Official Distributor
SKU
Weight
0.504 kg
This product is Not Cancellable/Not Returnable
Series HC-D
HC-D 64-A-TWIN-PER-M - Terminal adapter
HEAVYCON terminal adapter male insert, D64 series, 64-pos., left PE connection for the right side of the control cabinet, push-in connection
- Easy installation without tools, even when mounted, with push-in connection technology
- Shortest installation time compared to other connection technologies
- Quick and effortless wiring, in particular when space is tight
- Automatic cabling with robots possible
- Safe wiring and operation with color-coded actuators
- Shock and vibration-resistant in accordance with DIN EN 61373
Technical Specifications
Notes
General | For HEAVYCON-ADVANCE mounting flange and HEAVYCON panel mounting base of B24 type |
General | Connectors may be operated only when there is no load/voltage. |
Product properties
Product family | HC-D |
Series | HC-D |
Application | Signal |
Type | B24 |
Number of Positions | 64 |
Connection profile | 64+PE |
No. of power contacts | 0 |
No. of control contacts | 64 |
Type | for the right side of the control cabinet |
Contact material type | rolled |
Insulation characteristics
Overvoltage category | III |
Degree of pollution | 3 |
Electrical properties
Rated voltage (III/3) | 250 V |
Rated surge voltage | 4 kV |
Rated current | 10 A |
SCCR | 5 kA (UL 2237) |
Connection technology
Connection technology | Push-in connection |
Conductor connection
Conductor Cross Section | 0.5 mm² ... 2.5 mm² (with ferrule) |
Connection cross section AWG | 22 ... 12 |
Stripping length of the individual wire | 10 mm |
Dimensions
Width | 34 mm |
Height | 139.3 mm |
Length | 110 mm |
Drill hole distance, horizontal | 104 mm |
Drill hole distance, vertical | 27 mm |
Mechanical characteristics
Contact diameter | 1.6 mm |
Material specifications
Flammability rating according to UL 94 | V0 |
Contact Material | Copper alloy |
Contact surface material | Ag |
Contact carrier material | PA |
Standards/regulations | PA: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |
Cable/line
Stripping length of the individual wire | 10 mm |
Mechanical data
Insertion/withdrawal cycles | ≥ 500 |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -40 °C ... 125 °C |
Standards and Regulations
Constructional and testing regulations | DIN EN 61984 |
Constructional and testing regulations | DIN EN 60664 |
Constructional and testing regulations | IEC 60352 |
Tests | DIN EN 61984 |
Tests | DIN EN 60664 |
Tests | IEC 60352 |
Testing
Standards/regulations | PA: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |
Mounting
Assembly instructions | To ensure correct use, installation in housing with IP54 protection or better is required |
Assembly instructions | Not for HC-EVO panel mounting bases |
Assembly instructions | Not for HC-EVO panel mounting bases |
Assembly instructions | Connectors may be plugged in only when there is no load/voltage. Not for HC-B 24-AMQ-EMV housings |
Accessories
Why Proax for Phoenix Contact 1580215?
Proax is an authorized distributor of Phoenix Contact 1580215 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended