A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 20-60 V, DC
Technical Specifications

Dimensions

Product Net Width102 mm
Product Net Depth / Length123.5 mm
Product Net Height148 mm
Product Net Weight1.9 kg
Dimension Diagram53540923-8

Technical

Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Number of Poles3P
Rated Operational VoltageMain Circuit 1000 V
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 160 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 160 A
Rated Operational Current AC-1 (Ie)(690 V) 55 °C 145 A
Rated Operational Current AC-1 (Ie)(690 V) 70 °C 130 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 110 A
Rated Operational Current AC-3 (Ie)(440 V) 55 °C 100 A
Rated Operational Current AC-3 (Ie)(500 V) 55 °C 100 A
Rated Operational Current AC-3 (Ie)(690 V) 55 °C 82 A
Rated Operational Current AC-3 (Ie)(1000 V) 55 °C 30 A
Rated Operational Current AC-3 (Ie)(380 / 400 V) 55 °C 110 A
Rated Operational Current AC-3 (Ie)(220 / 230 / 240 V) 55 °C 110
Rated Operational Current DC-1 (Ie)(110 V) 2 Poles in Series, 40 °C 160 A
Rated Operational Current DC-1 (Ie)(220 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 40 °C 160 A
Rated Operational Current DC-3 (Ie)(220 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 40 °C 160 A
Rated Operational Current DC-5 (Ie)(220 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Power AC-3 (Pe)(415 V) 59 kW
Rated Operational Power AC-3 (Pe)(440 V) 59 kW
Rated Operational Power AC-3 (Pe)(500 V) 59 kW
Rated Operational Power AC-3 (Pe)(690 V) 75 kW
Rated Operational Power AC-3 (Pe)(1000 V) 40 kW
Rated Operational Power AC-3 (Pe)(380 / 400 V) 55 kW
Rated Operational Power AC-3 (Pe)(220 / 230 / 240 V) 30 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Making Capacity AC-310 x Ie AC-3
Short-Circuit Protective DevicesgG Type Fuses 160 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Insulation Voltage (Ui)acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
Maximum Electrical Switching Frequency(AC-2 / AC-4) 150 cycles per hour
Maximum Electrical Switching Frequency(AC-3) 300 cycles per hour
Mechanical Durability10 million
Maximum Mechanical Switching Frequency300 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)DC Operation 20 ... 60 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 7 V·A
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 60 Hz 7 V·A
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage DC 2 W
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage 60 Hz 350 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage DC 400 W
Power Lossat Rated Operating Conditions per Pole 3.5 W
Operate TimeBetween Coil De-energization and NC Contact Closing 60 ... 130 ms
Operate TimeBetween Coil De-energization and NO Contact Opening 55 ... 125 ms
Operate TimeBetween Coil Energization and NC Contact Opening 27 ... 77 ms
Operate TimeBetween Coil Energization and NO Contact Closing 30 ... 80 ms
Connecting Capacity Main CircuitBar 30 mm²
Connecting Capacity Main CircuitFlexible with Cable End 2 x 6 ... 35 mm²
Connecting Capacity Main CircuitRigid 2 x 6 ... 65 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 2x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible 1x0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitSolid 2 x 1 ... 4 mm²
Connecting Capacity Auxiliary CircuitStranded 2 x 1 .... 4 mm²
Connecting CapacityBar 30 mm²
Connecting CapacityFlexible with Cable End 1 x 10 ... 70 mm²
Connecting CapacityRigid 2 x 6 ... 65 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting Terminals (delivered in open position) Main PolesM8 hexagon socket screw with single connector
Tightening torqueMain Circuit 8 N·m
Terminal TypeCable Clamp
Product NameBlock Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(600 V AC) 140 A
Horsepower Rating UL/CSA(200 V AC) Three Phase 30 hp
Horsepower Rating UL/CSA(208 V AC) Three Phase 30 hp
Horsepower Rating UL/CSA(220 ... 240 V AC) Three Phase 40 hp
Horsepower Rating UL/CSA(440 ... 480 V AC) Three Phase 75 hp
Horsepower Rating UL/CSA(550 ... 600 V AC) Three Phase 100 hp
Full Load Amps Motor Use(440 ... 480 V AC) Three Phase 96 A
Full Load Amps Motor Use(550 ... 600 V AC) Three Phase 99 A

Why Proax for ABB AF110-30-11-72?

Proax is an authorized distributor of ABB AF110-30-11-72 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate NamesAF110301172
Pack Size1
Recommended

Price N/A

Not in stock

Request lead time or order—we'll ensure quick delivery

ABB Availability