology (LTE CAT1), simultaneous use of well-established 2G networks (GSM, GPRS, EDGE)
  • Alerts via SMS in the field and, for example, via e-mail in the control room
  • Message chain for sending an alert to the relevant service technician
  • Alarm generation on voltage failure via SMS
  • Free switching via phone call
  • Cost control for prepaid cards
  • Remote commands to avoid on-site servicing: switching, configuration commands, and logbook transmission
  • Compact design also for domestic installations (4 HP, DIN 43880)
  • Mounting on DIN rail or on the wall
Technical Specifications

Product properties

ApplicationI/O
MTTF674 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
MTTF324 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
MTTF130 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)

Electrical properties

Mains typeCellular communication

Supply

Supply Voltage Range10 V DC ... 60 V DC
Typical current consumption50 mA (24 V DC)
Max. current consumption80 mA

Digital

Description of the inputDigital input
Number of Inputs4
Switching threshold "0" signal in reference to UN≤ 0.3
Switching threshold "1" signal in reference to UN≥ 0.7

Analog

Description of the inputAnalog input
Number of Inputs2
Input SignalCurrent or voltage
Resolution15 bit
Input Impedance600 kΩ (Voltage inputs)
Input Impedance50 Ω (Current inputs)
Voltage input signal0 V DC ... 60 V DC
Current Input Signal0 mA ... 20 mA
Current Input Signal4 mA ... 20 mA (configurable)
Precision± 0.1 %

Switching

Output nameRelay output
Number of Outputs4
Contact switching typeN/O contact
Minimum Switching Voltage100 mV
Maximum Switching Voltage60 V DC
Maximum Switching Voltage30 V AC
Limiting Continuous Current6 A
Switching capacity100 W (Power Source PS2, Pout ≤100 W)
Electrical service life30000 cycles

Supply

Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 2.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 2.5 mm²
Single conductor/terminal point, rigid0.2 mm² ... 2.5 mm²
Single-wire/terminal point, flexible0.2 mm² ... 2.5 mm²
Conductor cross section, flexible [AWG]24 ... 14
Stripping length6.50 mm
Tightening torque0.5 Nm ... 0.6 Nm (5-7 lbs-in, screw terminal blocks)

Data: USB 2.0

Connection MethodMini-USB type B, 5-pos.
Transmission length≤ 3 m (only for configuration and diagnostics)

Wireless

Interface descriptionGSM / GPRS / EDGE / LTE (FDD)
Frequency Range800 MHz (LTE B20)
Frequency Range1800 MHz (LTE B3)
Frequency Range2600 MHz (LTE B7)
Frequency Range900 MHz (2 W (EGSM))
Frequency Range1800 MHz (1 W (EGSM))
GPRSMultislot Class 33
EDGEMultislot Class 33
LTECAT1

Dimensions

Width72 mm
Height90 mm
Depth62 mm

Material specifications

Color (Upper housing part)light grey (RAL 7035)
Color (Lower housing part)black (RAL 9005)
Material (Housing)Polycarbonate

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-25 °C ... 70 °C (SMS mode only, note the derating information in the technical documentation for data connection)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude2000 m
Permissible humidity (operation)0 % ... 95 %

CE

CertificateCE-compliant

Wireless approval, Europe

NoteRED 2014/53/EU

UKCA

CertificateUKCA-compliant

EMC data

Electromagnetic compatibilityConformance with RED Directive 2014/53/EU

Electrostatic discharge

Standards/regulationsEN 61000-4-2
Contact discharge± 6 kV
Discharge in air± 8 kV
Indirect discharge± 6 kV
CommentsCriterion B

Electromagnetic HF field

Standards/regulationsEN 61000-4-3
Frequency Range26 MHz ... 6 GHz
Field intensity10 V/m
CommentsCriterion A

Fast transients (burst)

Standards/regulationsEN 61000-4-4
Input± 2 kV (Unshielded supply line)
Signal± 2 kV (Shielded signal line)
Signal± 2 kV (Analog I/O cables, unshielded)
CommentsCriterion B

Surge current load (surge)

Standards/regulationsEN 61000-4-5
Input± 0.5 kV (Symmetrical, unshielded supply line)
Input± 0.5 kV (Asymmetrical, unshielded supply line)
Signal± 1 kV (Data line, asymmetrical)
CommentsCriterion B

Conducted interference

Standards/regulationsEN 61000-4-6
Frequency Range0.15 MHz ... 80 MHz
CommentsCriterion A
Voltage10 V

Emitted interference

Emitted radio interference in acc. with EN 55011Class B, area of application: Industry and residential

Criteria

Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.

Standards and Regulations

Standards/regulationsEN 50360
Standards/regulationsEN 50121-4

Mounting

Mounting TypeDIN rail mounting
Mounting TypeWall mounting
Accessories

Why Proax for Phoenix Contact TC MOBILE I/O X200-4G?

Proax is an authorized distributor of Phoenix Contact TC MOBILE I/O X200-4G and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesTCMOBILEIOX2004G
Pack Size1
Recommended

Available for order