AF140B-40-22RT-11
By ABB
SKU
ABBAF140B4022RT11
MPN
1SFL447262R1122
Weight
1.95 kg
A 4-pole Contactor suitable for Railway applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V. Operated with wide control voltage range 24-60 V, 50 and 60 Hz, 20-60 V DC
Technical Specifications
Dimensions
| Product Net Width | 120 mm |
| Product Net Depth / Length | 128 mm |
| Product Net Height | 150 mm |
| Product Net Weight | 1.95 kg |
Technical
| Number of Main Contacts NO | 4 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 2 |
| Number of Auxiliary Contacts NC | 2 |
| Number of Poles | 4P |
| Rated Operational Voltage | Main Circuit 1000 V |
| Rated Frequency (f) | Main Circuit 50 / 60 Hz |
| Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 200 A |
| Rated Operational Current AC-1 (Ie) | (690 V) 60 °C 175 A |
| Rated Operational Current AC-1 (Ie) | (690 V) 70 °C 160 A |
| Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 140 A |
| Rated Operational Current AC-3 (Ie) | (440 V) 55 °C 140 A |
| Rated Operational Current AC-3 (Ie) | (380 / 400 V) 55 °C 140 A |
| Rated Operational Current AC-3 (Ie) | (220 / 230 / 240 V) 55 °C 140 A |
| Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 40 °C 200 A |
| Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 60 °C 175 A |
| Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 70 °C 160 A |
| Rated Operational Current DC-1 (Ie) | (110 V) 3 Poles in Series, 40 °C 200 A |
| Rated Operational Current DC-1 (Ie) | (110 V) 3 Poles in Series, 60 °C 175 A |
| Rated Operational Current DC-1 (Ie) | (110 V) 3 Poles in Series, 70 °C 160 A |
| Rated Operational Current DC-1 (Ie) | (175 V) 2 Poles in Series, 40 °C 200 A |
| Rated Operational Current DC-1 (Ie) | (175 V) 2 Poles in Series, 60 °C 175 A |
| Rated Operational Current DC-1 (Ie) | (175 V) 2 Poles in Series, 70 °C 160 A |
| Rated Operational Current DC-1 (Ie) | (220 V) 3 Poles in Series, 40 °C 200 A |
| Rated Operational Current DC-1 (Ie) | (220 V) 3 Poles in Series, 60 °C 175 A |
| Rated Operational Current DC-1 (Ie) | (220 V) 3 Poles in Series, 70 °C 160 A |
| Rated Operational Current DC-1 (Ie) | (260 V) 3 Poles in Series, 40 °C 200 A |
| Rated Operational Current DC-1 (Ie) | (260 V) 3 Poles in Series, 60 °C 175 A |
| Rated Operational Current DC-1 (Ie) | (260 V) 3 Poles in Series, 70 °C 160 A |
| Rated Operational Current DC-1 (Ie) | (350 V) 4 Poles in Series, 40 °C 200 A |
| Rated Operational Current DC-1 (Ie) | (350 V) 4 Poles in Series, 60 °C 175 A |
| Rated Operational Current DC-1 (Ie) | (350 V) 4 Poles in Series, 70 °C 160 A |
| Rated Operational Current DC-1 (Ie) | (72 V) 1-Pole, 40 °C 200 A |
| Rated Operational Current DC-1 (Ie) | (72 V) 1-Pole, 60 °C 175 A |
| Rated Operational Current DC-1 (Ie) | (72 V) 1-Pole, 70 °C 160 A |
| Rated Operational Current DC-1 (Ie) | (72 V) 2 Poles in Series, 40 °C 200 A |
| Rated Operational Current DC-1 (Ie) | (72 V) 2 Poles in Series, 60 °C 175 A |
| Rated Operational Current DC-1 (Ie) | (72 V) 2 Poles in Series, 70 °C 160 A |
| Rated Operational Current DC-1 (Ie) | (72 V) 3 Poles in Series, 40 °C 200 A |
| Rated Operational Current DC-1 (Ie) | (72 V) 3 Poles in Series, 60 °C 175 A |
| Rated Operational Current DC-1 (Ie) | (72 V) 3 Poles in Series, 70 °C 160 A |
| Rated Operational Current DC-1 (Ie) | (90 V) 1 Pole, 40 °C 200 A |
| Rated Operational Current DC-1 (Ie) | (90 V) 1 Pole, 60 °C 175 A |
| Rated Operational Current DC-1 (Ie) | (90 V) 1 Pole, 70 °C 160 A |
| Rated Operational Current DC-3 (Ie) | (110 V) 2 Poles in Series, 40 °C 160 A |
| Rated Operational Current DC-3 (Ie) | (110 V) 2 Poles in Series, 60 °C 160 A |
| Rated Operational Current DC-3 (Ie) | (110 V) 2 Poles in Series, 70 °C 160 A |
| Rated Operational Current DC-3 (Ie) | (110 V) 3 Poles in Series, 40 °C 160 A |
| Rated Operational Current DC-3 (Ie) | (110 V) 3 Poles in Series, 60 °C 160 A |
| Rated Operational Current DC-3 (Ie) | (110 V) 3 Poles in Series, 70 °C 160 A |
| Rated Operational Current DC-3 (Ie) | (220 V) 3 Poles in Series, 40 °C 160 A |
| Rated Operational Current DC-3 (Ie) | (220 V) 3 Poles in Series, 60 °C 160 A |
| Rated Operational Current DC-3 (Ie) | (220 V) 3 Poles in Series, 70 °C 160 A |
| Rated Operational Current DC-3 (Ie) | (72 V) 2 Poles in Series, 40 °C 160 A |
| Rated Operational Current DC-3 (Ie) | (72 V) 2 Poles in Series, 60 °C 160 A |
| Rated Operational Current DC-3 (Ie) | (72 V) 2 Poles in Series, 70 °C 160 A |
| Rated Operational Current DC-3 (Ie) | (72 V) 3 Poles in Series, 40 °C 160 A |
| Rated Operational Current DC-3 (Ie) | (72 V) 3 Poles in Series, 60 °C 160 A |
| Rated Operational Current DC-3 (Ie) | (72 V) 3 Poles in Series, 70 °C 160 A |
| Rated Operational Current DC-5 (Ie) | (110 V) 2 Poles in Series, 40 °C 160 A |
| Rated Operational Current DC-5 (Ie) | (110 V) 2 Poles in Series, 60 °C 160 A |
| Rated Operational Current DC-5 (Ie) | (110 V) 2 Poles in Series, 70 °C 160 A |
| Rated Operational Current DC-5 (Ie) | (110 V) 3 Poles in Series, 40 °C 160 A |
| Rated Operational Current DC-5 (Ie) | (110 V) 3 Poles in Series, 60 °C 160 A |
| Rated Operational Current DC-5 (Ie) | (110 V) 3 Poles in Series, 70 °C 160 A |
| Rated Operational Current DC-5 (Ie) | (220 V) 3 Poles in Series, 40 °C 160 A |
| Rated Operational Current DC-5 (Ie) | (220 V) 3 Poles in Series, 60 °C 160 A |
| Rated Operational Current DC-5 (Ie) | (220 V) 3 Poles in Series, 70 °C 160 A |
| Rated Operational Current DC-5 (Ie) | (72 V) 2 Poles in Series, 40 °C 160 A |
| Rated Operational Current DC-5 (Ie) | (72 V) 2 Poles in Series, 60 °C 160 A |
| Rated Operational Current DC-5 (Ie) | (72 V) 2 Poles in Series, 70 °C 160 A |
| Rated Operational Current DC-5 (Ie) | (72 V) 3 Poles in Series, 40 °C 160 A |
| Rated Operational Current DC-5 (Ie) | (72 V) 3 Poles in Series, 60 °C 160 A |
| Rated Operational Current DC-5 (Ie) | (72 V) 3 Poles in Series, 70 °C 160 A |
| Rated Operational Power AC-3 (Pe) | (415 V) 75 kW |
| Rated Operational Power AC-3 (Pe) | (440 V) 90 kW |
| Rated Operational Power AC-3 (Pe) | (500 V) 90 kW |
| Rated Operational Power AC-3 (Pe) | (690 V) 75 kW |
| Rated Operational Power AC-3 (Pe) | (380 / 400 V) 75 kW |
| Rated Operational Power AC-3 (Pe) | (220 / 230 / 240 V) 37 kW |
| Rated Breaking Capacity AC-3e | 8.5 x Ie AC-3e |
| Rated Making Capacity AC-3 | 10 x Ie AC-3 |
| Rated Making Capacity AC-3e | 12 x Ie AC-3e |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 200 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 674 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1460 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1168 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 477 A |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
| Rated Insulation Voltage (Ui) | acc. to UL/CSA 600 V |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| Maximum Electrical Switching Frequency | (AC-3) 300 cycles per hour |
| Mechanical Durability | 5 million |
| Maximum Mechanical Switching Frequency | 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (Uc) | 50 Hz / 60 Hz 24 ... 60 V |
| Rated Control Circuit Voltage (Uc) | DC Operation 20 ... 60 V |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 5.5 V·A |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 60 Hz 5.5 V·A |
| Coil Consumption | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 225 V·A |
| Coil Consumption | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 225 V·A |
| Coil Consumption | Pull-in at Max. Rated Control Circuit Voltage DC 210 V·A |
| Coil Consumption | Pull-in at Max. Rated Control Circuit Voltage DC 210 W |
| Power Loss | 18 W |
| Power Loss | at Rated Operating Conditions per Pole 18 W |
| Connecting Capacity Main Circuit | Flexible 2 x 10 ... 70 mm² |
| Connecting Capacity Main Circuit | Rigid Cu-Cable 2 x 10 ... 95 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 2x 0.75 ... 2.5 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible 2x0.75 ... 2.5 mm² |
| Connecting Capacity Auxiliary Circuit | Solid 2 x 1 ... 4 mm² |
| Connecting Capacity Auxiliary Circuit | Stranded 2 x 1 .... 4 mm² |
| Connecting Capacity | Flexible 2 x 10 ... 70 mm² |
| Connecting Capacity | Rigid Cu-Cable 2 x 10 ... 95 mm² |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40 |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
| Tightening torque | Cable Lug 9 N·m |
| Terminal Type | Main Circuit: Bars |
| Product Name | Block Contactor |
Technical UL/CSA
| NEMA Size | 4 |
| Continuous Current Rating NEMA | 135 A |
| Horsepower Rating NEMA | (200 V AC) Three Phase 40 Hp |
| Horsepower Rating NEMA | (230 V AC) Three Phase 50 Hp |
| Horsepower Rating NEMA | (460 V AC) Three Phase 100 Hp |
| Horsepower Rating NEMA | (575 V AC) Three Phase 100 Hp |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| General Use Rating UL/CSA | (600 V AC) 175 A |
| Horsepower Rating UL/CSA | (200 ... 208 V AC) Three Phase 15 Hp |
| Horsepower Rating UL/CSA | (200 V AC) Three Phase 40 hp |
| Horsepower Rating UL/CSA | (208 V AC) Three Phase 40 hp |
| Horsepower Rating UL/CSA | (220 ... 240 V AC) Three Phase 20 Hp |
| Horsepower Rating UL/CSA | (220 ... 240 V AC) Three Phase 50 hp |
| Horsepower Rating UL/CSA | (440 ... 480 V AC) Three Phase 40 Hp |
| Horsepower Rating UL/CSA | (440 ... 480 V AC) Three Phase 100 hp |
| Horsepower Rating UL/CSA | (550 ... 600 V AC) Three Phase 50 Hp |
| Horsepower Rating UL/CSA | (550 ... 600 V AC) Three Phase 125 hp |
ABB EcoSolutions
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility |
| End Of Life Disassembling Instructions | 1SFC100112M0001 |
| Environmental Product Declaration - EPD | 1SFC100092D0201 |
| Improved Energy Efficiency for Customers | Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 87.8 % |
| Sustainable Material Content in Product (wt. %) | Recycled Metal - 37 % |
Why Proax for ABB AF140B-40-22RT-11?
Proax is an authorized distributor of ABB AF140B-40-22RT-11 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.