3.9 kg
The AF265-30-22-13 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 132 kW / 400 V AC (AC-3) or 200 hp / 480 V UL and switching power circuits up to 400 A (AC-1) or 350 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories. Includes Mounting kit, containing all neccessary screws, washers and sockets for connecting the terminals, and screws for mounting the device.

AF 3-pole Contactors

ABB's AF series includes a variety of 3-pole contactors designed for controlling 3-phase motors and power circuits. These contactors are categorized into several sub-series based on their current ratings and applications.

Each sub-series features integrated electronic coils that reduce energy consumption by up to 80%, provide surge protection, and allow operation across wide voltage ranges without coil changes. ABB also offers auxiliary contact blocks and accessories to enhance functionality

Technical Specifications

Supplier Information - USINY

Lead Time28 day
Made to OrderNo
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesUSSVCEXPU
Warranty ReturnProduct under warranty must be returned

Dimensions

Product Net Width140 mm
Product Net Depth / Length180 mm
Product Net Height225 mm
Product Net Weight3.9 kg
Dimension Diagram1SFB535001G1060

Technical

Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO2
Number of Auxiliary Contacts NC2
Number of Poles3P
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 400 A
Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 350 A
Rated Operational Current AC-1 (Ie)(1000 V) 55 °C 300 A
Rated Operational Current AC-1 (Ie)(1000 V) 60 °C 300 A
Rated Operational Current AC-1 (Ie)(1000 V) 70 °C 240 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 400 A
Rated Operational Current AC-1 (Ie)(690 V) 55 °C 350 A
Rated Operational Current AC-1 (Ie)(690 V) 70 °C 290 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 265 A
Rated Operational Current AC-3 (Ie)(440 V) 55 °C 265 A
Rated Operational Current AC-3 (Ie)(500 V) 55 °C 250 A
Rated Operational Current AC-3 (Ie)(690 V) 55 °C 250 A
Rated Operational Current AC-3 (Ie)(1000 V) 55 °C 113 A
Rated Operational Current AC-3 (Ie)(380 / 400 V) 55 °C 265 A
Rated Operational Current AC-3 (Ie)(220 / 230 / 240 V) 55 °C 265 A
Rated Operational Current DC-1 (Ie)(110 V) 2 Poles in Series, 40 °C 350 A
Rated Operational Current DC-1 (Ie)(220 V) 3 Poles in Series, 40 °C 350 A
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 40 °C 350 A
Rated Operational Current DC-3 (Ie)(220 V) 3 Poles in Series, 40 °C 350 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 40 °C 350 A
Rated Operational Current DC-5 (Ie)(220 V) 3 Poles in Series, 40 °C 350 A
Rated Operational Power AC-3 (Pe)(415 V) 132 kW
Rated Operational Power AC-3 (Pe)(440 V) 160 kW
Rated Operational Power AC-3 (Pe)(500 V) 160 kW
Rated Operational Power AC-3 (Pe)(690 V) 200 kW
Rated Operational Power AC-3 (Pe)(1000 V) 160 kW
Rated Operational Power AC-3 (Pe)(380 / 400 V) 132 kW
Rated Operational Power AC-3 (Pe)(220 / 230 / 240 V) 75 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Making Capacity AC-310 x Ie AC-3
Short-Circuit Protective DevicesgG Type Fuses 500 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2120 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 400 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 865 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2650 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1224 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3800 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 3300 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Insulation Voltage (Ui)acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
Maximum Electrical Switching Frequency(AC-2 / AC-4) 150 cycles per hour
Maximum Electrical Switching Frequency(AC-3) 300 cycles per hour
Mechanical Durability5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 100 ... 250 V
Rated Control Circuit Voltage (Uc)60 Hz 100 ... 250 V
Rated Control Circuit Voltage (Uc)DC Operation 100 ... 250 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 17.5 V·A
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 60 Hz 17.5 V·A
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage DC 4.5 W
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage 50 Hz 385 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage 60 Hz 385 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage DC 410 W
Power Lossat Rated Operating Conditions per Pole 14 W
Operate TimeBetween Coil De-energization and NO Contact Opening 37 ... 47 ms
Operate TimeBetween Coil Energization and NO Contact Closing 25 ... 55 ms
Connecting Capacity Main CircuitFlexible 2 x 70 ... 185 mm²
Connecting Capacity Main CircuitRigid Al-Cable 1 x 185 ... 240 mm²
Connecting Capacity Main CircuitRigid Cu-Cable 2 x 70 ... 185 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 2x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible 2x0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitSolid 2 x 1 ... 4 mm²
Connecting Capacity Auxiliary CircuitStranded 2 x 1 .... 4 mm²
Connecting CapacityFlexible 2 x 70 ... 185 mm²
Connecting CapacityRigid Al-Cable 1 x 185 ... 240 mm²
Connecting CapacityRigid Cu-Cable 1 x 6 ... 300 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening torqueCable Lug 28 N·m
Tightening torqueMain Circuit 22 ... 43 N·m
Terminal TypeMain Circuit: Bars
Product NameBlock Contactor

Technical UL/CSA

NEMA Size5
Continuous Current Rating NEMA270 A
Horsepower Rating NEMA(200 V AC) Three Phase 75 Hp
Horsepower Rating NEMA(230 V AC) Three Phase 100 Hp
Horsepower Rating NEMA(460 V AC) Three Phase 200 Hp
Horsepower Rating NEMA(575 V AC) Three Phase 200 Hp
Maximum Operating Voltage UL/CSAMain Circuit 1000 V
General Use Rating UL/CSA(1000 V AC) 350 A
Horsepower Rating UL/CSA(200 V AC) Three Phase 75 hp
Horsepower Rating UL/CSA(208 V AC) Three Phase 75 hp
Horsepower Rating UL/CSA(220 ... 240 V AC) Three Phase 100 hp
Horsepower Rating UL/CSA(440 ... 480 V AC) Three Phase 200 hp
Horsepower Rating UL/CSA(550 ... 600 V AC) Three Phase 250 hp
Full Load Amps Motor Use(440 ... 480 V AC) Three Phase 240 A
Full Load Amps Motor Use(550 ... 600 V AC) Three Phase 242 A

ABB EcoSolutions

ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetNon-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions1SFC100112M0002
Environmental Product Declaration - EPD1SFC100104D0201
Environmental Product Declaration - EPD2TFP200030A1001
Improved Energy Efficiency for CustomersProduct Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 76.3 %
Sustainable Material Content in Product (wt. %)Recycled Metal - 33 %

Why Proax for ABB AF265-30-22-13?

Proax is an authorized distributor of ABB AF265-30-22-13 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate NamesAF265302213
Pack Size1
Best Sellersin Contactors

Price N/A

Not in stock

Request lead time or order—we'll ensure quick delivery

ABB Availability