1SBL367201R1300
The AF52-40-00-13 is a 4 pole - 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 22 kW / 400 V AC (AC-3) and switching power circuits up to 100 A (AC-1) or 80 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Technical Specifications

Dimensions

Product Net Width70 mm
Product Net Depth / Length113.5 mm
Product Net Height125.5 mm
Product Net Weight1.16 kg

Technical

Number of Main Contacts NO4
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC0
StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational VoltageMain Circuit 690 V
Rated Frequency (f)Control Circuit 50 / 60 Hz
Rated Frequency (f)Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 100 A
Rated Operational Current AC-1 (Ie)(690 V) 60 °C 80 A
Rated Operational Current AC-1 (Ie)(690 V) 70 °C 70 A
Rated Operational Current AC-3 (Ie)(415 V) 60 °C 53 A
Rated Operational Current AC-3 (Ie)(440 V) 60 °C 53 A
Rated Operational Current AC-3 (Ie)(500 V) 60 °C 45 A
Rated Operational Current AC-3 (Ie)(690 V) 60 °C 35 A
Rated Operational Current AC-3 (Ie)(380 / 400 V) 60 °C 53 A
Rated Operational Current AC-3 (Ie)(220 / 230 / 240 V) 60 °C 53 A
Rated Operational Power AC-3 (Pe)(415 V) 30 kW
Rated Operational Power AC-3 (Pe)(440 V) 30 kW
Rated Operational Power AC-3 (Pe)(500 V) 30 kW
Rated Operational Power AC-3 (Pe)(690 V) 30 kW
Rated Operational Power AC-3 (Pe)(380 / 400 V) 22 kW
Rated Operational Power AC-3 (Pe)(220 / 230 / 240 V) 15 kW
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 690 V
Rated Insulation Voltage (Ui)acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)6 kV
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 100 ... 250 V
Rated Control Circuit Voltage (Uc)60 Hz 100 ... 250 V
Rated Control Circuit Voltage (Uc)DC Operation 100 ... 250 V
Coil ConsumptionAverage Holding Value 50 / 60 Hz 4 V·A
Coil ConsumptionAverage Holding Value 50 Hz 4 V·A
Coil ConsumptionAverage Holding Value 60 Hz 4 V·A
Coil ConsumptionAverage Holding Value DC 2 W
Coil ConsumptionAverage Holding Value, from Warm State 2 W
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 4 ... 35 mm²
Connecting Capacity Main CircuitFlexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Connecting Capacity Main CircuitRigid Stranded 1/2x 6 ... 35 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Connecting Capacity Control CircuitRigid Solid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control CircuitRigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping LengthControl Circuit 10 mm
Wire Stripping LengthMain Circuit 16 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Terminal TypeScrew Terminals

Technical UL/CSA

Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(600 V AC) 80 A
Connecting Capacity Main Circuit UL/CSARigid Stranded 1/2x 10-2 AWG
Connecting Capacity Control Circuit UL/CSARigid Solid 1/2x 18-14 AWG
Connecting Capacity Control Circuit UL/CSARigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSAControl Circuit 11 in·lb
Tightening Torque UL/CSAMain Circuit 35 in·lb

Why Proax for ABB AF52-40-00-13?

Proax is an authorized distributor of ABB AF52-40-00-13 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesAF52400013
Pack Size1
Recommended

Available for order

ABB Availability