FL SWITCH 2306-2SFP - Industrial Ethernet Switch

Managed Switch 2000, 6 RJ45 ports 10/100/1000 Mbps, 2 SFP ports 100/1000 Mbps, PROFINET Conformance-Class B, Extended temperature range

  • MRP (client and manager)
  • VLANs
  • DHCP client, DHCP server (pool-based and port-based), DHCP option 82
  • RSTP
  • Ambient temperature -40 °C ... 70 °C
  • Slim design
  • Configuration memory
  • Web-based management, SNMP
  • Easy and fast startup and commissioning with the FL NETWORK MANAGER software
  • Suitable for PROFINET and EtherNet/IP™ networks
Technical Specifications

Dimensions

Width45 mm
Height130 mm
Depth119 mm

Notes

GeneralSupport by phone or on-site (fee is charged)

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area

Material specifications

Housing MaterialPolycarbonate fiber reinforced

Mounting

Mounting TypeDIN rail mounting

Ethernet (RJ45)

Connection MethodRJ45
Note on the connection methodAuto negotiation and autocrossing
Transmission Speed10/100/1000 Mbps
Transmission physicsCopper
Transmission length100 m (per segment)
Signal LEDsData receive, link status
No. of channels6 (RJ45 ports)

Ethernet (SFP)

Number of interfaces2
Connection MethodSFP
Transmission Speed100/1000 Mbps (full duplex)
Transmission physicsDepending on the SFP module
Transmission lengthup to 80 km (Depending on the fiber/SFP module used)
Signal LEDsData receive, link status
No. of channels2 (SFP ports)

Digital:

Output nameAlarm output

Product properties

Product familyManaged Switch 2000
TypeBook type
MTTF491.44 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
MTTF212.99 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
MTTF24.97 Years (SN 29500 standard, temperature 70°C, operating cycle 100%)
Special PropertiesExtended temperature range
Signal delay≥ 1.9 µs (Store-and-Forward mode, 10/100/1000 Mbps, depending on the frame size)

Insulation characteristics

Protection classIII (VDE 0106)
Degree of pollution2

Switch functions

Diagnostic functionsRMON History
Diagnostic functionsLLDP (Link Layer Discovery Protocol)
Diagnostic functionsSNMP-Traps
Diagnostic functionsN:1-Portmirroring
Diagnostic functionsACD (Address Conflict Detection)
Diagnostic functionsSysLog
Diagnostic functionsCRC-Surveillance
Basic FunctionsStore-and-forward switch, complies with IEEE 802.3
Signal contact control voltagetyp. 24 V DC
PROFINET conformance classConformance-Class B
PROFINET device functionPROFINET device
PROFINET device functionFast Startup
Filter functionsQuality of Service (8 priority classes)
Filter functionsClass of Service
Filter functionsDiffServ/DSCP
Filter functionsPort-Priorisierung
Filter functionsVLAN (up to 32 VLANs)
Filter functionsIGMP Snooping/Querier (v1/v2)
Filter functionsAuto-Query-Port
Filter functionsExtended Multicast Filtering
IP parameterizationDHCP-Client
IP parameterizationDHCP Option 82 (Relay Agent)
IP parameterizationDHCP server (pool-based, port-based)
IP parameterizationBootP
IP parameterizationDCP (Discovery and Configuration Protocol)
MAC address table8k
ManagementWeb-based management (HTTP/HTTPS)
ManagementRole-based user management (LDAP, RADIUS)
ManagementSNMPv1/v2/v3
ManagementCommand Line Interface (Telnet, SSH)
RedundancyMRP (Media Redundancy Protocol)
RedundancyRSTP (Rapid Spanning Tree Protocol)
RedundancyFRD (Fast Ring Detection)
RedundancyLarge Tree Support
RedundancyLACP (Link Aggregation Control Protocol)
RedundancyPROFINET S2 system redundancy
Status and diagnostic indicatorsLEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (Link/Activity and Speed)
Additional functionsJumbo frames (max. 9,600 bytes)
Additional functionsTransmission of MMS and GOOSE (IEC 61850-8-1)
Additional functionsTransmission of Modbus/TCP
Time synchronizationSNTP (Simple Network Time Protocol)

Security functions

Port securityMAC-based, RADIUS (IEEE 802.1X), MAC Authentication Bypass
Basic FunctionsStore-and-forward switch, complies with IEEE 802.3

Electrical properties

Local diagnosticsUS1/2 Supply voltage US1, US2 Green LED
Local diagnosticsFAIL Div. LED red
Local diagnosticsLINK Link status Green LED
Maximum power dissipation for nominal condition9 W (US = Min, Tamb = Max, DOI = Max)
Test voltage500 V DC
Test sectionfor one minute 500 V DC
Transmission mediumCopper
Transmission mediumFO

Supply

Supply voltage (DC)24 V DC (redundant)
Supply Voltage Range12 V DC ... 57 V DC
Power supply connectionvia COMBICON, max. conductor cross section 1.5 mm²
Residual ripple3.6 VPP (within the permitted voltage range)
Max. current consumption1.5 A (US = Min, Tamb = Max, DOI = Max)
Typical current consumption280 mA (at US = 24 V DC and 25 °C ambient temperature)
Current consumption280 mA

Function

Signal contact control voltagetyp. 24 V DC

Connection data

Connection MethodPush-in spring connection
Note on the connection methodUse only copper connecting cables providing the permitted temperature range (-40 °C ... 75 °C).
Conductor cross section, rigid0.25 mm² ... 1.5 mm²
Conductor cross section, flexible0.25 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length9 mm

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)10 % ... 95 % (non-condensing)
Shock (operation)30g (EN 60068-2-27)
Vibration (Operation)in acc. with IEC 60068-2-6: 5g, 150 Hz
Air pressure (operation)80 kPa ... 110 kPa up to 2000 m above mean sea level (Without derating)
Air pressure (storage/transport)79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating)

Standards and Regulations

Free from substances that could impair the application of coatingYes

Approvals

Shipbuilding approvalTested in accordance with IEC 60945 and IACS E10

ATEX

Identification II 3 G Ex ec IIC T4 Gc
CertificateDEMKO 16 ATEX 1709X

IECEx

IdentificationEx ec IIC T4 Gc
CertificateIECEx ULD 16.0018 X
References to standardsIEC 60079-0
References to standardsIEC 60079-7

UL, USA/Canada

IdentificationcULus

UL Ex, USA / Canada

IdentificationClass I, Division 2, Groups A, B, C, and D, T4
IdentificationClass I, Zone 2, AEx ec IIC T4
IdentificationEx ec IIC T4 Gc X
CertificateE366272
NoteUL 60079-0 Ed. 6 / UL 60079-7 Ed. 5, CSA 22.2 No. 60079-0 Ed. 3 / CSA C22.2 No. 60079-7 Ed. 2

EAC Ex

Identification2Ex e IIC T4 Gc X
CertificateRU C-DE.HB49.B.00118/21

The following continue to apply for EAC Ex:

IdentificationПри монтаже использовать походящий допущенный корпус со степенью защиты не ниже IP66.
IdentificationНа корпусе/шкафу управления должна быть размещена предупреждающаяя надпись, запрещающая открывать корпус или шкаф во взрывоопасной зоне.
IdentificationЭксплуатация устройства допускается только при условии, что все оптические порты заняты подключенными устройствами или закрыты прилагаемыми заглушками.

CCC / China-Ex

IdentificationEx ec IIC T4 Gc
Certificate2022122310115629

Corrosive gas test

IdentificationISA S71.04.2013 G3 Harsh Group A

UKCA Ex (UKEX)

Identification II 3 G Ex ec IIC T4 Gc
CertificatePxCIMA22UKEX2702910X

DNV GL data

TemperatureB
HumidityB
VibrationA
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Conformance with EMC directivesEN 61000-6-2 EN 61000-4-2 (ESD) Criterion B
Conformance with EMC directivesEN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion A
Conformance with EMC directivesEN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A
Conformance with EMC directivesEN 61000-6-2 EN 61000-4-5 (surge) Criterion B
Conformance with EMC directivesEN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A
Conformance with EMC directivesEN 61000-6-2 EN 61000-6-4 (interference) Class A
Conformance with EMC directivesEN 61000-6-2 EN 61000-6-4 (conducted interference) Class A
Noise immunityEN 61000-6-2
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Noise emissionEN 61000-6-4

Functionality

Basic FunctionsStore-and-forward switch, complies with IEEE 802.3

Signaling

Status displayLEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (Link/Activity and Speed)
Accessories

Why Proax for Phoenix Contact 2702970?

Proax is an authorized distributor of Phoenix Contact 2702970 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability