1052429
SKU
PHX1052429
MPN
AXL P AI8 HART 1F
Weight
0.353 kg
Series AXL-P-AI8
AXL P AI8 HART 1F - Analog module
Axioline P, Analog input module, Active analog inputs: 8 (HART), 4 mA ... 20 mA, connection technology: 2-conductor, transmission speed in the local bus: 100 Mbps, HART functionality, degree of protection: IP20
- Active analog input module
- Sources power for up to 8 HART enabled, passive analog input signals
- Connection of sensors in 2-conductor technology
- Current range: 4 mA ... 20 mA
- Can be used under extreme ambient conditions
- Temperature range: -40 °C ... +70 °C
- Hot-swappable
Technical Specifications
Dimensions
| Width | 53.6 mm |
| Height | 126.1 mm |
| Depth | 77.14 mm |
| Note on dimensions | The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715). |
Utilization restriction
| EMC note | EMC: class A product, see manufacturer's declaration in the download area |
| CCCex note | Use in potentially explosive areas is not permitted in China. |
Material specifications
| Color | traffic grey A RAL 7042 |
Axioline P local bus
| Connection Method | Bus base module |
| Transmission Speed | 100 Mbps |
Analog:
| Input name | Active analog inputs |
| Description of the input | HART enabled, passive analog input signals |
| Number of Inputs | 8 (HART) |
| Connection Method | Push-in connection |
| Connection technology | 2-conductor |
| Note regarding the connection technology | shielded, twisted pair |
| Current Input Signal | 4 mA ... 20 mA |
| Protective circuit | Polarity reversal protection of the inputs |
Product properties
| Product family | Axioline P |
| Type | block modular |
| Mounting Position | any (no temperature derating) |
| Special Properties | HART functionality |
Insulation characteristics
| Overvoltage category | II |
| Pollution degree | 2 |
Potentials: Supply of the logic voltage UL
| Supply Voltage Range | 19.2 V DC ... 30 V DC (via bus base module (UL) at AXL P BK...) |
Potentials: Supply of the Axioline P local bus UBus
| Supply Voltage | 5 V DC (via bus base module) |
| Current draw | max. 135 mA |
Potentials: Axioline P extension module supply voltage
| Supply Voltage | UL (via bus base module) |
| Current draw | max. 260 mA (via bus base module) |
Electrical isolation/isolation of the voltage ranges
| Test voltage: 5 V supply of the local bus (UBus) / functional ground | 500 V AC, 62 Hz, 1 min. |
| Test voltage: 24 V supply (I/O) / functional ground | 500 V AC, 62 Hz, 1 min. |
| Test voltage: Field to functional earth | 500 V AC, 62 Hz, 1 min. |
| Test voltage: Field to 5 V and 24 V supplies | 1500 V AC, 62 Hz, 1 min. |
Connection technology
| Connection name | Axioline P connector |
| Note on the connection method | Please observe the information provided on conductor cross sections in the “Axioline P: system and installation” user manual. |
Conductor connection
| Connection Method | Push-in connection |
| Conductor cross section rigid | 0.2 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 1.5 mm² |
| Conductor cross section AWG | 24 ... 16 |
| Stripping length | 8 mm |
Axioline P connector
| Connection Method | Push-in connection |
| Note on the connection method | Please observe the information provided on conductor cross sections in the “Axioline P: system and installation” user manual. |
| Conductor cross section, rigid | 0.2 mm² ... 1.5 mm² |
| Conductor cross section, flexible | 0.2 mm² ... 1.5 mm² |
| Conductor cross section AWG | 24 ... 16 |
| Stripping length | 8 mm |
Ambient conditions
| Degree of Protection | IP20 |
| Ambient Temperature (Operation) | -40 °C ... 70 °C (Standard) |
| Degree of Protection | IP20 |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 2000 m above sea level) |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 2000 m above sea level) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
Standards and Regulations
| Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
ATEX
| Identification | II 3G Ex ec IIC T4 Gc |
| Certificate | DEMKO 20 ATEX 2334X |
IECEx
| Identification | Ex ec IIC T4 Gc |
| Certificate | IECEx UL 20.0002X |
UKCA Ex (UKEX)
| Identification | II 3G Ex ec IIC T4 Gc |
| Certificate | PxCAI22UKEx1052416X |
CCC Ex
| Identification | Ex e ib mb [ia Ga] IIC T4 Gb[Ex iaD] |
| Certificate | 2022122310115622 |
Ex data
| UL, USA / Canada | Class I, Div. 2, Groups A, B, C, D T4Class I, Zone 2, IIC T4 |
Mounting
| Mounting Type | DIN rail mounting |
| Mounting Position | any (no temperature derating) |
Why Proax for Phoenix Contact 1052429?
Proax is an authorized distributor of Phoenix Contact 1052429 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |
Recommended