Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
RIF-1-RSC-LV-120AC/1X21AU
Weight
0.071 kg
This product has been discontinued and replaced with 2903344
Series RIF

RIF-1-RSC-LV-120AC/1X21AU - Relay Module

Preassembled relay module with screw connection, consisting of: relay base, multi-layer contact relay, plug-in display/interference suppression module, and retaining bracket. Contact switching type: 1 changeover contact. Input voltage: 120 V AC

Technical Specifications

Notes

Notes on operationFBS 2-6... plug-in bridge for the input side (A2) and FBS-2-8... plug-in bridge for the output side (11/21)

Product properties

Product familyRIFLINE complete
ApplicationUniversal
Operating mode100% operating factor
Mechanical service lifeapprox. 107 cycles

Insulation characteristics

InsulationSafe isolation between input and output
InsulationBasic insulation between the changeover contacts
InsulationSafe isolation between input and output
InsulationBasic insulation between the changeover contacts
Overvoltage categoryIII
Pollution degree2

Electrical properties

Service life electricalsee diagram
Test voltage (Winding/contact)4 kVrms (50 Hz, 1 min., winding/contact)
Rated Insulation Voltage250 V AC
Rated surge voltage6 kV (Input/output)
Rated surge voltage4 kV (between the changeover contacts)

Coil side

Nominal input voltage UN120 V AC
Input voltage range96 V AC ... 138 V AC (20 °C)
Input voltage range in reference to UNsee diagram
Mains frequency50/60 Hz
Drive and functionmonostable
Typical input current at UN8 mA
Typical response time3 ms ... 12 ms
Typical release time range3 ms ... 20 ms
Coil Voltage120 V AC
Protective circuitVaristor
Operating voltage displayYellow LED

Switching

Contact switching type1 changeover contact
Type of switch contactSingle contact
Contact MaterialAgNi, hard gold-plated
Maximum Switching Voltage30 V AC
Maximum Switching Voltage36 V DC
Minimum Switching Voltage100 mV (at 10 mA)
Limiting Continuous Current50 mA
Maximum Inrush Current50 mA
Min. switching current1 mA (at 24 V)
Interrupting rating (ohmic load) max.1.2 W (24 V DC)
Utilization category CB Scheme (IEC 60947-5-1)AC15, 1.5 A/240 V (N/O contact)
Utilization category CB Scheme (IEC 60947-5-1)AC15, 3 A/250 V (N/C contact)
Utilization category CB Scheme (IEC 60947-5-1)DC13, 2 A/24 V (N/C contact)
Utilization category CB Scheme (IEC 60947-5-1)DC13, 0.2 A/250 V (N/O contact)

Switching: when the gold layer is destroyed

Notethe following values are applicable if a gold layer is destroyed
Contact MaterialAgNi
Maximum Switching Voltage250 V AC/DC
Minimum Switching Voltage12 V (at 10 mA)
Limiting Continuous Current25 A (20 ms, N/O contacts)
Min. switching current10 mA (at 12 V)
Interrupting rating (ohmic load) max.240 W (at 24 V DC)
Interrupting rating (ohmic load) max.58 W (at 48 V DC)
Interrupting rating (ohmic load) max.48 W (at 60 V DC)
Interrupting rating (ohmic load) max.50 W (at 110 V DC)
Interrupting rating (ohmic load) max.80 W (at 220 V DC)
Interrupting rating (ohmic load) max.2500 VA (for 250 V AC)
Switching capacity2 A (at 24 V, DC13)
Switching capacity0.2 A (at 110 V, DC13)
Switching capacity0.2 A (at 250 V, DC13)
Switching capacity2 A (at 24 V, AC15)
Switching capacity2 A (at 120 V, AC15)
Switching capacity2 A (at 250 V, AC15)

Connection data

Connection MethodScrew connection
Stripping length8 mm
Conductor cross section rigid0.5 mm² ... 4 mm²
Conductor cross-section rigid (2 conductors with same cross section)0.5 mm² ... 2.5 mm²
Conductor cross section flexible0.5 mm² ... 4 mm²
Conductor cross section flexible0.5 mm² ... 4 mm² (Ferrule with plastic sleeve)
Conductor cross section flexible (2 conductors with same cross section)0.5 mm² ... 2.5 mm²
Conductor cross section flexible (2 conductors with same cross section)0.5 mm² ... 1.5 mm² (TWIN ferrule with plastic sleeve)
Conductor cross section AWG20 ... 10 (solid)
Conductor cross section AWG20 ... 12 (flexible)
Tightening torque0.5 Nm ... 0.6 Nm

Dimensions

Width16 mm
Height89 mm
Depth75 mm

Material specifications

Colorgray (RAL 7042)
Flammability rating according to UL 94V2 (Housing)

Ambient conditions

Degree of protection (Relay base)IP20 (Relay base)
Degree of protection (Relay)RT II (Relay)
Ambient Temperature (Operation)-40 °C ... 50 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

Corrosive gas test

IdentificationISA-S71.04. G3 Harsh Group
IdentificationEN 60068-2-60

Standards and Regulations

Standards/regulationsDIN EN 50178

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsin rows with zero spacing
Mounting Positionany
Accessories

Why Proax for Phoenix Contact 2903352?

Proax is an authorized distributor of Phoenix Contact 2903352 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability