By ABB
Documents
AF 4-pole Contactors
Secure uptime and optimize stock management with AF technology, offering superior performance and energy savings (up to 80% reduction). The electronically controlled coil ensures stability against voltage drops and sags, while ABB’s global product range simplifies logistics.
Key Features:
Up to 1000 A, 690 V AC-1 and 540 A, 600 V general use
Wide voltage range: 24 V - 500 V AC / 20 V - 500 V DC
Built-in surge suppression
Snap-to-connect accessories for easy installation
Mirror and mechanically linked contacts for safety
Dimensions
Product Net Width | 45 mm |
Product Net Depth / Length | 77 mm |
Product Net Height | 86 mm |
Product Net Weight | 0.31 kg |
Technical
Number of Main Contacts NO | 4 |
Number of Main Contacts NC | 0 |
Number of Auxiliary Contacts NO | 0 |
Number of Auxiliary Contacts NC | 0 |
Standards | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1 |
Rated Operational Voltage | Main Circuit 690 V |
Rated Frequency (f) | Control Circuit 50 / 60 Hz |
Rated Frequency (f) | Main Circuit 50 / 60 Hz |
Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 35 A |
Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 25 A |
Rated Operational Current AC-1 (Ie) | (690 V) 60 °C 25 A |
Rated Operational Current AC-1 (Ie) | (690 V) 70 °C 22 A |
Rated Operational Current AC-3 (Ie) | (415 V) 60 °C 9 A |
Rated Operational Current AC-3 (Ie) | (440 V) 60 °C 9 A |
Rated Operational Current AC-3 (Ie) | (500 V) 60 °C 9.5 A |
Rated Operational Current AC-3 (Ie) | (690 V) 60 °C 7 A |
Rated Operational Current AC-3 (Ie) | (380 / 400 V) 60 °C 9 A |
Rated Operational Current AC-3 (Ie) | (220 / 230 / 240 V) 60 °C 9 A |
Rated Operational Power AC-3 (Pe) | (400 V) 4 kW |
Rated Operational Power AC-3 (Pe) | (415 V) 4 kW |
Rated Operational Power AC-3 (Pe) | (440 V) 4 kW |
Rated Operational Power AC-3 (Pe) | (500 V) 5.5 kW |
Rated Operational Power AC-3 (Pe) | (690 V) 5.5 kW |
Rated Operational Power AC-3 (Pe) | (380 / 400 V) 4 kW |
Rated Operational Power AC-3 (Pe) | (220 / 230 / 240 V) 2.2 kW |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A |
Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A |
Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A |
Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour |
Rated Operational Current DC-1 (Ie) | (110 V) 1-Pole, 40 °C 10 A |
Rated Operational Current DC-1 (Ie) | (110 V) 1-Pole, 60 °C 10 A |
Rated Operational Current DC-1 (Ie) | (110 V) 1-Pole, 70 °C 10 A |
Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 40 °C 25 A |
Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 60 °C 25 A |
Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 70 °C 22 A |
Rated Operational Current DC-1 (Ie) | (110 V) 3 Poles in Series, 40 °C 25 A |
Rated Operational Current DC-1 (Ie) | (110 V) 3 Poles in Series, 60 °C 25 A |
Rated Operational Current DC-1 (Ie) | (110 V) 3 Poles in Series, 70 °C 22 A |
Rated Operational Current DC-1 (Ie) | (110 V) 4 Poles in Series, 40 °C 25 A |
Rated Operational Current DC-1 (Ie) | (110 V) 4 Poles in Series, 60 °C 25 A |
Rated Operational Current DC-1 (Ie) | (110 V) 4 Poles in Series, 70 °C 22 A |
Rated Operational Current DC-1 (Ie) | (220 V) 2 Poles in Series, 40 °C 10 A |
Rated Operational Current DC-1 (Ie) | (220 V) 2 Poles in Series, 60 °C 10 A |
Rated Operational Current DC-1 (Ie) | (220 V) 2 Poles in Series, 70 °C 10 A |
Rated Operational Current DC-1 (Ie) | (220 V) 3 Poles in Series, 40 °C 25 A |
Rated Operational Current DC-1 (Ie) | (220 V) 3 Poles in Series, 60 °C 25 A |
Rated Operational Current DC-1 (Ie) | (220 V) 3 Poles in Series, 70 °C 22 A |
Rated Operational Current DC-1 (Ie) | (220 V) 4 Poles in Series, 40 °C 25 A |
Rated Operational Current DC-1 (Ie) | (220 V) 4 Poles in Series, 60 °C 25 A |
Rated Operational Current DC-1 (Ie) | (220 V) 4 Poles in Series, 70 °C 22 A |
Rated Operational Current DC-1 (Ie) | (440 V) 4 Poles in Series, 40 °C 10 A |
Rated Operational Current DC-1 (Ie) | (440 V) 4 Poles in Series, 60 °C 10 A |
Rated Operational Current DC-1 (Ie) | (440 V) 4 Poles in Series, 70 °C 10 A |
Rated Operational Current DC-1 (Ie) | (72 V) 1-Pole, 40 °C 25 A |
Rated Operational Current DC-1 (Ie) | (72 V) 1-Pole, 60 °C 25 A |
Rated Operational Current DC-1 (Ie) | (72 V) 1-Pole, 70 °C 22 A |
Rated Operational Current DC-1 (Ie) | (72 V) 2 Poles in Series, 40 °C 25 A |
Rated Operational Current DC-1 (Ie) | (72 V) 2 Poles in Series, 60 °C 25 A |
Rated Operational Current DC-1 (Ie) | (72 V) 2 Poles in Series, 70 °C 22 A |
Rated Operational Current DC-1 (Ie) | (72 V) 3 Poles in Series, 40 °C 25 A |
Rated Operational Current DC-1 (Ie) | (72 V) 3 Poles in Series, 60 °C 25 A |
Rated Operational Current DC-1 (Ie) | (72 V) 3 Poles in Series, 70 °C 22 A |
Rated Operational Current DC-1 (Ie) | (72 V) 4 Poles in Series, 40 °C 25 A |
Rated Operational Current DC-1 (Ie) | (72 V) 4 Poles in Series, 60 °C 25 A |
Rated Operational Current DC-1 (Ie) | (72 V) 4 Poles in Series, 70 °C 22 A |
Rated Operational Current DC-3 (Ie) | (110 V) 1-Pole, 40 °C 6 A |
Rated Operational Current DC-3 (Ie) | (110 V) 1-Pole, 60 °C 6 A |
Rated Operational Current DC-3 (Ie) | (110 V) 1-Pole, 70 °C 6 A |
Rated Operational Current DC-3 (Ie) | (110 V) 2 Poles in Series, 40 °C 25 A |
Rated Operational Current DC-3 (Ie) | (110 V) 2 Poles in Series, 60 °C 25 A |
Rated Operational Current DC-3 (Ie) | (110 V) 2 Poles in Series, 70 °C 22 A |
Rated Operational Current DC-3 (Ie) | (110 V) 3 Poles in Series, 40 °C 25 A |
Rated Operational Current DC-3 (Ie) | (110 V) 3 Poles in Series, 60 °C 25 A |
Rated Operational Current DC-3 (Ie) | (110 V) 3 Poles in Series, 70 °C 22 A |
Rated Operational Current DC-3 (Ie) | (110 V) 4 Poles in Series, 40 °C 25 A |
Rated Operational Current DC-3 (Ie) | (110 V) 4 Poles in Series, 60 °C 25 A |
Rated Operational Current DC-3 (Ie) | (110 V) 4 Poles in Series, 70 °C 22 A |
Rated Operational Current DC-3 (Ie) | (220 V) 2 Poles in Series, 40 °C 6 A |
Rated Operational Current DC-3 (Ie) | (220 V) 2 Poles in Series, 60 °C 6 A |
Rated Operational Current DC-3 (Ie) | (220 V) 2 Poles in Series, 70 °C 6 A |
Rated Operational Current DC-3 (Ie) | (220 V) 3 Poles in Series, 40 °C 25 A |
Rated Operational Current DC-3 (Ie) | (220 V) 3 Poles in Series, 60 °C 25 A |
Rated Operational Current DC-3 (Ie) | (220 V) 3 Poles in Series, 70 °C 22 A |
Rated Operational Current DC-3 (Ie) | (220 V) 4 Poles in Series, 40 °C 25 A |
Rated Operational Current DC-3 (Ie) | (220 V) 4 Poles in Series, 60 °C 25 A |
Rated Operational Current DC-3 (Ie) | (220 V) 4 Poles in Series, 70 °C 22 A |
Rated Operational Current DC-3 (Ie) | (440 V) 4 Poles in Series, 40 °C 6 A |
Rated Operational Current DC-3 (Ie) | (440 V) 4 Poles in Series, 60 °C 6 A |
Rated Operational Current DC-3 (Ie) | (440 V) 4 Poles in Series, 70 °C 6 A |
Rated Operational Current DC-3 (Ie) | (72 V) 1-Pole, 40 °C 25 A |
Rated Operational Current DC-3 (Ie) | (72 V) 1-Pole, 60 °C 25 A |
Rated Operational Current DC-3 (Ie) | (72 V) 1-Pole, 70 °C 22 A |
Rated Operational Current DC-3 (Ie) | (72 V) 2 Poles in Series, 40 °C 25 A |
Rated Operational Current DC-3 (Ie) | (72 V) 2 Poles in Series, 60 °C 25 A |
Rated Operational Current DC-3 (Ie) | (72 V) 2 Poles in Series, 70 °C 22 A |
Rated Operational Current DC-3 (Ie) | (72 V) 3 Poles in Series, 40 °C 25 A |
Rated Operational Current DC-3 (Ie) | (72 V) 3 Poles in Series, 60 °C 25 A |
Rated Operational Current DC-3 (Ie) | (72 V) 3 Poles in Series, 70 °C 22 A |
Rated Operational Current DC-3 (Ie) | (72 V) 4 Poles in Series, 40 °C 25 A |
Rated Operational Current DC-3 (Ie) | (72 V) 4 Poles in Series, 60 °C 25 A |
Rated Operational Current DC-3 (Ie) | (72 V) 4 Poles in Series, 70 °C 22 A |
Rated Operational Current DC-5 (Ie) | (110 V) 1-Pole, 40 °C 4 A |
Rated Operational Current DC-5 (Ie) | (110 V) 1-Pole, 60 °C 4 A |
Rated Operational Current DC-5 (Ie) | (110 V) 1-Pole, 70 °C 4 A |
Rated Operational Current DC-5 (Ie) | (110 V) 2 Poles in Series, 40 °C 10 A |
Rated Operational Current DC-5 (Ie) | (110 V) 2 Poles in Series, 60 °C 10 A |
Rated Operational Current DC-5 (Ie) | (110 V) 2 Poles in Series, 70 °C 10 A |
Rated Operational Current DC-5 (Ie) | (110 V) 3 Poles in Series, 40 °C 25 A |
Rated Operational Current DC-5 (Ie) | (110 V) 3 Poles in Series, 60 °C 25 A |
Rated Operational Current DC-5 (Ie) | (110 V) 3 Poles in Series, 70 °C 22 A |
Rated Operational Current DC-5 (Ie) | (110 V) 4 Poles in Series, 40 °C 25 A |
Rated Operational Current DC-5 (Ie) | (110 V) 4 Poles in Series, 60 °C 25 A |
Rated Operational Current DC-5 (Ie) | (110 V) 4 Poles in Series, 70 °C 22 A |
Rated Operational Current DC-5 (Ie) | (220 V) 2 Poles in Series, 40 °C 4 A |
Rated Operational Current DC-5 (Ie) | (220 V) 2 Poles in Series, 60 °C 4 A |
Rated Operational Current DC-5 (Ie) | (220 V) 2 Poles in Series, 70 °C 4 A |
Rated Operational Current DC-5 (Ie) | (220 V) 3 Poles in Series, 40 °C 9 A |
Rated Operational Current DC-5 (Ie) | (220 V) 3 Poles in Series, 60 °C 9 A |
Rated Operational Current DC-5 (Ie) | (220 V) 3 Poles in Series, 70 °C 9 A |
Rated Operational Current DC-5 (Ie) | (220 V) 4 Poles in Series, 40 °C 10 A |
Rated Operational Current DC-5 (Ie) | (220 V) 4 Poles in Series, 60 °C 10 A |
Rated Operational Current DC-5 (Ie) | (220 V) 4 Poles in Series, 70 °C 10 A |
Rated Operational Current DC-5 (Ie) | (440 V) 4 Poles in Series, 40 °C 4 A |
Rated Operational Current DC-5 (Ie) | (440 V) 4 Poles in Series, 60 °C 4 A |
Rated Operational Current DC-5 (Ie) | (440 V) 4 Poles in Series, 70 °C 4 A |
Rated Operational Current DC-5 (Ie) | (72 V) 1-Pole, 40 °C 9 A |
Rated Operational Current DC-5 (Ie) | (72 V) 1-Pole, 60 °C 9 A |
Rated Operational Current DC-5 (Ie) | (72 V) 1-Pole, 70 °C 9 A |
Rated Operational Current DC-5 (Ie) | (72 V) 2 Poles in Series, 40 °C 25 A |
Rated Operational Current DC-5 (Ie) | (72 V) 2 Poles in Series, 60 °C 25 A |
Rated Operational Current DC-5 (Ie) | (72 V) 2 Poles in Series, 70 °C 22 A |
Rated Operational Current DC-5 (Ie) | (72 V) 3 Poles in Series, 40 °C 25 A |
Rated Operational Current DC-5 (Ie) | (72 V) 3 Poles in Series, 60 °C 25 A |
Rated Operational Current DC-5 (Ie) | (72 V) 3 Poles in Series, 70 °C 22 A |
Rated Operational Current DC-5 (Ie) | (72 V) 4 Poles in Series, 40 °C 25 A |
Rated Operational Current DC-5 (Ie) | (72 V) 4 Poles in Series, 60 °C 25 A |
Rated Operational Current DC-5 (Ie) | (72 V) 4 Poles in Series, 70 °C 22 A |
Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 690 V |
Rated Insulation Voltage (Ui) | acc. to UL/CSA 600 V |
Rated Impulse Withstand Voltage (Uimp) | 6 kV |
Maximum Mechanical Switching Frequency | 3600 cycles per hour |
Rated Control Circuit Voltage (Uc) | 50 Hz 100 ... 250 V |
Rated Control Circuit Voltage (Uc) | 60 Hz 100 ... 250 V |
Rated Control Circuit Voltage (Uc) | DC Operation 100 ... 250 V |
Operate Time | Between Coil De-energization and NC Contact Closing 13 ... 98 ms |
Operate Time | Between Coil De-energization and NO Contact Opening 11 ... 95 ms |
Operate Time | Between Coil Energization and NC Contact Opening 38 ... 90 ms |
Operate Time | Between Coil Energization and NO Contact Closing 40 ... 95 ms |
Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
Mounting on DIN Rail | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
Mounting by Screws (not supplied) | 2 x M4 screws placed diagonally |
Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 6 mm² |
Connecting Capacity Main Circuit | Flexible with Insulated Ferrule 1x 0.75 ... 4 mm² |
Connecting Capacity Main Circuit | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² |
Connecting Capacity Main Circuit | Rigid Solid 1/2x 1 ... 4 mm² |
Connecting Capacity Main Circuit | Rigid Stranded 1/2x 1 ... 6 mm² |
Connecting Capacity Auxiliary Circuit | Rigid Solid 1/2x 1 ... 2.5 mm² |
Connecting Capacity Auxiliary Circuit | Rigid Stranded 1/2x 1 ... 2.5 mm² |
Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
Connecting Capacity Control Circuit | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² |
Connecting Capacity Control Circuit | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² |
Connecting Capacity Control Circuit | Rigid Solid 1/2x 1 ... 2.5 mm² |
Connecting Capacity Control Circuit | Rigid Stranded 1/2x 1 ... 2.5 mm² |
Wire Stripping Length | Control Circuit 10 mm |
Wire Stripping Length | Main Circuit 10 mm |
Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 |
Terminal Type | Screw Terminals |
Technical UL/CSA
Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
General Use Rating UL/CSA | (600 V AC) 25 A |
Connecting Capacity Main Circuit UL/CSA | Rigid Solid 1/2x 16-10 AWG |
Connecting Capacity Main Circuit UL/CSA | Rigid Stranded 1/2x 16-10 AWG |
Connecting Capacity Auxiliary Circuit UL/CSA | Rigid Solid 1/2x 18-14 AWG |
Connecting Capacity Auxiliary Circuit UL/CSA | Rigid Stranded 1/2x 18-14 AWG |
Connecting Capacity Control Circuit UL/CSA | Rigid Solid 1/2x 18-14 AWG |
Connecting Capacity Control Circuit UL/CSA | Rigid Stranded 1/2x 18-14 AWG |
Tightening Torque UL/CSA | Control Circuit 11 in·lb |
Tightening Torque UL/CSA | Main Circuit 13 in·lb |
Why Proax for ABB AF09Z-40-00-23?
Proax is an authorized distributor of ABB AF09Z-40-00-23 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Alternate Names | AF09Z400023 |
Pack Size | 1 |