Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
PSR-M-B2-SDI8-SDO4-DO4-PI
Weight
0.182 kg
This product is Not Cancellable/Not Returnable
Series PSR-M-B

PSR-M-B2-SDI8-SDO4-DO4-PI - Safety module

Configurable safety module (basic module), 8 safe inputs, 4 safe outputs, 4 reset inputs or 4 signal outputs, 4 clock outputs, can be extended via TBUS, up to SIL 3, Cat. 4/PL e, plug-in Push-in terminal block, TBUS connector not included

  • Cost-effective safety solution with a high level of adaptability to individual requirements
  • Fast startup, thanks to easy hardware and software configuration
  • Machine downtimes minimized with comprehensive, easy-to-understand diagnostics
  • Flexible extension with safe inputs and outputs
  • Possibility of connecting fieldbus gateways for bidirectional communication between the base module and the higher-level controller
  • Narrow housing width of just 22.6 mm
  • Tool-free and time-saving installation thanks to Push-in technology
  • Up to Cat. 4/PL e in accordance with EN ISO 13849-1, SIL 3 in accordance with EN IEC 62061, SIL 3 in accordance with IEC 61508
  • Suitable for elevator applications in accordance with EN 81-20
Technical Specifications

Product properties

ApplicationEmergency stop
ApplicationLight grid
ApplicationSafety door
ApplicationSafe shutdown

Insulation characteristics

Protection classIII (EN 50178)

Times

Response timesee user manual
Restart timemin. 5 s (Boot time)
Restart timemax. 10 s (Boot time)

Electrical properties

Maximum power dissipation for nominal condition7.1 W (with max. permissible load)
Nominal operating mode100% operating factor
InterfacesDIN rail TBUS for connection to the master module, not supplied as standard

Air clearances and creepage distances between the power circuits

Rated Insulation Voltage250 V AC
Rated surge voltage/insulationBasic insulation 4 kV between all current paths and housing

Supply

DesignationA1/A2
Rated control circuit supply voltage US19.2 V DC ... 28.8 V DC
Rated control circuit supply voltage US24 V DC -20 % / +20 % (provide external protection, typically 5 A)
Rated control supply current IStyp. 55 mA (Outputs inactive)
Rated control supply current IStyp. 135 mA (Outputs active, without load)
Power consumption at UStyp. 1.32 W (Outputs inactive)
Inrush Current< 2.3 A (Δt = 1 ms at Us)
Filter timetyp. 5 ms (at A1 in the event of voltage dips at Us)
Protective circuitSerial protection against polarity reversal

Digital: IN1, IN2, IN3, IN4, IN5, IN6, IN7, IN8

Description of the inputSafety-related digital inputs
Description of the inputIEC 61131-2 type 2
Number of Inputs8
Input voltage range "0" signal0 V DC ... 5 V DC
Input voltage range "1" signal11 V DC ... 28.8 V DC
Input current range "0" signal< 1 mA
Filter timemin. 3 ms ±2 ms (adjustable)
Filter timemax. 250 ms ±2 ms (adjustable)
Filter timeTest pulse rate ≥ 2x set filter time, min. Test pulse rate = 10 ms
Cable Lengthmax. 100 m (per input)
Max. permissible overall conductor resistancemax. 1.2 kΩ (Input and reset circuit at US)
Current consumptiontyp. 10 mA (typically with US)
Current consumptionmax. 12.1 mA (at a control voltage of 28.8 V DC)

Digital: Reset inputs (FBK)

Description of the inputconfigurable (as signal output or reset input)
Description of the inputIEC 61131-2 Type 2
Number of Inputs4
Input voltage range "0" signal0 V DC ... 5 V DC
Input voltage range "1" signal11 V DC ... 28.8 V DC
Input current range "0" signal< 1 mA
Filter time250 ms ±2 ms (Test pulse rate > 500 ms)
Cable Lengthmax. 100 m (per input)
Max. permissible overall conductor resistance1.2 kΩ (Input and reset circuit at US)
Current consumptiontyp. 12 mA (typically with US)
Current consumptionmax. 14.7 mA (at a control voltage of 28.8 V DC)

Digital: O1, O2, O3, O4

Output descriptionSafety-related digital outputs
Output descriptionPNP, OSSD
Output descriptionIEC 61131-2 type 0.5 (observe limiting continuous current)
Number of Outputs4
Protective circuitSuppressor diode
Short-circuit protectionYes (max. permissible short-circuit current 12 A)
Leakage currentmax. 250 µA
Cable Lengthmax. 100 m (per output)
Ohmic loadmin. 50 Ω (Observe limiting continuous current)
Max. capacitive loadmax. 820 nF
Max. inductive loadmax. 2.4 mH
Limiting Continuous Current400 mA (per channel)
Limiting Continuous Current1.6 A (Total current of all safe digital outputs)
Inrush Currentmax. 600 mA (Δt < 10 ms)
Nominal Output Voltage24 V DC (Supply via A1)
Nominal output voltage range18.5 V DC ... 28.1 V DC (US - 0,7 V)
Switching frequencymax. 1/4 x tCycle [Hz]
Output voltage when switched off< 0.1 V
Test pulses< 120 µs (Test pulse width of low test pulses)
Test pulses≥ 650 ms (Test pulse rate for low test pulse)
Test pulses< 150 µs (Test pulse width, high test pulse)
Test pulses≥ 1.5 s (Test pulse rate, high test pulse)
Discharging circuitYes, internal

Signal: MO1, MO2, MO3, MO4

Output descriptionPNP, IEC 61131-2 Typ 0,1
Output descriptionnon-safety-related, configurable (as signal output or reset input)
Number of Outputs4
Output voltage when switched offmax. 0.1 V
Voltage24 V DC (via A1)
Maximum Inrush Current1.1 A (Δt = 3 s  at Us)
Limiting Continuous Current100 mA (per channel)
Limiting Continuous Current400 mA (Total current of all digital signal outputs)
Leakage currentmax. 100 µA
Switching frequencymax. 1/4 x tCycle [Hz]
Protective circuitSuppressor diode
Short-circuit protectionYes (self-limitation at 1.1 A)
Cable Lengthmax. 100 m (per output)

Clock: T1, T2, T3, T4

Output descriptionPNP, IEC 61131-2 Typ 0,1
Number of Outputs4
Voltage24 V DC (via A1)
Output voltage when switched offmax. 0.1 V
Maximum Inrush Current1.1 A (Δt = 3 s  at Us)
Limiting Continuous Current100 mA (per channel)
Limiting Continuous Current400 mA (Total current of all outputs)
Leakage currentmax. 100 µA
Test pulses≤ 200 µs (Test pulse duration)
Test pulsesTest pulse rate = 8 x tCycle [ms]
Short-circuit protectionYes (self-limitation at 1.1 A)
Cable Lengthmax. 100 m (per output)
Max. capacitive loadmax. 470 nF
Max. inductive loadmax. 2.4 mH
Discharging circuitYes, internal

Connection technology

pluggableyes

Conductor connection

Connection MethodPush-in connection
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross-section AWG24 ... 14
Stripping length10 mm

Signaling

Status display1 x LED (green), 1 x LED (orange), 1 x LED (blue)
Status display4 x LED (green, yellow, red)
Status display12 x LED (yellow)
Operating voltage display1 x green LED
Error indication2 x LED (red)

Dimensions

Width22.61 mm
Height107.74 mm
Depth113.6 mm

Material specifications

Color (Housing)yellow (RAL 1018)
Housing MaterialPolyamide PA non-reinforced

Safety data

Stop category0

Safety data: EN ISO 13849

Performance level (PL)e (2-channel wiring)
Performance level (PL)d (1-channel wiring)

Safety data: IEC 61508 - High-demand for 2-channel wiring

Safety Integrity Level (SIL)3

Safety data: IEC 61508 - High-demand for 1-channel wiring

Safety Integrity Level (SIL)2

Safety data: EN IEC 62061

Safety Integrity Level (SIL)3 (2-channel wiring)
Safety Integrity Level (SIL)2 (1-channel wiring)

Ambient conditions

Degree of ProtectionIP20
Min. degree of protection of inst. locationIP54
Ambient Temperature (Operation)-10 °C ... 55 °C (observe derating)
Ambient temperature (storage/transport)-20 °C ... 85 °C
Maximum altitude≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport)95 % (non-condensing)
Max. permissible relative humidity (operation)95 % (non-condensing)
Shock10g for Δt = 16 ms (continuous shock, 1000 shocks in each space direction)
Vibration (Operation)10 Hz ... 150 Hz, 2g

CE

IdentificationCE-compliant

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsObserve derating
Mounting Positionvertical or horizontal
Accessories

Why Proax for Phoenix Contact 1104975?

Proax is an authorized distributor of Phoenix Contact 1104975 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability