2302874
SKU
PHX2302874
MPN
FLKM 14-PA-AB/1756/IN/EXTC
Weight
0.06 kg
This product is Not Cancellable/Not Returnable
Series FLKM
FLKM 14-PA-AB/1756/IN/EXTC - Front adapter
VARIOFACE front adapter, for Allen Bradley ControlLogix and Honeywell PlantScape, input card IA 16, IB 16, IC 16, IN 16.The front adapters are pushed into the high 1756-TBE hoods (not supplied as standard).
Technical Specifications
Insulation characteristics
| Insulation | Functional insulation |
Insulation characteristics: Air clearances and creepage distances between the power circuits
| Insulation | Functional insulation |
| Overvoltage category | II |
| Pollution degree | 2 |
Electrical properties
| Operating voltage (AC) | ≤ 25 V AC |
| Operating voltage (DC) | ≤ 60 V DC |
| Nominal operating mode | 100% operating factor |
| Current (Per path) | ≤ 1 A |
Air clearances and creepage distances between the power circuits
| Rated Insulation Voltage | 63 V |
| Rated surge voltage | 0.6 kV |
Supported controller ALLEN-BRADLEY ControlLogix
| Suitable I/O card | 1756-IN16 |
| Suitable I/O card | 1756-IA16 |
| Suitable I/O card | 1756-IB16 |
| Suitable I/O card | 1756-IC16 |
Supported controller HONEYWELL Experion PKS C200
| Suitable I/O card | TC-IDA 161 |
Field level
| Connection Method | IDC/FLK pin strip |
| Number of Connections | 2 |
| Number of Positions | 14 |
| Pitch | 2.54 mm |
Supply
| Connection Method | Screw connection |
| Conductor cross section rigid | 0.14 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 1.5 mm² |
| Conductor cross section AWG | 28 ... 16 |
Item dimensions
| Width | 104.9 mm |
| Height | 33 mm |
| Depth | 40.84 mm |
Ambient conditions
| Degree of Protection | IP00 |
| Degree of protection (Installation location) | ≥ IP54 (Installation location) |
| Ambient Temperature (Operation) | -20 °C ... 50 °C |
| Ambient temperature (storage/transport) | -20 °C ... 70 °C |
| Altitude | ≤ 2000 m |
Air clearances and creepage distances between the power circuits
| Standards/regulations | DIN EN 50178 |
Mounting
| Assembly instructions | in rows with zero spacing |
| Mounting Position | any |
Notes
| Notes on operation | Do not connect adjacent channels to SELV/ PELV and voltages dangerous to the touch. |
| Notes on operation | No additional touch protection is required when using a SELV/PELV voltage (≤ 25 V AC or 60 V DC). |
| Notes on operation | At least one functional insulation against adjacent modules is complied with (in the support rail direction). If the application has stricter requirements for the insulation (basic insulation or reinforced insulation), they must be realized by applying suitable measures (e. g. partition plates). |
| Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
Accessories
Why Proax for Phoenix Contact 2302874?
Proax is an authorized distributor of Phoenix Contact 2302874 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |
Recommended