MACX MCR-SL-2NAM-T - Isolation amplifier

NAMUR 2-channel signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via transistor outputs (passive). Line fault detection, 3-way electrical isolation, SIL 2, screw connection.

  • Power supply and error indication possible via DIN rail connector
  • Installation in zone 2, protection type "n" (EN 60079-15) permitted
  • Up to SIL 2 in accordance with EN 61508
  • Line fault detection (LFD), can be activated/deactivated, error indicated by flashing red LED with disabling of transistor output
  • 2-channel
  • 3-way electrical isolation
  • Direction of operation can be selected (operating or closed circuit current behavior)
  • Input for NAMUR proximity sensors (EN 60947-5-6), floating contacts or contacts with resistance circuit
  • LED indicators for supply voltage, switching state, and malfunction in accordance with NAMUR NE 44
  • Transistor signal output (passive); up to 5 kHz
Technical Specifications

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area

Product properties

Product familyMACX Analog
ApplicationDigital IN
No. of channels2
TypeSignal conditioners with SIL functional safety
ConfigurationDIP switches

Insulation characteristics: GB Standard

Overvoltage categoryII
Pollution degree2

Functionality

ConfigurationDIP switches

Electrical properties

Electrical isolation3-way isolation
Electrical isolation between input and outputyes

Electrical isolation Input/output

Electrical isolation265 V (Peak value in accordance with IEC/EN 60079-7)

Electrical isolation Input/output/supply, DIN rail connector

Rated Insulation Voltage300 Vrms
Test voltage2.5 kV AC (50 Hz, 60 s)
InsulationSafe isolation in accordance with IEC/EN 61010-1

Electrical isolation Input/supply, DIN rail connector

Electrical isolation265 V (Peak value in accordance with IEC/EN 60079-7)

Electrical isolation Output 1/output 2

Rated Insulation Voltage50 Vrms
Test voltage1 kV AC (50 Hz, 60 s)
InsulationBasic insulation in accordance with IEC/EN 61010-1

Supply

Nominal Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30 V DC (24 V DC, -20 % ... +25 %)
Max. current consumption< 34 mA (24 V DC)
Power dissipation≤ 1000 mW
Power consumption0.8 W

Signal: NAMUR

Number of Inputs2
Available Input SourcesNAMUR proximity sensors (IEC/EN 60947-5-6)
Available Input SourcesFloating switch contacts
Available Input SourcesSwitch contacts with resistance circuit
Switching threshold "0" signal current< 1.2 mA (blocking)
Switching threshold "1" signal, current> 2.1 mA (conductive)
Short-circuit current8 mA
Switching hysteresis< 0.2 mA
Line fault detection< 0.05 mA ... 0.35 mA (Line break)
Line fault detection< 100 Ω ... 360 Ω (Short circuit)
Line fault detectionActivated /deactivated via DIP switch
Non-load voltage8 V DC

Switching: Transistor

Output descriptionpassive
Minimum Switching Voltage3 V DC
Maximum Switching Voltage30 V DC
Drop (ΔU)< 1.4 V
Max. switching current50 mA (short-circuit-proof)
Min. switching current5 mA (short-circuit-proof)
Switching frequency≤ 5 kHz

Signal

Number of Outputs2

Connection data

Connection MethodScrew connection
Stripping length7 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Tightening torque0.5 Nm ... 0.6 Nm

Test socket

Max. diameter2 mm

Ex data

Ex installation (EPL)Gc
Ex installation (EPL)Div. 2

Data

No. of channels0

Signaling

Status displayGreen LED (supply voltage)
Status displayLED yellow (switching state)
Status displayRed LED (line errors)

Dimensions

Width12.5 mm
Height112.5 mm
Depth113.7 mm
Depth NS 35/7,5114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715)

Material specifications

Colorgray (RAL 7042)
Flammability rating according to UL 94V0 (Housing)
Housing MaterialPA 6.6-FR

Safety data

Safety Integrity Level (SIL)2
Safety Integrity Level (SIL)2

Ambient conditions

Degree of ProtectionIP20 (not assessed by UL)
Ambient Temperature (Operation)-40 °C ... 70 °C (Any mounting position)
Ambient Temperature (Operation)-40 °C ... 70 °C (Derating)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)

Altitude range (≤ 2000 m)

Altitude≤ 2000 m (The technical data refers to altitudes ≤2000 m above mean sea level. For altitudes >2000 m above mean sea level, refer to the data sheet.)
Ambient Temperature (Operation)-40 °C ... 60 °C
Ambient Temperature (Operation)-40 °C ... 70 °C (Derating)
Rated Insulation Voltage265 V AC/DC (UIsolation “ec”: Supply, input / output)

Altitude range (≤ 3000 m)

Height Range> 2000 m ... 3000 m
Ambient Temperature (Operation)-40 °C ... 54 °C
Ambient Temperature (Operation)-40 °C ... 63 °C (Derating)
Rated Insulation Voltage190 V AC/DC (UIsolation “ec”: Supply, input / output)

Altitude range (≤ 4000 m)

Height Range> 3000 m ... 4000 m
Ambient Temperature (Operation)-40 °C ... 48 °C
Ambient Temperature (Operation)-40 °C ... 56 °C (Derating)
Rated Insulation Voltage60 V AC/DC (UIsolation “ec”: Supply, input / output)

Altitude range (≤ 5000 m)

Height Range> 4000 m ... 5000 m
Ambient Temperature (Operation)-40 °C ... 42 °C
Ambient Temperature (Operation)-40 °C ... 49 °C (Derating)
Rated Insulation Voltage60 V AC/DC (UIsolation “ec”: Supply, input / output)

CE

CertificateCE-compliant
Noteand EN 61326

ATEX

Identification II 3 G Ex ec IIC T4 Gc
CertificateIBExU 08 ATEX 1100 X

UKCA Ex (UKEX)

Identification II 3 G Ex ec IIC T4 Gc
CertificateCML 22UKEX3527X

IECEx

IdentificationEx ec IIC T4 Gc
CertificateIECEx IBE 08.0005X

CCC / China-Ex

IdentificationEx ec IIC T4 Gc
Certificate2022122310115713

UL, USA/Canada

IdentificationUL 508 Listed
IdentificationUL 61010 Listed
IdentificationClass I, Div. 2, Groups A, B, C, D T4
IdentificationClass I, Zone 2, Group IIC T4

Shipbuilding approval

CertificateDNV GL TAA00000AG

Safety Integrity Level (SIL, IEC 61508)

Identification2

INMETRO

IdentificationEx ec IIC T4 Gc
CertificateDNV 18.0141 X

EAC Ex

Identification 2Ex nA IIC T4 Gc
CertificateBY/112 02.01 TP012 103.01 00078

DNV GL data

TemperatureB
HumidityB
VibrationA
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Noise immunityEN 61000-6-2
Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4

Electromagnetic HF field

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Evaluation criterionA

Fast transients (burst)

DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Evaluation criterionA

Conducted interference

DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Evaluation criterionA

Standards and Regulations

Electrical isolation3-way isolation

GB Standard

Standards/regulationsGB 3836.1
Standards/regulationsGB 3836.3

Mounting

Mounting TypeDIN rail mounting
Accessories

Why Proax for Phoenix Contact 2865036?

Proax is an authorized distributor of Phoenix Contact 2865036 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability