TC MOBILE I/O X200 AC
Weight
0.252 kg

TC MOBILE I/O X200 AC - SMS relay

SMS relay and signaling module, monitor digital values via cellular network and switch relay outputs remotely, communication via SMS and GPRS (e-mail transmission, app), supply voltage range 93 V ... 250 V AC.

  • Notification via SMS on change of status at input
  • SMS status query of all inputs and outputs
  • SMS relay for remote control of outputs
  • Alarm generation on voltage failure via SMS
  • GSM mobile phone network: 850, 900, 1800, and 1900 MHz
  • Switching of outputs for a predefined time
  • Communication via SMS and e-mail
  • Configuration via USB and web browser
  • Compact design also for domestic installations (4 HP, DIN 43880)
  • Mounting on DIN rail or on the wall
Technical Specifications

Utilization restriction

CCCex noteUse in potentially explosive areas is not permitted in China.

Product properties

MTTF792 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
MTTF378 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
MTTF153 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)

Electrical properties

Maximum power dissipation for nominal condition5.145 W
Mains typeCellular communication

Supply

Supply Voltage Range93 V AC ... 250 V AC (47.5 Hz ... 63 Hz)
Typical current consumption15 mA (230 V AC)
Max. current consumption25 mA

Digital

Description of the inputDigital input
Number of Inputs4
Switching level "0" signal0 V AC ... 50 V AC
Switching level "1" signal90 V AC ... 250 V AC

Switching

Output nameRelay output
Number of Outputs4
Contact switching typeN/O contact
Minimum Switching Voltage5 V
Maximum Switching Voltage125 V DC
Maximum Switching Voltage250 V AC
Limiting Continuous Current5 A
Switching capacity750 VA
Electrical service life150000 cycles (5 A / 30 V DC)
Electrical service life150000 cycles (3 A / 120 V AC)
Electrical service life30000 cycles (5 A / 250 V AC)

Supply

Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 2.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 2.5 mm²
Conductor cross section, flexible0.20 mm² ... 2.50 mm²
Conductor cross section, rigid0.20 mm² ... 2.50 mm²
Conductor cross section AWG24 ... 14
Stripping length6.50 mm
Tightening torque0.5 Nm ... 0.6 Nm (5-7 lbs-in, screw terminal blocks)

Interfaces

Web serveryes

Data: USB 2.0

Connection MethodMini-USB type B, 5-pos.
Transmission length≤ 3 m (only for configuration and diagnostics)

Wireless

Interface descriptionGSM / GPRS
Frequency Range850 MHz (2 W (EGSM))
Frequency Range900 MHz (2 W (EGSM))
Frequency Range1800 MHz (1 W (EGSM))
Frequency Range1900 MHz (1 W (EGSM))
GPRSMultislot Class 10

Dimensions

Width72 mm
Height90 mm
Depth62 mm

Material specifications

Color (Upper housing part)light grey (RAL 7035)
Color (Lower housing part)black (RAL 9005)
Material (Housing)Polycarbonate

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-25 °C ... 70 °C (SMS mode only, note the derating information in the technical documentation for data connection)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude2000 m
Permissible humidity (operation)0 % ... 95 %

CE

CertificateCE-compliant

ATEX

Identification II 3 G Ex nA nC IIC T4 Gc X
NotePlease follow the special installation instructions in the documentation!

Wireless approval USA, FCC

NotePart 15.107(a), 15.109(a)

Corrosive gas test

IdentificationISA-S71.04-1985 G3 Harsh Group A

Wireless approval, Europe

NoteRED 2014/53/EU

EMC data

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Conducted noise emissionClass B, area of application: Industry and residential

Electrostatic discharge

Standards/regulationsEN 61000-4-2
Contact discharge± 6 kV
Discharge in air± 8 kV
Indirect discharge± 6 kV
CommentsCriterion B

Electromagnetic HF field

Standards/regulationsEN 61000-4-3
Frequency Range26 MHz ... 6 GHz
Field intensity10 V/m
CommentsCriterion A

Fast transients (burst)

Standards/regulationsEN 61000-4-4
Input± 2 kV (Unshielded supply line)
Signal± 2 kV (Shielded signal line)
CommentsCriterion B

Surge current load (surge)

Standards/regulationsEN 61000-4-5
Input± 1 kV (Symmetrical, unshielded supply line)
Input± 2 kV (Asymmetrical, unshielded supply line)
Signal± 1 kV (Data line, asymmetrical)
CommentsCriterion B

Conducted interference

Standards/regulationsEN 61000-4-6
Frequency Range0.15 MHz ... 80 MHz
CommentsCriterion A
Voltage10 V

Voltage dips

Standards/regulationsEN 61000-4-11

Emitted interference

Emitted radio interference in acc. with EN 55011Class B, area of application: Industry and residential

Criteria

Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.

Standards and Regulations

Standards/regulationsEN 50360
Standards/regulationsEN 50121-4

Mounting

Mounting TypeDIN rail mounting
Accessories

Why Proax for Phoenix Contact 2903806?

Proax is an authorized distributor of Phoenix Contact 2903806 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability