Official Distributor
By ABB
SKU
The AF52-30-00-41 is a 3 pole - 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 22 kW / 400 V AC (AC-3) or 40 hp / 480 V UL and switching power circuits up to 100 A (AC-1) or 80 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Technical Specifications
Dimensions
Product Net Width | 55 mm |
Product Net Depth / Length | 111 mm |
Product Net Height | 125.5 mm |
Product Net Weight | 0.97 kg |
Technical
Number of Main Contacts NO | 3 |
Number of Main Contacts NC | 0 |
Number of Auxiliary Contacts NO | 0 |
Number of Auxiliary Contacts NC | 0 |
Rated Operational Voltage | Main Circuit 690 V |
Rated Frequency (f) | Main Circuit 50 / 60 Hz |
Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 105 A |
Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 100 A, (690 V) 60 °C 80 A, (690 V) 70 °C 70 A |
Rated Operational Current AC-3 (Ie) | (415 V) 60 °C 53 A, (440 V) 60 °C 53 A, (500 V) 60 °C 45 A, (690 V) 60 °C 35 A, (380 / 400 V) 60 °C 53 A, (220 / 230 / 240 V) 60 °C 53 A |
Rated Operational Current AC-3e (Ie) | (415 V) 60 °C 53 A, (440 V) 60 °C 53 A, (500 V) 60 °C 45 A, (690 V) 60 °C 35 A, (380 / 400 V) 60 °C 53 A, (220 / 230 / 240 V) 60 °C 53 A |
Rated Operational Power AC-3 (Pe) | (400 V) 22 kW, (415 V) 30 kW, (440 V) 30 kW, (500 V) 30 kW, (690 V) 30 kW, (380 / 400 V) 22 kW, (220 / 230 / 240 V) 15 kW |
Rated Operational Power AC-3e (Pe) | (415 V) 30 kW, (440 V) 30 kW, (500 V) 30 kW, (690 V) 30 kW, (380 / 400 V) 22 kW, (220 / 230 / 240 V) 15 kW |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A, for 1 s -empty- A |
Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A |
Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour, (AC-2 / AC-4) 150 cycles per hour, (AC-3) 1200 cycles per hour |
Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V, acc. to UL/CSA 600 V |
Rated Impulse Withstand Voltage (Uimp) | 6 kV |
Maximum Mechanical Switching Frequency | 3600 cycles per hour |
Rated Control Circuit Voltage (Uc) | 50 Hz 24 ... 60 V, 60 Hz 24 ... 60 V, DC Operation - |
Operate Time | Between Coil De-energization and NC Contact Closing 19 ... 105 ms, Between Coil De-energization and NO Contact Opening 17 ... 100 ms, Between Coil Energization and NC Contact Opening 38 ... 95 ms, Between Coil Energization and NO Contact Closing 42 ... 100 ms |
Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715, TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
Mounting by Screws (not supplied) | 2 x M4 or 2 x M6 screws placed diagonally |
Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 4 ... 35 mm², Flexible with Insulated Ferrule 1/2x 4 ... 35 mm², Rigid 1/2x 6 ... 3 5 mm² |
Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm², Rigid 1/2x 1 ... 2.5 mm² |
Wire Stripping Length | Main Circuit 16 mm |
Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 |
Terminal Type | Screw Terminals |
Technical UL/CSA
General Use Rating UL/CSA | (600 V AC) 80 A |
Horsepower Rating UL/CSA | (120 V AC) Single Phase 3 hp, (200 ... 208 V AC) Three Phase 15 hp, (220 ... 240 V AC) Three Phase 20 hp, (240 V AC) Single Phase 10 hp, (440 ... 480 V AC) Three Phase 40 hp, (550 ... 600 V AC) Three Phase 50 hp |
Tightening Torque UL/CSA | Control Circuit 11 in·lb, Main Circuit 35 in·lb |
Environmental
Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C, Close to Contactor without Thermal O/L Relay -40 ... 70 °C, Close to Contactor for Storage -60 ... +80 °C |
Climatic Withstand | Category B according to IEC 60947-1 Annex Q |
Maximum Operating Altitude Permissible | Without Derating 3000 m |
Resistance to Vibrations acc. to IEC 60068-2-6 | 5 ... 300 Hz 3 g closed position / 3 g open position |
Resistance to Shock acc. to IEC 60068-2-27 | Closed, Shock Direction: A 25 g, Closed, Shock Direction: B1 25 g, Closed, Shock Direction: B2 15 g, Closed, Shock Direction: C1 25 g, Closed, Shock Direction: C2 25 g, Open, Shock Direction: B1 5 g |
RoHS Status | Following EU Directive 2011/65/EU |
Why Proax for ABB AF52-30-00-41?
Proax is an authorized distributor of ABB AF52-30-00-41 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate Names | AF52300041 |
Pack Size | 1 |
Recommended
- The AF52-40-00-41 is a 4 pole - 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 22 kW / 400 V AC (AC-3) and switching power circuits up to 100 A (AC-1) or 80 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.