ABBOfficial Distributor

By ABB

SKU
MPN
1SFL431001R8011
Weight
2.041 kg
A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V.Operated with control voltage, versions from 24….690 AC, 50 and 60 Hz
Technical Specifications

Dimensions

Product Net Width102 mm
Product Net Depth / Length123.5 mm
Product Net Height148 mm
Product Net Weight1.8 kg

Technical

Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 145 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 145 A
Rated Operational Current AC-1 (Ie)(690 V) 55 °C 135 A
Rated Operational Current AC-1 (Ie)(690 V) 70 °C 115 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 96 A
Rated Operational Current AC-3 (Ie)(440 V) 55 °C 93 A
Rated Operational Current AC-3 (Ie)(500 V) 55 °C 80 A
Rated Operational Current AC-3 (Ie)(690 V) 55 °C 65 A
Rated Operational Current AC-3 (Ie)(1000 V) 55 °C 30 A
Rated Operational Current AC-3 (Ie)(380 / 400 V) 55 °C 96 A
Rated Operational Current AC-3 (Ie)(220 / 230 / 240 V) 55 °C 96
Rated Operational Power AC-3 (Pe)(415 V) 55 kW
Rated Operational Power AC-3 (Pe)(440 V) 55 kW
Rated Operational Power AC-3 (Pe)(500 V) 55 kW
Rated Operational Power AC-3 (Pe)(690 V) 55 kW
Rated Operational Power AC-3 (Pe)(1000 V) 40 kW
Rated Operational Power AC-3 (Pe)(380 / 400 V) 45 kW
Rated Operational Power AC-3 (Pe)(220 / 230 / 240 V) 25 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Making Capacity AC-310 x Ie AC-3
Short-Circuit Protective DevicesgG Type Fuses 160 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
Maximum Electrical Switching Frequency(AC-2 / AC-4) 150 cycles per hour
Maximum Electrical Switching Frequency(AC-3) 300 cycles per hour
Rated Operational Current DC-1 (Ie)(110 V) 2 Poles in Series, 40 °C 145 A
Rated Operational Current DC-1 (Ie)(220 V) 3 Poles in Series, 40 °C 145 A
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 40 °C 145 A
Rated Operational Current DC-3 (Ie)(220 V) 3 Poles in Series, 40 °C 145 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 40 °C 145 A
Rated Operational Current DC-5 (Ie)(220 V) 3 Poles in Series, 40 °C 145 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Insulation Voltage (Ui)acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
Mechanical Durability10 million
Maximum Mechanical Switching Frequency3600 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 220 ... 230 V
Rated Control Circuit Voltage (Uc)60 Hz 230 ... 240 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 22 V·A
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 60 Hz 26 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage 60 Hz 450 V·A
Operate TimeBetween Coil De-energization and NC Contact Closing 7 ... 15 ms
Operate TimeBetween Coil De-energization and NO Contact Opening 10 ... 18 ms
Operate TimeBetween Coil Energization and NC Contact Opening 7 ... 22 ms
Operate TimeBetween Coil Energization and NO Contact Closing 10 ... 25 ms
Connecting Capacity Main CircuitBar 30 mm²
Connecting Capacity Main CircuitFlexible with Cable End 2 x 6 ... 35 mm²
Connecting Capacity Main CircuitRigid 1 x 10 ... 95 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 2x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible 2x0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitSolid 2 x 1 ... 4 mm²
Connecting Capacity Auxiliary CircuitStranded 2 x 1 .... 4 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting Terminals (delivered in open position) Main PolesM8 hexagon socket screw with single connector
Terminal TypeCable Clamp

Technical UL/CSA

Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(600 V AC) 125 A
Horsepower Rating UL/CSA(200 V AC) Three Phase 30 hp
Horsepower Rating UL/CSA(208 V AC) Three Phase 30 hp
Horsepower Rating UL/CSA(220 ... 240 V AC) Three Phase 30 hp
Horsepower Rating UL/CSA(440 ... 480 V AC) Three Phase 60 hp
Horsepower Rating UL/CSA(550 ... 600 V AC) Three Phase 75 hp

Why Proax for ABB A95-30-11-80?

Proax is an authorized distributor of ABB A95-30-11-80 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesA95301180
Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

ABB Availability