Proax

Currency
0 Items
proax logo
Cart
ABBOfficial Distributor

By ABB

SKU
The AF09Z-30-10-23 is a 3 pole - 690 V IEC or 600 UL contactor with 1 built-in auxiliary contact and screw terminals, controlling motors up to 4 kW / 400 V AC (AC-3) or 5 hp / 480 V UL and switching power circuits up to 25 A (AC-1) or 25 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Technical Specifications

Dimensions

Product Net Width45 mm
Product Net Depth / Length77 mm
Product Net Height86 mm
Product Net Weight0.31 kg

Technical

Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC0
StandardsIEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-16, UL 60947-4-1, CSA C22.2 No. 60947-4-1
Rated Operational VoltageAuxiliary Circuit 690 V, Main Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors q = 40 °C 35 A, acc. to IEC 60947-5-1, q = 40 °C 16 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 25 A, (690 V) 60 °C 25 A, (690 V) 70 °C 22 A
Rated Operational Current AC-3 (Ie)(415 V) 60 °C 9 A, (440 V) 60 °C 9 A, (500 V) 60 °C 9.5 A, (690 V) 60 °C 7 A, (380 / 400 V) 60 °C 9 A, (220 / 230 / 240 V) 60 °C 9 A
Rated Operational Current AC-3e (Ie)(415 V) 60 °C 9 A, (440 V) 60 °C 9 A, (500 V) 60 °C 9.5 A, (690 V) 60 °C 7 A, (380 / 400 V) 60 °C 9 A, (220 / 230 / 240 V) 60 °C 9 A
Rated Operational Power AC-3 (Pe)(400 V) 4 kW, (415 V) 4 kW, (440 V) 4 kW, (500 V) 5.5 kW, (690 V) 5.5 kW, (380 / 400 V) 4 kW, (220 / 230 / 240 V) 2.2 kW
Rated Operational Power AC-3e (Pe)(415 V) 4 kW, (440 V) 4 kW, (500 V) 5.5 kW, (690 V) 5.5 kW, (380 / 400 V) 4 kW, (220 / 230 / 240 V) 2.2 kW
Rated Operational Current AC-15 (Ie)(500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (400 / 440 V) 3 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A, for 0.1 s 140 A, for 1 s 100 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour, (AC-15) 1200 cycles per hour, (AC-2 / AC-4) 300 cycles per hour, (AC-3) 1200 cycles per hour, (DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie)(24 V) 6 A / 144 W, (48 V) 2.8 A / 134 W, (72 V) 1 A / 72 W, (110 V) 0.55 A / 60 W, (125 V) 0.55 A / 69 W, (220 V) 0.27 A / 60 W, (250 V) 0.27 A / 68 W, (400 V) 0.15 A / 60 W, (500 V) 0.13 A / 65 W, (600 V) 0.1 A / 60 W
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V, acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)6 kV
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 100 ... 250 V, 60 Hz 100 ... 250 V, DC Operation 100 ... 250 V
Operate TimeBetween Coil De-energization and NC Contact Closing 13 ... 98 ms, Between Coil De-energization and NO Contact Opening 11 ... 95 ms, Between Coil Energization and NC Contact Opening 38 ... 90 ms, Between Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715, TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)2 x M4 screws placed diagonally
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 6 mm², Flexible with Insulated Ferrule 1x 0.75 ... 4 mm², Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm², Rigid 1/2x 1 ... 6 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Rigid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm², Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 10 mm, Control Circuit 10 mm, Main Circuit 10 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Terminal TypeScrew Terminals

Technical UL/CSA

NEMA Size00
Continuous Current Rating NEMA9 A
Horsepower Rating NEMA(115 V AC) Single Phase 1/3 Hp, (200 V AC) Three Phase 1-1/2 Hp, (230 V AC) Single Phase 1 Hp, (230 V AC) Three Phase 1-1/2 Hp, (460 V AC) Three Phase 2 Hp, (575 V AC) Three Phase 2 Hp
General Use Rating UL/CSA(600 V AC) 25 A
Horsepower Rating UL/CSA(120 V AC) Single Phase 3/4 hp, (200 ... 208 V AC) Three Phase 2 hp, (220 ... 240 V AC) Three Phase 2 hp, (240 V AC) Single Phase 1-1/2 hp, (440 ... 480 V AC) Three Phase 5 hp, (550 ... 600 V AC) Three Phase 7-1/2 hp
Tightening Torque UL/CSAAuxiliary Circuit 11 in·lb, Control Circuit 11 in·lb, Main Circuit 13 in·lb

Environmental

Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C, Close to Contactor without Thermal O/L Relay -40 ... 70 °C, Close to Contactor for Storage -60 ... +80 °C
Climatic WithstandCategory B according to IEC 60947-1 Annex Q
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Resistance to Vibrations acc. to IEC 60068-2-65 ... 300 Hz 4 g closed position / 2 g open position
Resistance to Shock acc. to IEC 60068-2-27Closed, Shock Direction: B1 25 g, Open, Shock Direction: B1 5 g, Shock Direction: A 30 g, Shock Direction: B2 15 g, Shock Direction: C1 25 g, Shock Direction: C2 25 g
RoHS StatusFollowing EU Directive 2011/65/EU

Why Proax for ABB AF09Z-30-10-23?

Proax is an authorized distributor of ABB AF09Z-30-10-23 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesAF09Z301023
Pack Size1
Recommended

Available for order

ABB Availability