SKU
MPN
QUINT-PS/2AC/1DC/24DC/20
Weight
2.027 kg
Series QUINT-PS
QUINT-PS/2AC/1DC/24DC/20 - Power supply unit
Primary-switched DIN rail power supply unit. AC input: suitable for operation between two phases (400 V AC). DC input: suitable for operation in an FI intermediate circuit. Output: 24 V DC/20 A.
- Compact buffer solution
- Fast tripping of standard circuit breakers
- Preventive function monitoring
- Reliable starting of difficult loads and easy system extension
QUINT-PS
The Phoenix Contact QUINT-PS Series is a line of high-performance power supplies designed to ensure maximum system availability in demanding industrial applications. These power supplies are equipped with advanced features such as Selective Fuse Breaking (SFB) Technology, preventive function monitoring, and configurable settings to meet diverse operational requirements.
Key Features:
SFB Technology: The QUINT-PS Series utilizes SFB Technology to deliver up to six times the nominal current for 12 milliseconds, enabling standard circuit breakers to trip selectively. This ensures that only the faulty circuit is disconnected, while critical system components continue to operate without interruption.
Preventive Function Monitoring: These power supplies continuously monitor critical operating parameters and provide early warning signals before faults occur. This proactive approach allows for timely maintenance and reduces the risk of unexpected system downtime.
Power Boost: The QUINT-PS Series offers a static power reserve, known as POWER BOOST, providing up to 125% of the nominal power continuously. This feature facilitates the reliable startup of heavy loads and simplifies system expansion without the need for additional power supplies.
Configurable Settings: Users can customize signaling thresholds and characteristic curves to match specific application needs, enhancing flexibility and adaptability in various industrial environments.
Technical Specifications
AC operation
Nominal input voltage range | 2x 400 V AC ... 500 V AC |
Input voltage range | 2x 360 V AC ... 575 V AC |
Input Voltage Range AC | 2x 360 V AC ... 575 V AC |
Voltage type of supply voltage | AC/DC |
Inrush Current | < 45 A (typical) |
Inrush current integral (I2t) | < 1.5 A2s |
AC frequency range | 45 Hz ... 65 Hz |
Frequency range DC | 0 Hz |
Mains buffering time | typ. 20 ms (400 V AC) |
Current consumption | 2.5 A (400 V AC) |
Current consumption | 2.1 A (500 V AC) |
Nominal Power Consumption | 888 VA |
Protective circuit | Transient surge protection; Varistor |
Input fuse | 3.15 A (slow-blow, internal) |
Recommended breaker for input protection | 10 A ... 16 A (Characteristic B, C) |
DC operation
Nominal input voltage range | 600 V DC |
Input voltage range | 450 V DC ... 840 V DC |
Input voltage range DC | 450 V DC ... 840 V DC |
Voltage type of supply voltage | AC/DC |
Mains buffering time | < 28 ms (600 V DC) |
Current consumption | 0.9 A (600 V DC) |
Protective circuit | Transient surge protection; Varistor |
Permissible backup fuse | 1000 V DC fuse 4 A 6 A |
Output data
Efficiency | > 92 % (600 V DC) |
Efficiency | > 90.5 % (400 V AC) |
Nominal Output Voltage | 24 V DC ±1 % |
Setting range of the output voltage (USet) | 18 V DC ... 29.5 V DC (UIN ≥ 360 V AC / 480 V DC) |
Setting range of the output voltage (USet) | 18 V DC ... 26 V DC (< 480 V DC) |
Nominal output current (IN) | 20 A (-25 °C ... 60 °C) |
POWER BOOST (IBoost) | 26 A (-25 °C ... 40 °C permanent, UOUT = 24 V DC ) |
Selective Fuse Breaking (ISFB) | 120 A (20 ms) |
Magnetic circuit breaker tripping | C6 / B16 |
Derating | 60 °C ... 70 °C (2.5 %/K) |
Feedback voltage resistance | < 35 V DC |
Protection against overvoltage at the output (OVP) | < 35 V DC |
Max. capacitive load | unlimited |
Active current limitation | Approx. 27 A |
Control deviation | < 1 % (change in load, static 10 % ... 90 %) |
Control deviation | < 2 % (change in load, dynamic 10 % ... 90 %) |
Control deviation | < 0.1 % (change in input voltage ±10 %) |
Residual ripple | < 50 mVPP (with nominal values) |
Output Power | 480 W |
Peak switching voltages nominal load | < 50 mVPP (20 MHz) |
Maximum no-load power dissipation | 11 W |
Power loss nominal load max. | 51 W |
Rise time | < 2 ms (UOUT (10 % ... 90 %)) |
Connection in parallel | yes, for redundancy and increased capacity |
Connection in series | yes |
Signal: DC OK floating
Output description | UOUT >0.9 x UN: Relays closed |
Switching voltage range | ≤ 30 V AC/DC |
Maximum Inrush Current | ≤ 100 mA (short-circuit-proof) |
Signal: POWER BOOST, active
Output description | IOUT < IN: High signal |
Switching voltage range | 18 V DC ... 24 V DC |
Maximum Inrush Current | < 20 mA (short-circuit-proof) |
Signal: DCIN OK, active
Output description | UIN >450 V DC: high signal |
Switching voltage range | 18 V DC ... 24 V DC |
Maximum Inrush Current | < 20 mA (short-circuit-proof) |
Input
Connection Method | Screw connection |
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 6 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 4 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 10 |
Stripping length | 8 mm |
Screw thread | M3 |
Tightening torque, min | 0.5 Nm |
Tightening torque max | 0.6 Nm |
Output
Connection Method | Screw connection |
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 6 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 4 mm² |
Conductor cross section AWG min. | 12 |
Conductor cross section AWG max. | 10 |
Stripping length | 8 mm |
Screw thread | M3 |
Tightening torque, min | 0.5 Nm |
Tightening torque max | 0.6 Nm |
Signal
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 6 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 4 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 10 |
Screw thread | M3 |
Tightening torque, min | 0.5 Nm |
Tightening torque max | 0.6 Nm |
Signaling
Types of signaling | LED |
Types of signaling | Relay contact |
Signal output: DC OK floating
Status display | "DC OK" LED green |
Color | green |
Signal output: POWER BOOST, active
Status display | "BOOST" LED yellow/IOUT > IN : LED on |
Color | yellow |
Note on status display | LED on |
Signal output: DCIN OK, active
Status display | LED "DCIN OK" green / UIN > 450 V DC: LED on |
Color | green |
Note on status display | LED on |
Electrical properties
Insulation voltage input/output | 1.5 kV AC (type test) |
Insulation voltage input/output | 2 kV AC (routine test) |
Insulation voltage output / PE | 500 V DC (routine test) |
Insulation voltage input / PE | 4 kV AC (type test) |
Insulation voltage input / PE | 1.5 kV AC (routine test) |
Product properties
Product family | QUINT POWER |
MTBF (IEC 61709, SN 29500) | > 860000 h (40 °C) |
Insulation characteristics
Protection class | I |
Degree of pollution | 2 |
Dimensions
Width | 120 mm |
Height | 130 mm |
Depth | 125 mm |
Installation dimensions
Installation distance right/left | 5 mm / 5 mm |
Installation distance top/bottom | 50 mm / 50 mm |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom |
Mounting Position | horizontal DIN rail NS 35, EN 60715 |
With protective coating | No |
Material specifications
Housing Material | Metal |
Housing Material | Steel sheet, zinc-plated |
Type of housing | Steel sheet, zinc-plated |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Maximum altitude | ≤ 2000 m |
Climatic class | 3K3 (in acc. with EN 60721) |
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
Vibration (Operation) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
Vibration (Operation) | 15 Hz ... 150 Hz, 2.3g, 90 min. |
Standards and Regulations
Rail applications | EN 50121-4 |
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
Standard - Electrical safety | EN 60950-1/VDE 0805 (SELV) |
Standard - Electrical safety | EN 61558-2-17 |
Standard - Safe isolation | DIN VDE 0100-410 |
Standard - Safety of transformers | EN 61558-2-17 |
Approvals
UL approvals | UL/C-UL listed UL 508 |
UL approvals | UL/C-UL Recognized UL 60950-1 |
EMC data
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Accessories
Why Proax for Phoenix Contact 2320830?
Proax is an authorized distributor of Phoenix Contact 2320830 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended