By ABB
SKU
Weight
16.753 kg
Series AF 3-pole Contactor Series
The AF1250-30-11-70 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, switching power circuits up to 1260 A (AC-1) or 1210 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
AF 3-pole Contactor Series
ABB's AF series includes a variety of 3-pole contactors designed for controlling 3-phase motors and power circuits. These contactors are categorized into several sub-series based on their current ratings and applications.
Each sub-series features integrated electronic coils that reduce energy consumption by up to 80%, provide surge protection, and allow operation across wide voltage ranges without coil changes. ABB also offers auxiliary contact blocks and accessories to enhance functionality
Technical Specifications
Dimensions
Product Net Width | 210 mm |
Product Net Depth / Length | 242 mm |
Product Net Height | 344 mm |
Product Net Weight | 14.6 kg |
Technical
Number of Main Contacts NO | 3 |
Number of Main Contacts NC | 0 |
Number of Auxiliary Contacts NO | 1 |
Number of Auxiliary Contacts NC | 1 |
Rated Operational Voltage | Main Circuit 1000 V |
Rated Frequency (f) | Main Circuit 50 / 60 Hz |
Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 1050 A |
Rated Operational Current AC-1 (Ie) | (1000 V) 40 °C 1260 A, (1000 V) 55 °C 1040 A, (1000 V) 70 °C 875 A, (690 V) 40 °C 1260 A, (690 V) 55 °C 1040 A, (690 V) 70 °C 875 A |
Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
Rated Making Capacity AC-3 | 10 x Ie AC-3 |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 7200 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1500 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 4000 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 8000 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 5200 A |
Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 7500 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 7000 A |
Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
Rated Operational Current DC-1 (Ie) | (220 V) 3 Poles in Series, 40 °C 1250 A, (600 V) 3 Poles in Series, 40 °C 1250 A, (850 V) 3 Poles in Series, 40 °C 1250 A |
Rated Operational Current DC-3 (Ie) | (220 V) 3 Poles in Series, 40 °C 1250 A, (600 V) 3 Poles in Series, 40 °C 1250 A, (850 V) 3 Poles in Series, 40 °C 1250 A |
Rated Operational Current DC-5 (Ie) | (220 V) 3 Poles in Series, 40 °C 1250 A, (600 V) 3 Poles in Series, 40 °C 1250 A, (850 V) 3 Poles in Series, 40 °C 1250 A |
Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V, acc. to UL/CSA 600 V |
Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV |
Mechanical Durability | 0.5 million |
Maximum Mechanical Switching Frequency | 300 cycles per hour |
Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
Rated Control Circuit Voltage (Uc) | 50 Hz 100 ... 250 V, 60 Hz 100 ... 250 V, DC Operation 100 ... 250 V |
Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A, Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A, Holding at Max. Rated Control Circuit Voltage DC 5 V·A, Pull-in at Max. Rated Control Circuit Voltage 50 Hz 880 V·A, Pull-in at Max. Rated Control Circuit Voltage 60 Hz 880 V·A, Pull-in at Max. Rated Control Circuit Voltage DC 880 V·A |
Operate Time | Between Coil De-energization and NC Contact Closing 50 ... 70 ms, Between Coil De-energization and NO Contact Opening 53 ... 73 ms, Between Coil Energization and NC Contact Opening 45 ... 115 ms, Between Coil Energization and NO Contact Closing 50 ... 120 ms |
Connecting Capacity Main Circuit | Bar 50 mm² |
Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm², Flexible 2x0.75 ... 2.5 mm², Solid 2 x 1 ... 4 mm², Stranded 1 x 1 .... 4 mm² |
Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
Connecting Terminals (delivered in open position) Main Poles | M 3.5 (+,-) pozidriv 2 screw with cable clamp |
Terminal Type | Main Circuit: Bars |
Technical UL/CSA
Maximum Operating Voltage UL/CSA | Main Circuit 1000 V |
General Use Rating UL/CSA | (1000 V AC) 1210 A |
Environmental
Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C, Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C, Close to Contactor for Storage -40 ... +70 °C |
Maximum Operating Altitude Permissible | Without Derating 3000 m |
Resistance to Shock acc. to IEC 60068-2-27 | Shock Direction: A 5 g, Shock Direction: B1 5 g, Shock Direction: B2 5 g, Shock Direction: C1 5 g, Shock Direction: C2 5 g |
RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
Why Proax for ABB AF1250-30-11-70?
Proax is an authorized distributor of ABB AF1250-30-11-70 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate Names | AF1250301170 |
Pack Size | 1 |
Recommended
- The AF1250-30-11-68 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, switching power circuits up to 1260 A (AC-1) or 1210 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.