The AF116-30-11-33 is a 3 pole - 690 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and double clamp, controlling motors up to 55 kW / 400 V AC (AC-3) or 75 hp / 480 V UL and switching power circuits up to 160 A (AC-1) or 160 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Technical Specifications

Dimensions

Product Net Width90 mm
Product Net Depth / Length142.5 mm
Product Net Height150 mm
Product Net Weight1.55 kg

Technical

Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Rated Operational VoltageMain Circuit 690 V
Rated Frequency (f)Main Circuit 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 160 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 160 A
Rated Operational Current AC-1 (Ie)(690 V) 60 °C 145 A
Rated Operational Current AC-1 (Ie)(690 V) 70 °C 130 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 116 A
Rated Operational Current AC-3 (Ie)(440 V) 55 °C 116 A
Rated Operational Current AC-3 (Ie)(500 V) 55 °C 110 A
Rated Operational Current AC-3 (Ie)(690 V) 55 °C 65 A
Rated Operational Current AC-3 (Ie)(380 / 400 V) 55 °C 116 A
Rated Operational Current AC-3 (Ie)(220 / 230 / 240 V) 55 °C 116 A
Rated Operational Current AC-3e (Ie)(415 V) 60 °C 116 A
Rated Operational Current AC-3e (Ie)(440 V) 60 °C 116 A
Rated Operational Current AC-3e (Ie)(500 V) 60 °C 110 A
Rated Operational Current AC-3e (Ie)(690 V) 60 °C 65 A
Rated Operational Current AC-3e (Ie)(380 / 400 V) 60 °C 116 A
Rated Operational Current AC-3e (Ie)(220 / 230 / 240 V) 60 °C 116 A
Rated Operational Power AC-3 (Pe)(415 V) 55 kW
Rated Operational Power AC-3 (Pe)(440 V) 75 kW
Rated Operational Power AC-3 (Pe)(500 V) 75 kW
Rated Operational Power AC-3 (Pe)(690 V) 55 kW
Rated Operational Power AC-3 (Pe)(380 / 400 V) 55 kW
Rated Operational Power AC-3 (Pe)(220 / 230 / 240 V) 30 kW
Rated Operational Power AC-3e (Pe)(415 V) 55 kW
Rated Operational Power AC-3e (Pe)(440 V) 75 kW
Rated Operational Power AC-3e (Pe)(500 V) 75 kW
Rated Operational Power AC-3e (Pe)(690 V) 55 kW
Rated Operational Power AC-3e (Pe)(380 / 400 V) 55 kW
Rated Operational Power AC-3e (Pe)(220 / 230 / 240 V) 30 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Breaking Capacity AC-3e8.5 x Ie AC-3e
Rated Making Capacity AC-310 x Ie AC-3
Rated Making Capacity AC-3e12 x Ie AC-3e
Short-Circuit Protective DevicesgG Type Fuses 250 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 928 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 379 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1160 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 536 A
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
Maximum Electrical Switching Frequency(AC-2 / AC-4) 150 cycles per hour
Maximum Electrical Switching Frequency(AC-3) 300 cycles per hour
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Insulation Voltage (Ui)acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)8 kV
Mechanical Durability5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 100 ... 250 V
Rated Control Circuit Voltage (Uc)60 Hz 100 ... 250 V
Rated Control Circuit Voltage (Uc)DC Operation 100 ... 250 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 6 V·A
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 60 Hz 6 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage 50 Hz 130 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage 60 Hz 130 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage DC 135 W
Operate TimeBetween Coil De-energization and NO Contact Opening 37 ... 47 ms
Operate TimeBetween Coil Energization and NO Contact Closing 25 ... 55 ms
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Terminal TypeDouble Clamp

Technical UL/CSA

General Use Rating UL/CSA(600 V AC) 160 A
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 15 Hp
Horsepower Rating UL/CSA(200 V AC) Three Phase 30 hp
Horsepower Rating UL/CSA(208 V AC) Three Phase 30 hp
Horsepower Rating UL/CSA(220 ... 240 V AC) Three Phase 20 Hp
Horsepower Rating UL/CSA(220 ... 240 V AC) Three Phase 40 hp
Horsepower Rating UL/CSA(440 ... 480 V AC) Three Phase 40 Hp
Horsepower Rating UL/CSA(440 ... 480 V AC) Three Phase 75 hp
Horsepower Rating UL/CSA(550 ... 600 V AC) Three Phase 50 Hp
Horsepower Rating UL/CSA(550 ... 600 V AC) Three Phase 100 hp

Why Proax for ABB AF116-30-11-33?

Proax is an authorized distributor of ABB AF116-30-11-33 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesAF116301133
Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

ABB Availability