FLKM 14-PA-AB/1756/IF6I/EXTC - Adaptateur frontal
Adaptateurs VARIOFACE, pour ControlLogix d’Allen Bradley et PlantScape d’Honeywell.Les adaptateurs s’enfichent dans les capots hauts 1756-TBE (non compris dans la fourniture).
Technical Specifications
Insulation characteristics
Insulation | Functional insulation |
Insulation characteristics: Air clearances and creepage distances between the power circuits
Insulation | Functional insulation |
Overvoltage category | II |
Pollution degree | 2 |
Electrical properties
Operating voltage (AC) | ≤ 25 V AC |
Operating voltage (DC) | ≤ 60 V DC |
Nominal operating mode | 100% operating factor |
Current (Per path) | ≤ 1 A |
Air clearances and creepage distances between the power circuits
Rated Insulation Voltage | 63 V |
Rated surge voltage | 0.6 kV |
Field level
Connection Method | IDC/FLK pin strip |
Number of Connections | 2 |
Number of Positions | 14 |
Pitch | 2.54 mm |
Connection Method | Screw connection |
Conductor cross section rigid | 0.14 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.14 mm² ... 1.5 mm² |
Conductor cross section AWG | 28 ... 16 |
Ambient conditions
Degree of Protection | IP00 |
Degree of protection (Installation location) | ≥ IP54 (Installation location) |
Ambient Temperature (Operation) | -20 °C ... 50 °C |
Ambient temperature (storage/transport) | -20 °C ... 70 °C |
Altitude | ≤ 2000 m |
Air clearances and creepage distances between the power circuits
Standards/regulations | DIN EN 50178 |
Mounting
Assembly instructions | in rows with zero spacing |
Mounting Position | any |
Notes
Notes on operation | Do not connect adjacent channels to SELV/ PELV and voltages dangerous to the touch. |
Notes on operation | No additional touch protection is required when using a SELV/PELV voltage (≤ 25 V AC or 60 V DC). |
Notes on operation | At least one functional insulation against adjacent modules is complied with (in the support rail direction). If the application has stricter requirements for the insulation (basic insulation or reinforced insulation), they must be realized by applying suitable measures (e. g. partition plates). |
Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
Why Proax for Phoenix Contact 2901037?
Proax is an authorized distributor of Phoenix Contact 2901037 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended