Series PTPOWER

PTPOWER 50-F - High-current terminal block

High-current terminal block, nom. voltage: 1000 V, nominal current: 150 A, number of connections: 2, number of positions: 1, connection method: PowerTurn connection, 1 level, cross section: 10 mm2 - 70 mm2, mounting type: direct screw connection, color: gray

  • Quick and easy connection is now also possible for large conductors with the high-current terminal block
  • The compact design enables wiring in a confined space
  • In addition to using the existing test pick-off, pick-off terminal blocks can be connected, each of which can also accommodate two test cables
  • The Push-in connection terminal blocks are characterized by the system features of the CLIPLINE complete system and by easy and tool-free wiring of conductors with ferrules or solid conductors
Technical Specifications

Product properties

Number of Positions1
Pitch20 mm
Number of Connections2
Number of rows1
Potentials1

Insulation characteristics

Overvoltage categoryIII
Degree of pollution3

Electrical properties

Rated surge voltage8 kV
Maximum power dissipation for nominal condition4.73 W

Connection data

Number of connections per level2
Nominal cross section50 mm²
Rated cross section AWG2/0

1 level

Stripping length30 mm ... 32 mm
Internal cylindrical gageA10
Connection in acc. with standardIEC 60947-7-1
Conductor cross section rigid10 mm² ... 70 mm²
Cross section AWG6 ... 2/0 (converted acc. to IEC)
Conductor cross section flexible10 mm² ... 70 mm²
Conductor cross section, flexible [AWG]6 ... 2/0 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)10 mm² ... 50 mm²
Flexible conductor cross section (ferrule with plastic sleeve)10 mm² ... 50 mm²
Cross-section with insertion bridge, rigid10 mm² ... 50 mm²
Cross-section with insertion bridge, flexible10 mm² ... 50 mm²
Cross-section with insertion bridge, flexible, with ferrule without plastic sleeve10 mm² ... 50 mm²
Cross-section with insertion bridge, flexible, with ferrule with plastic sleeve10 mm² ... 50 mm²
Nominal Current150 A
Maximum Load Current150 A (with 50 mm² conductor cross section)
Nominal Voltage1000 V

1 level Connection cross sections directly pluggable

Conductor cross section rigid10 mm² ... 70 mm²
Conductor cross section, rigid [AWG]8 ... 2/0 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)10 mm² ... 50 mm²
Flexible conductor cross section (ferrule with plastic sleeve)10 mm² ... 50 mm²

Rated data (ATEX/IECEx)

Identification II 2 GD  Ex eb IIC Gb
Operating temperature range-60 °C ... 110 °C
Ex-certified accessories1206612 SZF 3-1,0X5,5
Ex-certified accessories1201662 E/AL-NS 35
List of bridges/ EB 2-20/PT / 3260067
List of bridges/ EB 3-20/PT / 3260068
Bridge data131 A / 50 mm²
Ex temperature increase40 K (147 A / 50 mm²)
Rated voltage1100 V
at bridging with insertion bridge1100 V
Rated Insulation Voltage1000 V
Output(Permanent)

Ex level General

Rated current134 A
Maximum Load Current134 A
Contact resistance0.16 mΩ

Ex connection data General

Ferrule length30  mm ... 32 mm
Stripping length30 mm
Nominal cross section50 mm²
Rated cross section AWG1/0
Connection capacity rigid10 mm² ... 70 mm²
Connection capacity AWG8 ... 2/0
Conductor cross section flexible, with ferrule without plastic sleeve min.16 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.50 mm²

Dimensions

Width20 mm
Height136.1 mm
Depth96 mm
Drill hole spacing123.4 mm
Hole diameter6.5 mm
Pitch20 mm

Material specifications

Colorgray
Flammability rating according to UL 94V0
Insulating material groupI
Insulating materialPA
Static insulating material application in cold-60 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))125 °C
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Calorimetric heat release NFPA 130 (ASTM E 1354)27,5 MJ/kg
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed

Surge voltage test

Test voltage setpoint9.8 kV
ResultTest passed

Temperature-rise test

Requirement temperature-rise testIncrease in temperature ≤ 45 K
ResultTest passed
Short-time withstand current 50 mm²6 kA
ResultTest passed

Power-frequency withstand voltage

ResultTest passed

Mechanical data

Open side panelNo

Technical data

Drill hole spacing123.4 mm

Mechanical strength

ResultTest passed

Attachment on the carrier

Test force setpoint10 N
ResultTest passed

Test for conductor damage and slackening

Rotation speed10 rpm
Revolutions135
Conductor cross section/weight10 mm² / 2 kg
Conductor cross section/weight50 mm² / 9.5 kg
Conductor cross section/weight70 mm²/10.4 kg
ResultTest passed

Aging

Temperature cycles192
ResultTest passed

Needle-flame test

Time of exposure30 s
ResultTest passed

Oscillation/broadband noise

SpecificationDIN EN 50155 (VDE 0115-200):2018-05
SpectrumService life test category 2, bogie-mounted
Frequencyf1 = 5 Hz to f2 = 250 Hz
ASD level6.12 (m/s²)²/Hz
Acceleration3.12g
Test duration per axis5 h
Test directionsX-, Y- and Z-axis
ResultTest passed

Shocks

SpecificationDIN EN 50155 (VDE 0115-200):2018-05
Pulse shapeHalf-sine
Acceleration30g
Shock duration18 ms
Number of shocks per direction3
Test directionsX-, Y- and Z-axis (pos. and neg.)
ResultTest passed

Ambient conditions

Ambient Temperature (Operation)-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
Ambient temperature (assembly)-5 °C ... 70 °C
Ambient temperature (actuation)-5 °C ... 70 °C
Permissible humidity (operation)20 % ... 90 %
Permissible humidity (storage/transport)30 % ... 70 %

Standards and Regulations

Connection in acc. with standardIEC 60947-7-1

Mounting

Mounting Typedirect screw connection
Accessories

Why Proax for Phoenix Contact 3260061?

Proax is an authorized distributor of Phoenix Contact 3260061 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size10
Recommended
Sold in quantities of 10

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability