HC-D 64-I-CT-M - Contact insert
Contact insert, number of positions: 64+PE, size: B24, number of connections per position: 1, Pin, Crimp connection, 250 V, 10 A, 0.14 mm2 ... 2.5 mm2, application: Signal
- Can be used in rail vehicles, satisfy DIN EN 45545-2 with requirement sets R22, R23, and R24 in hazard levels HL1, HL2, and HL3.
- For fast coding with plastic profile (Order No. 1410916, type CP-HC-S)
Technical Specifications
Notes
General | For HC-D64 housing, crimp contacts CK1,6-ED (crimp contacts not included in scope of supply) |
General | Connectors may be operated only when there is no load/voltage. |
General | It is imperative that guide pins (HC-CST) and sockets (HC-CBU) are used to prevent tip collision due to misalignment. |
General | This product replaces 1679498 HC-D 64-ESTC-R |
Mounting
Assembly instructions | To ensure correct use, installation in housing with IP54 protection or better is required |
Product properties
Series | HC-D |
Application | Signal |
Type | B24 |
Type | B48 |
Number of Positions | 64 |
Note number of positions | 64+PE |
Connection profile | 64+PE |
Number of connections per position | 1 |
Contact material type | turned |
Contact material type | rolled |
Insulation characteristics
Overvoltage category | III |
Degree of pollution | 3 |
Dimensions
Width | 34 mm |
Height | 32.8 mm |
Length | 110.5 mm |
Drill hole distance, horizontal | 104.5 mm |
Mechanical characteristics
Contact diameter | 1.6 mm |
Connection technology
Connection technology | Crimp connection |
Number of connections per position | 1 |
Connection in acc. with standard | IEC / EN |
Conductor connection
Conductor Cross Section | 0.14 mm² ... 2.5 mm² |
Connection cross section AWG | 26 ... 14 |
Tightening torque | 0.8 Nm ... 1.2 Nm (PE connection) |
Tightening torque | 0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing) |
Stripping length of the individual wire | 8 mm (0.14 mm² ... 1.5 mm²) |
Stripping length of the individual wire | 6 mm (2.5 mm²) |
Electrical properties
Rated voltage (III/3) | 250 V |
Rated surge voltage | 4 kV |
Rated current | 10 A |
SCCR | 5 kA (UL 2237) |
Mechanical data
Insertion/withdrawal cycles | ≥ 500 |
Material specifications
Flammability rating according to UL 94 | V0 |
Contact Material | Copper alloy |
Contact surface material | Ag (alternatively Au) |
Contact carrier material | PC |
Standards/regulations | PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |
Ambient conditions
Ambient Temperature (Operation) | -40 °C ... 125 °C (including heating up of contacts) |
Standards and Regulations
Constructional and testing regulations | DIN VDE 0627/86 |
Constructional and testing regulations | DIN VDE 0110/02.79 |
Constructional and testing regulations | DIN VDE 0110-1/04.97 |
Constructional and testing regulations | IEC 60664-1, DIN IEC 60512 |
Constructional and testing regulations | IEC 60352 |
Tests | DIN VDE 0627/86 |
Tests | DIN VDE 0110/02.79 |
Tests | DIN VDE 0110-1/04.97 |
Tests | IEC 60664-1, DIN IEC 60512 |
Tests | IEC 60352 |
Testing
Standards/regulations | PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |
Accessories
Why Proax for Phoenix Contact 1584431?
Proax is an authorized distributor of Phoenix Contact 1584431 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended