Official Distributor
SKU
MPN
TC MOBILE I/O X200 AC
Weight
0.252 kg
Series TC-MOBILE-I-O-X
TC MOBILE I/O X200 AC - SMS relay
SMS relay and signaling module, monitor digital values via cellular network and switch relay outputs remotely, communication via SMS and GPRS (e-mail transmission, app), supply voltage range 93 V ... 250 V AC.
- Notification via SMS on change of status at input
- SMS status query of all inputs and outputs
- SMS relay for remote control of outputs
- Alarm generation on voltage failure via SMS
- GSM mobile phone network: 850, 900, 1800, and 1900 MHz
- Switching of outputs for a predefined time
- Communication via SMS and e-mail
- Configuration via USB and web browser
- Compact design also for domestic installations (4 HP, DIN 43880)
- Mounting on DIN rail or on the wall
Technical Specifications
Utilization restriction
CCCex note | Use in potentially explosive areas is not permitted in China. |
Product properties
MTTF | 792 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
MTTF | 378 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) |
MTTF | 153 Years (SN 29500 standard, temperature 40°C, operating cycle 100%) |
Electrical properties
Maximum power dissipation for nominal condition | 5.145 W |
Mains type | Cellular communication |
Supply
Supply Voltage Range | 93 V AC ... 250 V AC (47.5 Hz ... 63 Hz) |
Typical current consumption | 15 mA (230 V AC) |
Max. current consumption | 25 mA |
Digital
Description of the input | Digital input |
Number of Inputs | 4 |
Switching level "0" signal | 0 V AC ... 50 V AC |
Switching level "1" signal | 90 V AC ... 250 V AC |
Switching
Output name | Relay output |
Number of Outputs | 4 |
Contact switching type | N/O contact |
Minimum Switching Voltage | 5 V |
Maximum Switching Voltage | 125 V DC |
Maximum Switching Voltage | 250 V AC |
Limiting Continuous Current | 5 A |
Switching capacity | 750 VA |
Electrical service life | 150000 cycles (5 A / 30 V DC) |
Electrical service life | 150000 cycles (3 A / 120 V AC) |
Electrical service life | 30000 cycles (5 A / 250 V AC) |
Supply
Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 2.5 mm² |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 2.5 mm² |
Conductor cross section, flexible | 0.20 mm² ... 2.50 mm² |
Conductor cross section, rigid | 0.20 mm² ... 2.50 mm² |
Conductor cross section AWG | 24 ... 14 |
Stripping length | 6.50 mm |
Tightening torque | 0.5 Nm ... 0.6 Nm (5-7 lbs-in, screw terminal blocks) |
Interfaces
Web server | yes |
Data: USB 2.0
Connection Method | Mini-USB type B, 5-pos. |
Transmission length | ≤ 3 m (only for configuration and diagnostics) |
Wireless
Interface description | GSM / GPRS |
Frequency Range | 850 MHz (2 W (EGSM)) |
Frequency Range | 900 MHz (2 W (EGSM)) |
Frequency Range | 1800 MHz (1 W (EGSM)) |
Frequency Range | 1900 MHz (1 W (EGSM)) |
GPRS | Multislot Class 10 |
Dimensions
Width | 72 mm |
Height | 90 mm |
Depth | 62 mm |
Material specifications
Color (Upper housing part) | light grey (RAL 7035) |
Color (Lower housing part) | black (RAL 9005) |
Material (Housing) | Polycarbonate |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -25 °C ... 70 °C (SMS mode only, note the derating information in the technical documentation for data connection) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Altitude | 2000 m |
Permissible humidity (operation) | 0 % ... 95 % |
CE
Certificate | CE-compliant |
ATEX
Identification | II 3 G Ex nA nC IIC T4 Gc X |
Note | Please follow the special installation instructions in the documentation! |
Wireless approval USA, FCC
Note | Part 15.107(a), 15.109(a) |
Corrosive gas test
Identification | ISA-S71.04-1985 G3 Harsh Group A |
Wireless approval, Europe
Note | RED 2014/53/EU |
EMC data
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Conducted noise emission | Class B, area of application: Industry and residential |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Contact discharge | ± 6 kV |
Discharge in air | ± 8 kV |
Indirect discharge | ± 6 kV |
Comments | Criterion B |
Electromagnetic HF field
Standards/regulations | EN 61000-4-3 |
Frequency Range | 26 MHz ... 6 GHz |
Field intensity | 10 V/m |
Comments | Criterion A |
Fast transients (burst)
Standards/regulations | EN 61000-4-4 |
Input | ± 2 kV (Unshielded supply line) |
Signal | ± 2 kV (Shielded signal line) |
Comments | Criterion B |
Surge current load (surge)
Standards/regulations | EN 61000-4-5 |
Input | ± 1 kV (Symmetrical, unshielded supply line) |
Input | ± 2 kV (Asymmetrical, unshielded supply line) |
Signal | ± 1 kV (Data line, asymmetrical) |
Comments | Criterion B |
Conducted interference
Standards/regulations | EN 61000-4-6 |
Frequency Range | 0.15 MHz ... 80 MHz |
Comments | Criterion A |
Voltage | 10 V |
Voltage dips
Standards/regulations | EN 61000-4-11 |
Emitted interference
Emitted radio interference in acc. with EN 55011 | Class B, area of application: Industry and residential |
Criteria
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Standards and Regulations
Standards/regulations | EN 50360 |
Standards/regulations | EN 50121-4 |
Mounting
Mounting Type | DIN rail mounting |
Accessories
Why Proax for Phoenix Contact 2903806?
Proax is an authorized distributor of Phoenix Contact 2903806 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended