SKU
MPN
EV-RCM-C1-AC30-DC6
Weight
0.36 kg
EV-RCM-C1-AC30-DC6 - Differential current monitoring
The residual current module is used for AC and DC residual current detection in AC charging points. The higher-level safety equipment (e.g., residual current circuit breaker) is protected against potential DC residual currents. A 1 or 2-channel product version is available.
Technical Specifications
Product properties
Product family | CHARX control basic |
Application | Residual current monitoring module (RCM) for AC charging controllers for private applications (EU/CN) |
Type | 1-channel |
Operating elements | Test/reset button; 2 status LEDs |
Charging standard | Type 2 |
Charging mode | Mode 3 |
Charging controllers
Number of charging points | 1 |
Electrical properties
Type of charging current | AC 3-phase |
Current consumption | < 1 W |
Power consumption | < 5 VA |
Reload function | 3 switch-on attempts at intervals of 15 min. |
Measuring current transducer
Connection Method | Connector |
Supply | via RCM module |
Diameter of measuring coil | 15 mm |
Measuring range: Residual current
Rated frequency fn | ≤ 2000 Hz |
Nominal differential current | ± 300 mA (Peak) |
Measuring Range | 50 A (45 Hz ... 50 Hz) |
Residual current IΔn | 30 mA |
Residual current IΔn | 6 mA |
Rated current IN | 32 A |
Tripping time for IΔn | < 180 ms |
Response time for 2 x IΔn | < 70 ms |
Tripping time for 5xIΔn | < 20 ms |
Tripping time for IN | < 500 ms |
Supply
Supply Voltage Range | 100 V AC ... 240 V AC (nominal voltage range) |
Max. current consumption | 22 mA |
Nominal Power Consumption | < 0.5 W (No-load) |
Frequency Range | 45 Hz ... 60 Hz |
Digital
Description of the input | Plug-in; front |
Switching
Output name | Alarm relay 1 IΔn: DC residual currents |
Output name | Alarm relay 2 IΔn: AC residual currents |
Maximum Switching Voltage | 250 V |
Max. switching current | 5 A (1 N/O contact each) |
Number of contacts as N/O contacts | 1 |
Note regarding the switch contact | Quiescent current |
Switching cycles | 10000 |
Conductor connection
Connection Method | Spring-cage connection |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 14 |
Others
Number of interfaces | 1 (Measuring transducer) |
Transmission length | max. 100 m (with shielded, twisted-pair data cable) |
Number of interfaces | 2 (Error/Reset) |
Dimensions
Width | 36 mm |
Height | 90 mm |
Depth | 70.50 mm |
Ambient conditions
Degree of Protection | IP20 (Terminal blocks) |
Degree of Protection | IP30 (Inserts) |
Ambient Temperature (Operation) | -25 °C ... 80 °C |
Climatic class | according to IEC 60271/-1/-2/-3 |
Conformity/Approvals
Conformance | CE-compliant |
Standards
Standards/regulations | IEC 61851-1 |
Mounting
Mounting Position | any |
Accessories
- EV-CC-AC1-M3-CBC-SER-HS - The EV-CC-AC1-M3-CBC-SER-HS charging controller with housing for DIN rail mounting is used for charging electric vehicles at 3-phase AC networks according to IEC 61851-1, Mode 3. All charging functions, comprehensive configuration settings as well as a locking controller are already integrated.
- EV-CC-AC1-M3-CC-SER-HS - The EV-CC-AC1-M3-CBC-SER-HS charging controller with housing for DIN rail mounting is used for charging electric vehicles at 3-phase AC networks according to IEC 61851-1, Mode 3. Optimized for charging stations with permanently mounted Vehicle Connector. All charging functions and comprehensive configuration settings are already integrated.
- EV-CC-AC1-M3-CC-SER-PCB - The EV-CC-AC1-M3-CC-SER-PCB charging controller as a PCB for charging electric vehicles on a 3-phase AC power grid according to IEC 61851-1, Mode 3. Optimized for charging stations with permanently mounted Vehicle Connector. All charging functions and comprehensive configuration settings are already integrated.
Why Proax for Phoenix Contact 1622450?
Proax is an authorized distributor of Phoenix Contact 1622450 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |