The AFC40-30-00-85 is a 3-pole - 690 V IEC or 600 V UL contactor with Screw terminals, mainly controlling power circuits up to 18.5 kW / 400 V AC (AC-3) or 30 hp / 480 V AC UL and 70 A (AC-1) or 60 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 380 ... 400 V AC 50 Hz / 400 ... 415 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Technical Specifications

Dimensions

Product Net Width55 mm
Product Net Depth / Length119.5 mm
Product Net Height111 mm
Product Net Weight0.98 kg

Technical

Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC0
StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1
Rated Operational VoltageMain Circuit 690 V
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 70 A
Rated Operational Current AC-1 (Ie)(690 V) 60 °C 60 A
Rated Operational Current AC-1 (Ie)(690 V) 70 °C 50 A
Rated Operational Current AC-3 (Ie)(415 V) 60 °C 40 A
Rated Operational Current AC-3 (Ie)(440 V) 60 °C 40 A
Rated Operational Current AC-3 (Ie)(500 V) 60 °C 35 A
Rated Operational Current AC-3 (Ie)(690 V) 60 °C 25 A
Rated Operational Current AC-3 (Ie)(380 / 400 V) 60 °C 40 A
Rated Operational Current AC-3 (Ie)(220 / 230 / 240 V) 60 °C 40 A
Rated Operational Current AC-3e (Ie)(415 V) 60 °C 40 A
Rated Operational Current AC-3e (Ie)(440 V) 60 °C 40 A
Rated Operational Current AC-3e (Ie)(500 V) 60 °C 35 A
Rated Operational Current AC-3e (Ie)(690 V) 60 °C 25 A
Rated Operational Current AC-3e (Ie)(380 / 400 V) 60 °C 40 A
Rated Operational Current AC-3e (Ie)(220 / 230 / 240 V) 60 °C 40 A
Rated Operational Power AC-3 (Pe)(415 V) 22 kW
Rated Operational Power AC-3 (Pe)(440 V) 22 kW
Rated Operational Power AC-3 (Pe)(500 V) 22 kW
Rated Operational Power AC-3 (Pe)(690 V) 22 kW
Rated Operational Power AC-3 (Pe)(380 / 400 V) 18.5 kW
Rated Operational Power AC-3 (Pe)(220 / 230 / 240 V) 11 kW
Rated Operational Power AC-3e (Pe)(415 V) 22 kW
Rated Operational Power AC-3e (Pe)(440 V) 22 kW
Rated Operational Power AC-3e (Pe)(500 V) 22 kW
Rated Operational Power AC-3e (Pe)(690 V) 22 kW
Rated Operational Power AC-3e (Pe)(380 / 400 V) 18.5 kW
Rated Operational Power AC-3e (Pe)(220 / 230 / 240 V) 11 kW
Rated Operational Power AC-6b (Pe)(400 / 415 V) 40 °C, 50 / 60 Hz 26 kvar
Rated Operational Power AC-6b (Pe)(400 / 415 V) 70 °C, 50 / 60 Hz 20 kvar
Rated Operational Power AC-6b (Pe)(400 / 415 V) 55 °C, 50 / 60 Hz 26 kvar
Rated Operational Power AC-6b (Pe)(500 / 550 V), 40 °C, 50 / 60 Hz 35 kvar
Rated Operational Power AC-6b (Pe)(500 / 550 V) 55 °C, 50 / 60 Hz 35 kvar
Rated Operational Power AC-6b (Pe)(500 / 550 V) 70 °C, 50 / 60 Hz 25 kvar
Rated Operational Power AC-6b (Pe)(690 V) 40 °C, 50 / 60 Hz 46 kvar
Rated Operational Power AC-6b (Pe)(690 V) 55 °C, 50 / 60 Hz 46 kvar
Rated Operational Power AC-6b (Pe)(690 V) 70 °C, 50 / 60 Hz 34.5 kvar
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour
Maximum Electrical Switching Frequency(AC-2 / AC-4) 150 cycles per hour
Maximum Electrical Switching Frequency(AC-3) 1200 cycles per hour
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Insulation Voltage (Ui)acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 380 ... 400 V
Rated Control Circuit Voltage (Uc)60 Hz 400 ... 415 V
Coil ConsumptionAverage Holding Value 50 / 60 Hz 20 V·A
Coil ConsumptionAverage Pull-in Value 50 Hz 150 V·A
Coil ConsumptionAverage Pull-in Value 60 Hz 151 V·A
Operate TimeBetween Coil De-energization and NC Contact Closing 6 ... 19 ms
Operate TimeBetween Coil De-energization and NO Contact Opening 4 ... 14 ms
Operate TimeBetween Coil Energization and NC Contact Opening 3 ... 16 ms
Operate TimeBetween Coil Energization and NO Contact Closing 7 ... 21 ms
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting on DIN RailTH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 4 ... 35 mm²
Connecting Capacity Main CircuitFlexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Connecting Capacity Main CircuitRigid 1/2x 6 ... 3 5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Connecting Capacity Control CircuitFlexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Connecting Capacity Control CircuitRigid 1/2x 1 ... 2.5 mm²
Wire Stripping LengthControl Circuit 10 mm
Wire Stripping LengthMain Circuit 16 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Terminal TypeScrew Terminals

Technical UL/CSA

NEMA Size2
Continuous Current Rating NEMA45 A
Horsepower Rating NEMA(115 V AC) Single Phase 3 Hp
Horsepower Rating NEMA(200 V AC) Three Phase 10 Hp
Horsepower Rating NEMA(230 V AC) Single Phase 7-1/2 Hp
Horsepower Rating NEMA(230 V AC) Three Phase 15 Hp
Horsepower Rating NEMA(460 V AC) Three Phase 25 Hp
Horsepower Rating NEMA(575 V AC) Three Phase 25 Hp
Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(600 V AC) 60 A
Horsepower Rating UL/CSA(120 V AC) Single Phase 3 hp
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 10 hp
Horsepower Rating UL/CSA(220 ... 240 V AC) Three Phase 15 hp
Horsepower Rating UL/CSA(240 V AC) Single Phase 7-1/2 hp
Horsepower Rating UL/CSA(440 ... 480 V AC) Three Phase 30 hp
Horsepower Rating UL/CSA(550 ... 600 V AC) Three Phase 40 hp
Tightening Torque UL/CSAControl Circuit 11 in·lb
Tightening Torque UL/CSAMain Circuit 35 in·lb

Why Proax for ABB AFC40-30-00-85?

Proax is an authorized distributor of ABB AFC40-30-00-85 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate NamesAFC40300085
Pack Size1
Best Sellersin Contactors

CAD$271.63

Not in stock

Request lead time or order—we'll ensure quick delivery

ABB Availability