CHARX SEC-3150 - AC charging controller
CHARX control modular, AC charging controller, with Embedded Linux system, IEC 61851-1, ISO 15118, operating mode: Stand-Alone, Client, Server, interface: Ethernet (2x), Cellular communication (4G/2G), CHARX control modular system bus, MICRO-USB type C, communication protocol: OCPP 1.6J, Modbus/TCP, MQTT, Connectable peripheral devices: Energy meter, RFID, DC residual current detection, DIN rail mounting
Documents
Product properties
Product family | CHARX control modular |
Design | with Embedded Linux system |
Operating mode | Stand-Alone |
Operating mode | Client |
Operating mode | Server |
Charging standard | IEC 61851-1 |
Charging standard | ISO/IEC 15118 |
Charging mode | Mode 3, Case B + C |
Insulation characteristics
Overvoltage category | III |
IEC 61131 runtime system
Data storage system | 8 GByte (eMMC) |
Supply
Supply Voltage | 12 V DC ±5 % |
Supply Voltage Range | 11.4 V DC ... 12.6 V DC |
Max. current consumption | 2 A (Stand-alone operation) |
Digital
Number of digital inputs | 4 |
Description of the input | Digital input |
Nominal input voltage UN | 12 V |
Input voltage range U1 | 0 V ... 3 V (Off) |
Input voltage range U2 | 9 V ... 15 V (On) |
Output name | Digital output |
Number outputs | 4 |
Maximum output voltage | ≤ 12 V (Low-side operation) |
Maximum output current | max. 600 mA |
Conductor connection
Connection Method | pluggable |
Connection Method | Push-in technology |
Conductor cross section rigid | 0.14 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 16 |
Interfaces
Interface | Ethernet (2x) |
Interface | Cellular communication (4G/2G) |
Interface | CHARX control modular system bus |
Interface | USB-C |
Wireless
Interface description | GSM / GPRS / EDGE / LTE (FDD) |
Note | You will find a suitable antenna in the accessories are for this item |
Frequency | 700 MHz (LTE B28, hardware revision 1.4 or later) |
Frequency | 800 MHz (LTE B20) |
Frequency | 900 MHz (LTE B8) |
Frequency | 1800 MHz (LTE B3) |
Frequency | 2100 MHz (LTE B1, hardware revision 1.4 or later) |
Frequency | 2600 MHz (LTE B7, hardware revision 1.4 or later) |
Frequency | 900 MHz (GSM/GPRS/EDGE ) |
Frequency | 1800 MHz (GSM/GPRS/EDGE ) |
Antenna | 50 Ω impedance SMA antenna socket |
SIM Interface | Micro SIM (3FF) |
LTE | CAT1 |
Protocols Supported | OCPP 1.6J |
Ethernet
Interface | Ethernet |
Connection Method | RJ45 jack |
Number of interfaces | 2 |
Number of supported devices | 2 |
Serial transmission speed | 10/100 Mbps |
Transmission length | 100 m |
Protocols Supported | OCPP 1.6J |
Protocols Supported | Modbus/TCP |
Protocols Supported | MQTT |
Protocols Supported | HTTP |
Protocols Supported | HTTPS |
Others
Interface | Configuration and diagnostics |
Connection Method | USB type C |
Number of interfaces | 1 |
Protocols Supported | RNDIS |
Interface | Energy meter |
Bus system | RS-485 |
Transmission speed range | 9.6 kbps ... 115.2 kbps (Automatic setting in accordance with the selected energy meter) |
Interface | RFID readers |
Bus system | RS-485 |
Transmission speed range | 9.6 kbps ... 115.2 kbps (Automatic setting in accordance with the selected RFID reader) |
Interface | CHARX control modular system bus |
Connection Method | DIN rail bus connectors |
Number of interfaces | 1 |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -25 °C ... 65 °C |
Ambient temperature (storage/transport) | -40 °C ... 80 °C |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above mean sea level) |
Air pressure (storage/transport) | 58 kPa ... 106 kPa (up to 4500 m above mean sea level) |
Conformity/Approvals
Conformance | CE-compliant |
Standards
Standards/regulations | IEC 61851-1 |
Standards/regulations | ISO 15118 |
Mounting
Mounting Type | DIN rail mounting |
Assembly note | DIN rail mounting |
Mounting Position | any |
Why Proax for Phoenix Contact 1138965?
Proax is an authorized distributor of Phoenix Contact 1138965 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Pack Size | 1 |
- CHARX control modular, AC charging controller, with Embedded Linux system, IEC 61851-1, ISO 15118, operating mode: Stand-Alone, Client, Server, interface: Ethernet (2x), CHARX control modular system bus, MICRO-USB type C, communication protocol: OCPP 1.6J, Modbus/TCP, MQTT, Connectable peripheral devices: Energy meter, RFID, DC residual current detection, DIN rail mounting
- CHARX connect universal, DC CCS Typ 2, Vehicle charging inlet, up to 500 A in Boost mode, 200 A Permanent, 1000 V DC, Single wires, length: 2 m, locking actuator: 12 V, 4-pos., Front and rear mounting, M6, housing: black, for charging with direct current (DC), IEC 62196-2, IEC 62196-3, A protective cap is supplied as standard for the DC contacts.
- CHARX connect universal, AC/DC CCS Typ 2, Vehicle charging inlet, up to 250 A in Boost mode, 125 A Permanent, 1000 V DC, 32 A , 480 V AC, Single wires, length: 5 m, locking actuator: 12 V, 4-pos., Front and rear mounting, M6, housing: black, for charging with alternating current (AC) and with direct current (DC), IEC 62196-2, IEC 62196-3, A protective cap is supplied as standard for the DC and AC contacts.
- CHARX connect universal, AC/DC CCS Typ 2, Vehicle charging inlet, up to 500 A in Boost mode, 200 A Permanent, 1000 V DC, 32 A , 480 V AC, Single wires, length: 3 m, locking actuator: 12 V, 4-pos., Front and rear mounting, M6, housing: black, for charging with alternating current (AC) and with direct current (DC), IEC 62196-2, IEC 62196-3, A protective cap is supplied as standard for the DC and AC contacts.
- CHARX connect universal, AC/DC CCS Typ 2, Vehicle charging inlet, up to 250 A in Boost mode, 125 A Permanent, 1000 V DC, 32 A , 250 V AC, Single wires, length: 5 m, locking actuator: 12 V, 4-pos., Front and rear mounting, M6, housing: black, for charging with alternating current (AC) and with direct current (DC), IEC 62196-2, IEC 62196-3, A protective cap is supplied as standard for the DC and AC contacts.