Official Distributor
By ABB
SKU
MPN
1SAZ911201R1005
Weight
0.612 kg
The TF96-87 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
Technical Specifications
Dimensions
Product Net Width | 69.9 mm |
Product Net Height | 106.9 mm |
Product Net Depth / Length | 106.3 mm |
Product Net Weight | 0.52 kg |
Technical
Setting range | 75 ... 87 A |
Rated Operational Voltage | Auxiliary Circuit 600 V AC/DC |
Rated Operational Voltage | Main Circuit 690 V AC |
Rated Operational Voltage | Main Circuit 440 V DC |
Rated Operational Current (Ie) | 87 A |
Rated Frequency (f) | Auxiliary Circuit 50 Hz |
Rated Frequency (f) | Auxiliary Circuit 60 Hz |
Rated Frequency (f) | Auxiliary Circuit DC |
Rated Frequency (f) | Main Circuit 50 Hz |
Rated Frequency (f) | Main Circuit 60 Hz |
Rated Impulse Withstand Voltage (Uimp) | Auxiliary Circuit 6 kV |
Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV |
Rated Insulation Voltage (Ui) | 690 V |
Number of Poles | 3 |
Number of Auxiliary Contacts NC | 1 |
Number of Auxiliary Contacts NO | 1 |
Number of Protected Poles | 3 |
Conventional Free-air Thermal Current (Ith) | Auxiliary Circuit NC 6 A |
Conventional Free-air Thermal Current (Ith) | Auxiliary Circuit NO 4 A |
Rated Operational Current AC-15 (Ie) | (120 V) NC 3 A |
Rated Operational Current AC-15 (Ie) | (120 V) NO 0.5 A |
Rated Operational Current AC-15 (Ie) | (240 V) NC 3 A |
Rated Operational Current AC-15 (Ie) | (240 V) NO 0.5 A |
Rated Operational Current AC-15 (Ie) | (400 V) NC 0.75 A |
Rated Operational Current AC-15 (Ie) | (400 V) NO 0.5 A |
Rated Operational Current AC-15 (Ie) | (500 V) NC 0.75 A |
Rated Operational Current AC-15 (Ie) | (500 V) NO 0.5 A |
Rated Operational Current DC-13 (Ie) | (125 V) NC 0.55 A |
Rated Operational Current DC-13 (Ie) | (125 V) NO 0.55 A |
Rated Operational Current DC-13 (Ie) | (24 V) NC 1.25 A |
Rated Operational Current DC-13 (Ie) | (24 V) NO 1.25 A |
Rated Operational Current DC-13 (Ie) | (250 V) NC 0.27 A |
Rated Operational Current DC-13 (Ie) | (250 V) NO 0.27 A |
Rated Operational Current DC-13 (Ie) | (500 V) NC 0.15 A |
Rated Operational Current DC-13 (Ie) | (500 V) NO 0.15 A |
Rated Operational Current DC-13 (Ie) | (60 V) NC 0.55 A |
Rated Operational Current DC-13 (Ie) | (60 V) NO 0.55 A |
Degree of Protection | Housing IP20 |
Degree of Protection | Main Circuit Terminals IP10 |
Pollution degree | 3 |
Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
Connecting Capacity Auxiliary Circuit | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² |
Connecting Capacity Auxiliary Circuit | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² |
Connecting Capacity Auxiliary Circuit | Flexible 1/2x 0.75 ... 1 mm² |
Connecting Capacity Auxiliary Circuit | Flexible 1/2x 1 ... 2.5 mm² |
Connecting Capacity Auxiliary Circuit | Rigid 1/2x 0.75 ... 4 mm² |
Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 6 ... 35 mm² |
Connecting Capacity Main Circuit | Flexible with Ferrule 1x 6 ... 50 mm² |
Connecting Capacity Main Circuit | Flexible with Insulated Ferrule 1/2x 6 ... 16 mm² |
Connecting Capacity Main Circuit | Flexible with Insulated Ferrule 1x 6 ... 50 mm² |
Connecting Capacity Main Circuit | Flexible 1/2x 6 ... 35 mm² |
Connecting Capacity Main Circuit | Flexible 1x 6 ... 50 mm² |
Connecting Capacity Main Circuit | Rigid 1/2x 6 ... 35 mm² |
Connecting Capacity Main Circuit | Rigid 1x 6 ... 50 mm² |
Tightening torque | Auxiliary Circuit 1 ... 1.2 N·m |
Tightening torque | Main Circuit 6.0 ... 9.0 N·m |
Wire Stripping Length | Auxiliary Circuit 9 mm |
Wire Stripping Length | Main Circuit 20 mm |
Recommended Screw Driver | Auxiliary Circuit Pozidriv 2 |
Recommended Screw Driver | Main Circuit Hexagon 4 |
Mounting Position | 1 ... 6 |
Power Loss | at Rated Operating Conditions per Pole 2.9 ... 3.9 W |
Suitable for | AF80 |
Suitable for | AF96 |
Standards | IEC/EN 60947-1 |
Standards | IEC/EN 60947-4-1 |
Standards | IEC/EN 60947-5-1 |
Standards | UL 60947-1 |
Standards | UL 60947-4-1 |
Technical UL/CSA
Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
Contact Rating UL/CSA | (NC:) B600 |
Contact Rating UL/CSA | (NC:) Q600 |
Contact Rating UL/CSA | (NO:) Q600 |
Contact Rating UL/CSA | (NO:) D300 |
Connecting Capacity Main Circuit UL/CSA | Flexible 1x 8-1 AWG |
Connecting Capacity Main Circuit UL/CSA | Flexible 2x 8-3 AWG |
Connecting Capacity Main Circuit UL/CSA | Stranded 1x 8-1 AWG |
Connecting Capacity Main Circuit UL/CSA | Stranded 2x 8-3 AWG |
Connecting Capacity Auxiliary Circuit UL/CSA | Flexible 1/2x 18-12 AWG |
Connecting Capacity Auxiliary Circuit UL/CSA | Stranded 1/2x 18-12 AWG |
Tightening Torque UL/CSA | Auxiliary Circuit 9 ... 11 in·lb |
Tightening Torque UL/CSA | Main Circuit 53 ... 80 in·lb |
Why Proax for ABB TF96-87?
Proax is an authorized distributor of ABB TF96-87 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate Names | TF9687 |
Pack Size | 1 |