![ABB S201M-C0.5UC](https://proax.ca/images/products/abb/2CDC021031S0011_400x400.jpg)
By ABB
SKU
MPN
2CDS271061R0984
Weight
0.125 kg
The miniature circuit breaker S 200 M UC extends the established
ABB System pro M compact® product range with an MCB for DC and AC applications. The S 200 M UC impresses with its performance range and the accordingly large amount of approvals. Its high inbuilt short circuit breaking capacity across the
entire model line, its flexible AC and DC application and its approval and compliance in accordance with all major international and local standards make it truly unique.
All current System pro M compact® accessories can be combined easily with the new model line. Whether warehousing or project engineering, planning, installing or maintaining your equipment, the S 200 M UC is a simple and flexible solution.
Technical Specifications
Technical
Standards | IEC/EN 60898-2 |
Standards | IEC/EN 60947-2 |
Tripping characteristic | C |
Rated Operational Voltage | acc. to IEC 60898-1 220 V DC |
Rated Operational Voltage | acc. to IEC 60898-1 230 V AC |
Rated Operational Voltage | acc. to IEC 60898-1 220 V |
Rated Operational Voltage | acc. to IEC 60898-2 220 V DC |
Rated Operational Voltage | acc. to IEC 60898-2 230 V AC |
Rated Operational Voltage | acc. to IEC 60947-2 253 V AC |
Rated Operational Voltage | acc. to IEC 60947-2 220 V DC |
Operational Voltage | Maximum (Incl. Tolerance) 250 V DC |
Operational Voltage | Maximum (Incl. Tolerance) 253 V AC |
Operational Voltage | Minimum 12 V AC |
Operational Voltage | Minimum 12 V DC |
Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 440 V |
Rated Impulse Withstand Voltage (Uimp) | 4 kV |
Rated Impulse Withstand Voltage (Uimp) | at 2000 m 5 kV |
Rated Impulse Withstand Voltage (Uimp) | at Sea Level 6.2 kV |
Dielectric Test Voltage | 50/60 Hz, 1 min: 2 kV |
Input Voltage Type | AC/DC |
Rated Current (In) | 0.5 A |
Rated Short-Circuit Capacity | (AC) 10 kA |
Rated Short-Circuit Capacity | (220 V DC) 10 kA |
Rated Short-Circuit Capacity | (230 / 400 V AC) 10 kA |
Rated Short-Circuit Capacity | (230 V AC) 10 kA |
Rated Short-Circuit Capacity | (253 V DC) 10 kA |
Rated Short-Circuit Capacity | (230 V) 10 kA |
Rated Short-Circuit Capacity | (400 V) 10 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (110 V DC) 20 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V DC) 10 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (230 V AC) 10 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (253 V AC) 10 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (230 V) 10 kA |
Rated Conditional Short-Circuit Current (Inc) | (230 V) 10 kA |
Rated Service Short-Circuit Breaking Capacity (Ics) | (110 V DC) 10 kA |
Rated Frequency (f) | 50 / 60 Hz |
Rated Frequency (f) | DC |
Power Loss | 1.29 W |
Power Loss | at Rated Operating Conditions per Pole 1.29 W |
Power supply connection | Please Note Polarity of Device |
Contact Position Indication | Red ON / Green OFF |
Energy Limiting Class | 3 |
Electrical Endurance | 20000 AC cycle |
Mechanical Endurance | 20000 cycle |
Number of Protected Poles | 1 |
Number of Poles | 1 |
Overvoltage category | III |
Tightening torque | 2.8 N·m |
Screw Terminal Type | Failsafe Bi-directional Cylinder-lift Terminal |
Actuator Marking | I / O |
Actuator Material | Insulation Group II, Black, Sealable |
Housing Material | Insulation Group I, RAL 7035 |
Options Provided | Universal current |
Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
Mounting on DIN Rail | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
Mounting Position | any |
Recommended Screw Driver | Pozidriv 2 |
Accessories Available | Yes |
Remarks | Please note polarity of device |
Connecting Capacity | Busbar 10 / 10 mm² |
Connecting Capacity | Flexible with Ferrule 0.75 ... 25 mm² |
Connecting Capacity | Flexible 0.75 ... 25 mm² |
Connecting Capacity | Flexible 0.75 ... 25 mm² |
Connecting Capacity | Rigid 0.75 ... 35 mm² |
Connecting Capacity | Stranded 0.75 ... 35 mm² |
Installation Size | acc. to DIN 43880 1 |
Terminal Type | Screw Terminals |
Technical UL/CSA
Maximum Operating Voltage UL/CSA | 250 V DC |
Maximum Operating Voltage UL/CSA | 480Y/277 V AC |
Interrupting Rating acc. to UL1077 | (110 V DC) 10 kA |
Interrupting Rating acc. to UL1077 | (220 V AC) 10 kA |
Interrupting Rating acc. to UL1077 | (250 V DC) 10 kA |
Interrupting Rating acc. to UL1077 | (253 V AC) 6 kA |
Interrupting Rating acc. to UL1077 | (480Y / 277 V AC) 10 kA |
Connecting Capacity UL/CSA | Busbar 14-8 AWG |
Connecting Capacity UL/CSA | Conductor 14-4 AWG |
Tightening Torque UL/CSA | 25 in·lb |
Dimensions
Width in Number of Modular Spacings | 1 |
Product Net Width | 17.5 mm |
Product Net Height | 85 mm |
Product Net Depth / Length | 69 mm |
Product Net Weight | 0.125 kg |
Pole Net Weight | 0.125 kg |
Built-In Depth (t2) | 69 mm |
Installation
Instructions and Manuals | 2CDS207104P0002 |
Why Proax for ABB S201M-C0.5UC?
Proax is an authorized distributor of ABB S201M-C0.5UC and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate Names | S201MC05UC |
Pack Size | 1 |
Recommended