Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
Weight
0.037 kg
Series SACC-M

SACC-M12MRX-8CT-CL SH - Data connector

Data connector, Ethernet CAT6A (10 Gbps), PROFINET CAT6A (10 Gbps), 8-position, shielded, Plug angled M12, coding: X, Crimp connection, knurl material: Zinc die-cast, tin-plated, external cable diameter 6.5 mm ... 10 mm, without crimp contacts

  • Extremely compact, thanks to the small wiring space and high contact density
  • Safe use in the field, thanks to a high degree of protection
  • Safely shielded: reliable shield connection even under extreme mechanical strain
  • Robust connection: suitable for railway applications with high shock and vibration loads
Technical Specifications

Notes

GeneralThis product corresponds to the PROFINET Cabling and Interconnection Technology Guideline for PROFINET regulations, version 2.00, order no: 2.252, Chapter 8.2 Connectors for Outside Environment (Balanced cabling)
Assembly instruction:NOTE: Observe the permissible bending radii when laying conductors, since the degree of protection may be put in jeopardy if the bending forces are too high. Alleviate mechanical loads upstream of the connector, e.g. by using cable ties.

Mounting

Assembly instructionsContacts can be clipped in place and unclipped without tools
Assembly instructionsThe pin assignment can be rotated in a 30° pitch to the cable outlet

Product properties

ApplicationData
Sensor TypeEthernet
Number of Positions8
No. of cable outlets1
Shieldedyes
CodingX
Cable outletangled

Insulation characteristics

Overvoltage categoryII
Degree of pollution3

Dimensions

Length52 mm
Wrench size, union nut15 mm
Wrench size, counter nut14 mm

External dimensions

Outside diameter6.5 mm ... 10 mm

Housing

Diameter housing16 mm

Material specifications

Flammability rating according to UL 94V0
Seal materialFKM
Material of grip bodyZinc die-cast, nickel-plated
Contact carrier materialPA 6.6
Material for screw connectionZinc die-cast, tin-plated
Standards/regulationsPA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, R24, and R26 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)

Conductor connection

Connection MethodCrimp connection
Connection cross section0.14 mm² ... 0.34 mm² (flexible)
Connection cross section AWG26 ... 22 (flexible)
Stripping length of the individual wire4 mm +0,5 mm
Tightening torque0.4 Nm (M12 knurl)
Tightening torque1.5 Nm (Screw plug insert with sleeve housing as far it will go)
Tightening torque4 Nm (Pressure nut with coupling sleeve)

Pin assignment

Contact | Color (signal designation) | Contact (optional)1 = WHOG (D1+)
Contact | Color (signal designation) | Contact (optional)2 = OG (D1-)
Contact | Color (signal designation) | Contact (optional)3 = WHGN (D2+)
Contact | Color (signal designation) | Contact (optional)4 = GN (D2-)
Contact | Color (signal designation) | Contact (optional)5 = WHBN (D4+)
Contact | Color (signal designation) | Contact (optional)6 = BN (D4-)
Contact | Color (signal designation) | Contact (optional)7 = WHBU (D3-)
Contact | Color (signal designation) | Contact (optional)8 = BU (D3+)

Electrical properties

Rated surge voltage0.8 kV
Insulation resistance≥ 100 Ω
Nominal voltage UN48 V AC
Nominal voltage UN60 V DC
Nominal current IN0.5 A

Mechanical data

Insertion/withdrawal cycles≥ 100

Connection 1

Head designPlug
Head cable outletangled
Head thread typeM12
CodingX

Cable/line

Signal type/categoryEthernet CAT6A (IEC 11801), 10 Gbps
Signal type/categoryPROFINET CAT6A (IEC 11801), 10 Gbps
Stripping length of the individual wire4 mm +0,5 mm

Ambient conditions

Degree of ProtectionIP65
Degree of ProtectionIP67
Ambient Temperature (Operation)-40 °C ... 85 °C (Plug / socket)
Ambient temperature (assembly)-5 °C ... 50 °C

Testing

Standards/regulationsPA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, R24, and R26 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)

M12

Standard designationM12 connector
Standards/specificationsIEC 61076-2-109
Standard designationShock, vibration
Standards/specificationsEN 50155:2001

Why Proax for Phoenix Contact 1422845?

Proax is an authorized distributor of Phoenix Contact 1422845 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability