Series PLC-BPT

PLC-BPT-120UC/21/SO46 - Relay base

6.2 mm PLC basic terminal block against interference currents/voltages on the control side with Push-in connection, without relay or solid-state relay, for mounting on DIN rail NS 35/7,5, with integrated RCZ filter, 1 changeover contact, input voltage 120 V AC

  • High relay release voltage
  • Resistant to interference currents
Technical Specifications

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area

Product properties

Product familyPLC-INTERFACE
ApplicationFilter to prevent interference
Operating mode100% operating factor
Compatible componentsMiniature relay, REL-MR-60DC/21AU, REL-MR-60DC/21; miniature optocoupler, OPT-60DC/48DC/100, OPT-60DC/24DC/2, OPT-60DC/230AC/1

Electrical properties

Protective circuitBridge rectifier; Bridge rectifier
Protective circuitRCZ filter; RCZ filter

Input data

Nominal input voltage UN120 V AC
Nominal input voltage UN110 V DC

Relay assembly

Nominal input voltage UN120 V AC
Nominal input voltage UN110 V DC
Input voltage range in reference to UN0.8 ... 1.4
Typical input current at UN7 mA (50 Hz)
Typical input current at UN8 mA (60 Hz)
Typical response time7 ms
Typical release time20 ms
Typical release voltage50 V AC
Operating voltage displayYellow LED
Protective circuitBridge rectifier; Bridge rectifier
Protective circuitFilter; Filter

Optocoupler assembly

Nominal input voltage UN120 V AC
Nominal input voltage UN110 V DC
Input voltage range in reference to UN0.85 ... 1.1
Typical input current at UN7 mA (50 Hz)
Typical input current at UN8 mA (60 Hz)
Switching threshold "0" signal in reference to UN≤ 0.4
Typical response time6 ms
Typical release time10 ms
Operating voltage displayYellow LED
Protective circuitBridge rectifier; Bridge rectifier
Protective circuitFilter; Filter

Output data

Compatible componentsMiniature relay, REL-MR-60DC/21AU, REL-MR-60DC/21; miniature optocoupler, OPT-60DC/48DC/100, OPT-60DC/24DC/2, OPT-60DC/230AC/1
Maximum Switching Voltage48 V DC
Minimum Switching Voltage3 V DC
Limiting Continuous Current100 mA
Voltage drop at max. limiting continuous current< 1 V
Output circuit2-conductor, floating
Protective circuitReverse polarity protection
Protective circuitSurge protection
Maximum Switching Voltage30 V DC
Minimum Switching Voltage3 V DC
Limiting Continuous Current3 A
Voltage drop at max. limiting continuous current< 200 mV
Maximum Inrush Current15 A (10 ms)
Output circuit2-conductor, floating
Protective circuitReverse polarity protection
Protective circuitSurge protection
Maximum Switching Voltage253 V AC (Partition plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal points in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum Switching Voltage24 V AC
Limiting Continuous Current0.75 A
Voltage drop at max. limiting continuous current< 1 V
Maximum Inrush Current30 A (10 ms)
Output circuit2-conductor, floating
Protective circuitRCV circuit
Leakage current< 1 mA
Phase angle cos phi min0.5
Max. load value4.5 A2s

Connection data

Connection MethodPush-in connection
Stripping length10 mm
Conductor cross section rigid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm² (Single ferrule)
Conductor cross section flexible2x 0.5 mm² ... 1 mm² (TWIN ferrule)
Conductor cross section AWG26 ... 14

Signaling

Status displayLED

Dimensions

Width6.2 mm
Height80 mm
Depth94 mm

Material specifications

Colorgray (RAL 7042)
Flammability rating according to UL 94V0 (Housing)

Ambient conditions

Ambient Temperature (Operation)-40 °C ... 55 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

CE

CertificateCE-compliant

UKCA

CertificateUKCA-compliant

Shipbuilding approval

CertificateTAE0000196

Corrosive gas test

IdentificationISA-S71.04. G3 Harsh Group
IdentificationEN 60068-2-60

DNV GL data

TemperatureD
HumidityA
VibrationB/C
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Low Voltage DirectiveConformance with Low Voltage Directive
Electromagnetic compatibilityConformance with EMC directive

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsin rows with zero spacing
Mounting Positionany
Accessories

Why Proax for Phoenix Contact 2900453?

Proax is an authorized distributor of Phoenix Contact 2900453 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size10
Recommended
Sold in quantities of 10

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability