Proax
CADEN
proax logo
Cart

AF140B-40-22RT-13

ABBOfficial Distributor

By ABB

SKU
ABBAF140B4022RT13
MPN
1SFL447262R1322
Weight
1.95 kg
A 4-pole Contactor suitable for Railway applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V. Operated with wide control voltage range 100-250 V, 50 /60 Hz and DC
Technical Specifications

Dimensions

Product Net Width120 mm
Product Net Depth / Length128 mm
Product Net Height150 mm
Product Net Weight1.95 kg

Technical

Number of Main Contacts NO4
Number of Main Contacts NC0
Number of Auxiliary Contacts NO2
Number of Auxiliary Contacts NC2
Number of Poles4P
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 200 A
Rated Operational Current AC-1 (Ie)(690 V) 60 °C 175 A
Rated Operational Current AC-1 (Ie)(690 V) 70 °C 160 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 140 A
Rated Operational Current AC-3 (Ie)(440 V) 55 °C 140 A
Rated Operational Current AC-3 (Ie)(380 / 400 V) 55 °C 140 A
Rated Operational Current AC-3 (Ie)(220 / 230 / 240 V) 55 °C 140 A
Rated Operational Current DC-1 (Ie)(110 V) 2 Poles in Series, 40 °C 200 A
Rated Operational Current DC-1 (Ie)(110 V) 2 Poles in Series, 60 °C 175 A
Rated Operational Current DC-1 (Ie)(110 V) 2 Poles in Series, 70 °C 160 A
Rated Operational Current DC-1 (Ie)(110 V) 3 Poles in Series, 40 °C 200 A
Rated Operational Current DC-1 (Ie)(110 V) 3 Poles in Series, 60 °C 175 A
Rated Operational Current DC-1 (Ie)(110 V) 3 Poles in Series, 70 °C 160 A
Rated Operational Current DC-1 (Ie)(175 V) 2 Poles in Series, 40 °C 200 A
Rated Operational Current DC-1 (Ie)(175 V) 2 Poles in Series, 60 °C 175 A
Rated Operational Current DC-1 (Ie)(175 V) 2 Poles in Series, 70 °C 160 A
Rated Operational Current DC-1 (Ie)(220 V) 3 Poles in Series, 40 °C 200 A
Rated Operational Current DC-1 (Ie)(220 V) 3 Poles in Series, 60 °C 175 A
Rated Operational Current DC-1 (Ie)(220 V) 3 Poles in Series, 70 °C 160 A
Rated Operational Current DC-1 (Ie)(260 V) 3 Poles in Series, 40 °C 200 A
Rated Operational Current DC-1 (Ie)(260 V) 3 Poles in Series, 60 °C 175 A
Rated Operational Current DC-1 (Ie)(260 V) 3 Poles in Series, 70 °C 160 A
Rated Operational Current DC-1 (Ie)(350 V) 4 Poles in Series, 40 °C 200 A
Rated Operational Current DC-1 (Ie)(350 V) 4 Poles in Series, 60 °C 175 A
Rated Operational Current DC-1 (Ie)(350 V) 4 Poles in Series, 70 °C 160 A
Rated Operational Current DC-1 (Ie)(72 V) 1-Pole, 40 °C 200 A
Rated Operational Current DC-1 (Ie)(72 V) 1-Pole, 60 °C 175 A
Rated Operational Current DC-1 (Ie)(72 V) 1-Pole, 70 °C 160 A
Rated Operational Current DC-1 (Ie)(72 V) 2 Poles in Series, 40 °C 200 A
Rated Operational Current DC-1 (Ie)(72 V) 2 Poles in Series, 60 °C 175 A
Rated Operational Current DC-1 (Ie)(72 V) 2 Poles in Series, 70 °C 160 A
Rated Operational Current DC-1 (Ie)(72 V) 3 Poles in Series, 40 °C 200 A
Rated Operational Current DC-1 (Ie)(72 V) 3 Poles in Series, 60 °C 175 A
Rated Operational Current DC-1 (Ie)(72 V) 3 Poles in Series, 70 °C 160 A
Rated Operational Current DC-1 (Ie)(90 V) 1 Pole, 40 °C 200 A
Rated Operational Current DC-1 (Ie)(90 V) 1 Pole, 60 °C 175 A
Rated Operational Current DC-1 (Ie)(90 V) 1 Pole, 70 °C 160 A
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 40 °C 160 A
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 60 °C 160 A
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 70 °C 160 A
Rated Operational Current DC-3 (Ie)(110 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Current DC-3 (Ie)(110 V) 3 Poles in Series, 60 °C 160 A
Rated Operational Current DC-3 (Ie)(110 V) 3 Poles in Series, 70 °C 160 A
Rated Operational Current DC-3 (Ie)(220 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Current DC-3 (Ie)(220 V) 3 Poles in Series, 60 °C 160 A
Rated Operational Current DC-3 (Ie)(220 V) 3 Poles in Series, 70 °C 160 A
Rated Operational Current DC-3 (Ie)(72 V) 2 Poles in Series, 40 °C 160 A
Rated Operational Current DC-3 (Ie)(72 V) 2 Poles in Series, 60 °C 160 A
Rated Operational Current DC-3 (Ie)(72 V) 2 Poles in Series, 70 °C 160 A
Rated Operational Current DC-3 (Ie)(72 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Current DC-3 (Ie)(72 V) 3 Poles in Series, 60 °C 160 A
Rated Operational Current DC-3 (Ie)(72 V) 3 Poles in Series, 70 °C 160 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 40 °C 160 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 60 °C 160 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 70 °C 160 A
Rated Operational Current DC-5 (Ie)(110 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Current DC-5 (Ie)(110 V) 3 Poles in Series, 60 °C 160 A
Rated Operational Current DC-5 (Ie)(110 V) 3 Poles in Series, 70 °C 160 A
Rated Operational Current DC-5 (Ie)(220 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Current DC-5 (Ie)(220 V) 3 Poles in Series, 60 °C 160 A
Rated Operational Current DC-5 (Ie)(220 V) 3 Poles in Series, 70 °C 160 A
Rated Operational Current DC-5 (Ie)(72 V) 2 Poles in Series, 40 °C 160 A
Rated Operational Current DC-5 (Ie)(72 V) 2 Poles in Series, 60 °C 160 A
Rated Operational Current DC-5 (Ie)(72 V) 2 Poles in Series, 70 °C 160 A
Rated Operational Current DC-5 (Ie)(72 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Current DC-5 (Ie)(72 V) 3 Poles in Series, 60 °C 160 A
Rated Operational Current DC-5 (Ie)(72 V) 3 Poles in Series, 70 °C 160 A
Rated Operational Power AC-3 (Pe)(415 V) 75 kW
Rated Operational Power AC-3 (Pe)(440 V) 90 kW
Rated Operational Power AC-3 (Pe)(500 V) 90 kW
Rated Operational Power AC-3 (Pe)(690 V) 75 kW
Rated Operational Power AC-3 (Pe)(380 / 400 V) 75 kW
Rated Operational Power AC-3 (Pe)(220 / 230 / 240 V) 37 kW
Rated Breaking Capacity AC-3e8.5 x Ie AC-3e
Rated Making Capacity AC-310 x Ie AC-3
Rated Making Capacity AC-3e12 x Ie AC-3e
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 200 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 674 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1460 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1168 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 477 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Insulation Voltage (Ui)acc. to UL/CSA 600 V
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
Maximum Electrical Switching Frequency(AC-3) 300 cycles per hour
Mechanical Durability5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz / 60 Hz 100 ... 250 V
Rated Control Circuit Voltage (Uc)DC Operation 100 ... 250 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 6 V·A
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 60 Hz 6 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage 50 Hz 130 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage 60 Hz 130 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage DC 135 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage DC 135 W
Power Loss18 W
Power Lossat Rated Operating Conditions per Pole 18 W
Connecting Capacity Main CircuitFlexible 2 x 10 ... 70 mm²
Connecting Capacity Main CircuitRigid Cu-Cable 2 x 10 ... 95 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 2x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible 2x0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitSolid 2 x 1 ... 4 mm²
Connecting Capacity Auxiliary CircuitStranded 2 x 1 .... 4 mm²
Connecting CapacityFlexible 2 x 10 ... 70 mm²
Connecting CapacityRigid Cu-Cable 2 x 10 ... 95 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening torqueCable Lug 9 N·m
Terminal TypeMain Circuit: Bars
Product NameBlock Contactor

Technical UL/CSA

NEMA Size4
Continuous Current Rating NEMA135 A
Horsepower Rating NEMA(200 V AC) Three Phase 40 Hp
Horsepower Rating NEMA(230 V AC) Three Phase 50 Hp
Horsepower Rating NEMA(460 V AC) Three Phase 100 Hp
Horsepower Rating NEMA(575 V AC) Three Phase 100 Hp
Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(600 V AC) 175 A
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 15 Hp
Horsepower Rating UL/CSA(200 V AC) Three Phase 40 hp
Horsepower Rating UL/CSA(208 V AC) Three Phase 40 hp
Horsepower Rating UL/CSA(220 ... 240 V AC) Three Phase 20 Hp
Horsepower Rating UL/CSA(220 ... 240 V AC) Three Phase 50 hp
Horsepower Rating UL/CSA(440 ... 480 V AC) Three Phase 40 Hp
Horsepower Rating UL/CSA(440 ... 480 V AC) Three Phase 100 hp
Horsepower Rating UL/CSA(550 ... 600 V AC) Three Phase 50 Hp
Horsepower Rating UL/CSA(550 ... 600 V AC) Three Phase 125 hp

ABB EcoSolutions

ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetNon-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions1SFC100112M0001
Environmental Product Declaration - EPD1SFC100092D0201
Improved Energy Efficiency for CustomersProduct Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Sustainable Material Content in Product (wt. %)Recycled Metal - 37 %

Why Proax for ABB AF140B-40-22RT-13?

Proax is an authorized distributor of ABB AF140B-40-22RT-13 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate NamesAF140B4022RT13
Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

ABB Availability