AXL P BK PN - Bus coupler

Axioline P, Bus coupler, PROFINET, RJ45 jack, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and connectors

  • 2 Ethernet ports (with integrated switch)
  • PROFINET RT
  • Supports S2 system redundancy
  • Web-based management
  • Hot-swappable
  • Firmware can be updated through Web-based manager
  • High temperature operating range
Technical Specifications

Dimensions

Width45 mm
Height126.93 mm
Depth75 mm
Note on dimensionsThe depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).

Note on application

Note on applicationOnly for industrial use

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area
CCCex noteUse in potentially explosive areas is not permitted in China.

PROFINET

Number of interfaces2
Connection MethodRJ45 jack
Note on the connection methodAuto negotiation and autocrossing
Transmission Speed100 Mbps (full duplex)
Transmission physicsEthernet in RJ45 twisted pair

Axioline P local bus

Number of interfaces1
Connection MethodBus base module
Transmission Speed100 Mbps

System limits

Number of supported devicesmax. 63 (per station)

PROFINET

Device functionPROFINET device
SpecificationVersion 2.3
Conformance classConformance-Class C
Device ID0172hex
Vendor ID00B0hex

Product properties

Product familyAxioline P
Typeblock modular
Mounting Positionany
Scope of deliveryincluding bus base module and connectors

Insulation characteristics

Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Electrical properties

Maximum power dissipation for nominal condition5 W

Potentials: Supply of the bus coupler (UL)

Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 4.15 A (19.2 V DC)
Current drawmax. 3 A (via bus base module)
Current draw125 mA (24 V DC)
Protective circuitSurge protection; electronic
Protective circuitReverse polarity protection; electronic

Potentials: Axioline P local bus supply (UBus)

Supply Voltage5 V DC (via bus base module)
Power Supply Unitmax. 3 A
Current draw3 A (via bus base module)

Electrical isolation/isolation of the voltage ranges

Test voltage: PROFINET interface 1 / PROFINET interface 21500 V AC, 50 Hz, 1 min
Test voltage: PROFINET interface 1 / 24 V communications voltage (UL) feed-in1500 V AC, 50 Hz, 1 min
Test voltage: PROFINET interface 1 / functional ground1500 V AC, 50 Hz, 1 min
Test voltage: PROFINET interface 2 / 24 V communications voltage (UL) feed-in1500 V AC, 50 Hz, 1 min
Test voltage: PROFINET interface 2 / functional ground1500 V AC, 50 Hz, 1 min
Test voltage: 24 V communications voltage (UL) feed-in / functional ground500 V AC, 50 Hz, 1 min

Connection technology

Connection namePower supply
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline P: system and installation” user manual.

Conductor connection

Connection MethodPush-in connection
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Power supply

Connection MethodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline P: system and installation” user manual.
Conductor cross section, rigid0.2 mm² ... 1.5 mm²
Conductor cross section, flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-40 °C ... 70 °C (Mounting position: panel mounting on horizontal DIN rail)
Ambient Temperature (Operation)-40 °C ... 50 °C (Mounting position: any)
Degree of ProtectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 2000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 2000 m above sea level)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

ATEX

Identification II 3 G Ex ec IIC T4 Gc
CertificateIBExU 18ATEXB018 X

IECEx

IdentificationEx ec IIC T4 Gc
CertificateIECEx IBE 18.0023X

UKCA Ex (UKEX)

IdentificationII 3G Ex ec IIC T4 Gc X
CertificatePxCAI22UKEx2316390X

Ex data

UL, USA / CanadaClass I, Div. 2, Groups A, B, C, D T4Class I, Zone 2, IIC T4

Mounting

Mounting TypeDIN rail mounting
Mounting Positionany

Why Proax for Phoenix Contact 1132800?

Proax is an authorized distributor of Phoenix Contact 1132800 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size1
Recommended

CAD$1,782.50

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability