It is possible for a return unit on a PF3W Digital Flow Sensor Manifold to reach its end of life. This may be due to some accident such as excessive external force, contamination, or electrical malfunction. If this happens, it is possible to replace an individual return unit for one lline without having to replace the entire manifold. The return unit may consist of a flow sensor block with or without a flow adjustment or stop valve, a temperature sensor, or a combination. Kits also include mounting screws and an O-ring seal.
Flow ranges (L/min): 0.5-4, 2-16, 5-40
Port sizes (Rc, NPT, G): 3/8, 1/2, 3/4 (flow range dependent)
Temperature rating: 0-90°C
Output options: IO-Link, PNP/NPN, 1-5V, 4-20mA
Accuracy: ±3% F.S. (display, analog out); ±5% F.S. (temperature sensor)
Why Proax for SMC PF3W, Return Unit Replacement for Manifold?
Proax is the Elite distributor of SMC PF3W, Return Unit Replacement for Manifold. We are SMC's largest distributor in Canada. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right etech as quickly as possible for your project. We're always here to help!