Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
SACCBP-FSD-4CON-PG9/4,0-936SCO
Weight
0.346 kg
This product is Not Cancellable/Not Returnable
Series SACCBP-FSD

SACCBP-FSD-4CON-PG9/4,0-936SCO - Bus system flush-type socket

Bus system flush-type socket, PROFINET, 4-pos., M12, shielded, D-coded, SPEEDCON, rear/screw mounting with Pg9 thread, with 4.0 m bus cable, 2 x 2 x 0.34 mm2

Technical Specifications

Product properties

Number of Positions4
No. of cable outlets1
CodingD

Insulation characteristics

Overvoltage categoryII
Degree of pollution3

Electrical properties

Nominal voltage UN250 V
Nominal current IN4 A

Material specifications

Flammability rating according to UL 94V0
Seal materialNBR
Contact MaterialCuZn
Contact surface materialNi/Au
Contact carrier materialPA 6.6
Material for screw connectionBrass, nickel-plated

Connection 1

Head designSocket
Head cable outletstraight
Head thread typeM12
CodingD

Connection 2

Head designfree cable end

Cable/line

Cable Length4 m

PROFINET RADOX® railway application CAT5 reinforced [936]

Shieldedyes
Cable weight81 g/m
Cable TypePROFINET RADOX® railway application CAT5 reinforced
Cable type (abbreviation)936
Signal type/categoryPROFINET CAT5 (IEC 11801), 100 Mbps
Cable structure1x4xAWG22/7, SF/TQ
External Cable Diameter7.25 mm ±0.3 mm
Outer sheath, materialPE-X
External sheath, colorblack RAL 9005
Thickness, outer sheath≥ 0.80 mm
Conductor materialsilver-plated Cu litz wires
Conductor structure signal line7x 0.25 mm
AWG Signal Line22
Conductor Cross Section4x 0.34 mm²
Material wire insulationPE-X
Wire diameter incl. insulation1.95 mm
Single wire, colorwhite-blue, orange-yellow
Overall twistStar quad
ShieldingPlastic-coated aluminum foil, tinned copper braided shield
Optical shield covering100 %
Nominal voltage, cable300 V AC
Test voltage, cable2000 V AC (50 Hz, 5 minutes)
Cable resistance≤ 54.4 Ω/km
Coupling resistance200.00 mΩ/m (f ≤ 30 MHz)
Wave impedance100 Ω ±5 Ω (f = 100 MHz)
Working capacitance≤ 65 pF (Line-line)
Working capacitance≤ 100 pF (Line-shield)
Signal speed66 c
Minimum bending radius, fixed installation6 x D
Minimum bending radius, flexible installation10 x D
Remote crosstalk attenuation (FEXT)80 dB (with 1 MHz)
Remote crosstalk attenuation (FEXT)70 dB (at 4 МHz)
Remote crosstalk attenuation (FEXT)65 dB (at 10 MHz)
Remote crosstalk attenuation (FEXT)58 dB (at 31.5 МHz)
Remote crosstalk attenuation (FEXT)59 dB (at 62.5 МHz)
Remote crosstalk attenuation (FEXT)67 dB (at 100 MHz)
Near end crosstalk attenuation (NEXT)80 dB (with 1 MHz)
Near end crosstalk attenuation (NEXT)76 dB (at 4 МHz)
Near end crosstalk attenuation (NEXT)67 dB (at 10 MHz)
Near end crosstalk attenuation (NEXT)60 dB (at 31.5 МHz)
Near end crosstalk attenuation (NEXT)56 dB (at 62.5 МHz)
Near end crosstalk attenuation (NEXT)53 dB (at 100 MHz)
Return attenuation (RL)35 dB (at 4 МHz)
Return attenuation (RL)35 dB (at 10 MHz)
Return attenuation (RL)35 dB (at 31.5 МHz)
Return attenuation (RL)33 dB (at 62.5 МHz)
Return attenuation (RL)33 dB (at 100 MHz)
Shield attenuation40.00 dB (30 MHz ≤ f ≤ 100 MHz)
Fire protection in rail vehiclesBS 6853 (Category Ia, Ib, II)
Fire protection in rail vehiclesGM/RT 2130 (Category Ia, Ib, II)
Fire protection in rail vehiclesEN 45545 (Risk level HL1 - HL3)
Fire protection in rail vehiclesDIN 5510 (Fire protection level 1, 2, 3, 4)
Fire protection in rail vehiclesNF F16-101 (Category A1, A2, B)
Fire protection in rail vehiclesNF F16-101 (Class C/F0)
Fire protection in rail vehiclesNFPA 130
Fire protection in rail vehiclesUNI CEI 11170 (Risk level LR1 - LR4)
Halogen-freein accordance with EN 50267-2-1
Resistance to Oilaccording to IRM 902, 72 h at 100 °C
Concentration of fumesBS 6853 D.8.7
Concentration of fumesEN 61034-2
Concentration of fumesUL 1685, 12 (FT4)
Fume toxicityBS 6853 B.1
Fume toxicityEN 50305, 9.2
Fume corrosivenessEN 50267-2-2
Flame resistanceEN 60332-1-2
Flame resistanceEN 50266
Flame resistanceEN 60332-3-25
Flame resistanceNF C32-070, 2.1
Flame resistanceNF C32-070, 2.2
Flame resistanceUL 1685, 12 (FT4)
Flame resistancein accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Other resistanceResistance to fuels (according to IRM 903, 168 h at 70 °C)
Ambient Temperature (Operation)-40 °C ... 90 °C (Cable, flexible installation)
Ambient Temperature (Operation)-50 °C ... 90 °C (cable, fixed installation)

Mechanical data

Insertion/withdrawal cycles≥ 100

Ambient conditions

Degree of ProtectionIP67 (When plugged in)
Degree of ProtectionIP65 (When plugged in)
Degree of ProtectionIP65/IP67
Ambient Temperature (Operation)-25 °C ... 70 °C (cable, fixed installation)
Ambient Temperature (Operation)-25 °C ... 70 °C (Cable, flexible installation)
Ambient Temperature (Operation)-5 °C ... 50 °C (Cable, flexible installation)

Why Proax for Phoenix Contact 1445732?

Proax is an authorized distributor of Phoenix Contact 1445732 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size100
Recommended
Sold in quantities of 100

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability