Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
PT 2X2- 5DC-ST
Weight
0.026 kg
Series PT

PT 2X2- 5DC-ST - Surge protection plug

PT protective connector with protective circuit for two 2-wire floating signal circuits. 5 V DC nominal voltage. HART-compatible.

  • Easy testing and documentation with CHECKMASTER 2 with pluggable protective modules
  • Maximum ease of maintenance, thanks to the 2-piece design
  • Easy selection for all possible demands in MCR applications with a complete product portfolio
  • The signal is not influenced during maintenance work, thanks to the impedance-neutral insertion and removal of protective plugs

PT

The Phoenix Contact PT Series comprises feed-through terminal blocks that utilize Push-in connection technology, offering efficient and reliable wiring solutions for various industrial applications. These terminal blocks are designed for straightforward conductor insertion, enhancing installation speed and ensuring secure connections.

Key Features:

  • Push-in Connection Technology: The PT Series employs a direct plug-in method, allowing solid conductors or conductors with ferrules to be inserted easily without the need for tools. This design facilitates quick and reliable wiring.
  • Compact Design: The terminal blocks feature a space-saving form factor, making them suitable for applications where installation space is limited.
  • High Electrical Ratings: Depending on the specific model, the PT Series terminal blocks can handle nominal voltages up to 800 V and nominal currents up to 32 A, accommodating a wide range of electrical requirements.
  • Versatile Conductor Compatibility: These terminal blocks support various conductor types and sizes, providing flexibility in wiring configurations.
  • Integration with CLIPLINE Complete System: The PT Series is compatible with Phoenix Contact's CLIPLINE complete system, allowing for standardized bridging, marking, and testing accessories, which simplifies inventory management and enhances system modularity.
Technical Specifications

Product properties

Product familyPLUGTRAB PT
IEC test classificationC1
IEC test classificationC2
IEC test classificationC3
IEC test classificationD1
TypeMale
Surge protection fault messagenone
Arrester can be tested with CHECKMASTER from software version:From SW rev. 1.00
Wire pairs per module2

Insulation characteristics

Overvoltage categoryIII

Electrical properties

Nominal voltage UN5 V DC

Connection data

Connection MethodScrew connection (in connection with the base element)
Screw threadM3
Tightening torque0.8 Nm
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section rigid0.2 mm² ... 4 mm²
Conductor cross section AWG24 ... 12

Dimensions

Width17.5 mm
Height44.8 mm
Depth51.7 mm
Horizontal pitch1 Div.
Complete module width17.7 mm
Complete module height90 mm
Complete module depth65.5 mm

Material specifications

Colorblack (RAL 9005)
ColorCopper
Flammability rating according to UL 94V-0
Housing MaterialPA 6.6

Mechanical data

Open side panelNo

Protective circuit

Direction of actionLine-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Maximum continuous voltage UC6 V DC
Maximum continuous voltage UC4 V AC
Rated current450 mA (45 °C)
Operating effective current IC at UC≤ 1 mA
Residual current IPE≤ 1 µA (with PT 2X2+F-BE)
Residual current IPE≤ 4 µA
Nominal discharge current In (8/20) µs (line-line)10 kA
Nominal discharge current In (8/20) µs (line-ground)10 kA
Pulse discharge current Iimp (10/350) µs2.5 kA (per path)
Total discharge current Itotal (8/20) µs20 kA
Max. discharge current Imax (8/20) µs maximum (line-line)10 kA
Max. discharge current Imax (8/20) µs maximum (line-earth)10 kA
Output voltage limitation at 1 kV/µs (line-line) spike≤ 12 V
Output voltage limitation at 1 kV/µs (line-earth) spike≤ 450 V
Output voltage limitation at 1 kV/µs (line-line) static≤ 10 V
Residual voltage at In (conductor-conductor)≤ 10 V
Residual voltage at In (line-signalground)≤ 450 V
Residual voltage with Ian (10/1000) µs (line-line)≤ 12 V
Response time tA (line-line)≤ 1 ns
Response time tA (line-earth)≤ 100 ns
Input attenuation aE, sym.0.5 dB (≤ 200 kHz)
Cut-off frequency fg (3 dB), sym. in 50 Ω systemtyp. 1 MHz
Capacity (core-core)6 nF
Resistance per path2.2 Ω
Surge protection fault messagenone
Impulse durability (line-line)C2 - 10 kV / 5 kA
Impulse durability (line-earth)C2 - 10 kV / 5 kA
Impulse durability (line-earth)D1 - 2.5 kA

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-40 °C ... 85 °C

Air clearances and creepage distances

Standards/regulationsVDE 0110-1 / IEC 60664-1

Standards Information technology specification

Standards/regulationsIEC 61643-21
Standards/regulationsDIN EN 61643-21
Standards/regulationsUL 497B
Standards/regulationsIEC 61643-21
Standards/regulationsDIN EN 61643-21
Standards/regulationsUL 497B
Standards/specificationsIEC 61643-21
Note2000

Mounting

Mounting Typeon base element
Accessories

Why Proax for Phoenix Contact 2838241?

Proax is an authorized distributor of Phoenix Contact 2838241 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability