Official Distributor
SKU
Weight
1.27 kg
Series FL-SWITCH
FL SWITCH 2414-2SFX - Industrial Ethernet Switch
Managed Switch 2000, 14 Ports RJ45 10/100 MBit/s, 2 Ports SFP 100 MBit/s, PROFINET Conformance-Class B, Plage de température élargie, Processus de développement certifié selon la norme CEI 62443-4-1, Compatible avec la norme CEI 62443-4-2
- MRP (client et manager)
- Température ambiante de -40 °C ... 75 °C
- VLAN
- Client DHCP, serveur DHCP (basé sur pool et basé sur port), option DHCP 82
- RSTP
- Gestion basée sur le Web, SNMP
- Mémoire de configuration
- Mise en service et configuration faciles et rapides grâce au logiciel FL NETWORK MANAGER
- Pour réseaux PROFINET et Ethernet/IP™
Technical Specifications
Dimensions
Width | 214 mm |
Height | 113 mm |
Depth | 67 mm |
Notes
General | Support by phone or on-site (fee is charged) |
Material specifications
Material base plate | Die-cast aluminum, corrosion-resistant |
Housing Material | Stainless steel 1.4301 |
Mounting
Mounting Type | DIN rail mounting |
Ethernet (RJ45)
Connection Method | RJ45 |
Note on the connection method | Auto negotiation and autocrossing |
Transmission Speed | 10/100 Mbps |
Transmission physics | Copper |
Transmission length | 100 m (per segment) |
Signal LEDs | Data receive, link status |
No. of channels | 14 (RJ45 ports) |
Ethernet (SFP)
Number of interfaces | 2 |
Connection Method | SFP |
Transmission Speed | 100 Mbps (full duplex) |
Transmission physics | Depending on the SFP module |
Transmission length | up to 40 km (depending on the SFP module used) |
Signal LEDs | Data receive, link status |
No. of channels | 2 (SFP ports) |
Product properties
Product family | Managed Switch 2000 |
Type | Block design |
MTTF | 238.46 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
MTTF | 137.07 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) |
MTTF | 21.04 Years (SN 29500 standard, temperature 70°C, operating cycle 100%) |
Special Properties | Extended temperature range |
Signal delay | ≥ 6.5 µs (Store and Forward mode, 10/100 Mbps, depending on the frame size) |
Insulation characteristics
Protection class | III (VDE 0106) |
Degree of pollution | 2 |
Switch functions
Diagnostic functions | RMON History |
Diagnostic functions | LLDP (Link Layer Discovery Protocol) |
Diagnostic functions | SNMP-Traps |
Diagnostic functions | N:1-Portmirroring |
Diagnostic functions | ACD (Address Conflict Detection) |
Diagnostic functions | SysLog |
Diagnostic functions | CRC-Surveillance |
Basic Functions | Store-and-forward switch, complies with IEEE 802.3 |
Signal contact control voltage | typ. 24 V DC |
PROFINET conformance class | Conformance-Class B |
PROFINET device function | PROFINET device |
PROFINET device function | Fast Startup |
Filter functions | Quality of Service (8 priority classes) |
Filter functions | Class of Service |
Filter functions | DiffServ/DSCP |
Filter functions | Port-Priorisierung |
Filter functions | VLAN (up to 32 VLANs) |
Filter functions | IGMP Snooping/Querier (v1/v2) |
Filter functions | Auto-Query-Port |
Filter functions | Extended Multicast Filtering |
IP parameterization | DHCP-Client |
IP parameterization | DHCP Option 82 (Relay Agent) |
IP parameterization | DHCP server (pool-based, port-based) |
IP parameterization | BootP |
IP parameterization | DCP (Discovery and Configuration Protocol) |
MAC address table | 8k |
Management | Web-based management (HTTP/HTTPS) |
Management | Role-based user management (LDAP, RADIUS) |
Management | SNMPv1/v2/v3 |
Management | Command Line Interface (Telnet, SSH) |
Redundancy | MRP (Media Redundancy Protocol) |
Redundancy | RSTP (Rapid Spanning Tree Protocol) |
Redundancy | FRD (Fast Ring Detection) |
Redundancy | Large Tree Support |
Redundancy | LACP (Link Aggregation Control Protocol) |
Redundancy | PROFINET S2 system redundancy |
Status and diagnostic indicators | LEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (Link/Activity and Speed) |
Additional functions | Transmission of MMS and GOOSE (IEC 61850-8-1) |
Additional functions | Transmission of Modbus/TCP |
Time synchronization | SNTP (Simple Network Time Protocol) |
Security functions
Port security | MAC-based, RADIUS (IEEE 802.1X), MAC Authentication Bypass |
Basic Functions | Store-and-forward switch, complies with IEEE 802.3 |
Electrical properties
Local diagnostics | US1/2 Supply voltage US1, US2 Green LED |
Local diagnostics | FAIL Div. LED red |
Local diagnostics | LNK/ACT Link status Green LED |
Local diagnostics | SPD Data transmission speed Green LED |
Maximum power dissipation for nominal condition | 8.26 W (US = max, Tamb = max) |
Test voltage | 500 V DC |
Test section | for one minute 500 V DC |
Transmission medium | Copper |
Transmission medium | FO |
Supply
Supply voltage (DC) | 24 V DC (redundant) |
Supply Voltage Range | 19.2 V DC ... 32 V DC |
Power supply connection | Via COMBICON, max. conductor cross section 2.5 mm² |
Residual ripple | 3.6 VPP (within the permitted voltage range) |
Max. current consumption | 440 mA (US = min, Tamb = max) |
Typical current consumption | 310 mA (at US = 24 V DC and 25 °C ambient temperature) |
Function
Signal contact control voltage | typ. 24 V DC |
Connection data
Connection Method | Push-in spring connection |
Note on the connection method | Use only copper connecting cables providing the permitted temperature range (-40 °C ... 75 °C). |
Conductor cross section, rigid | 0.2 mm² ... 1.5 mm² |
Conductor cross section, flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 16 |
Stripping length | 10 mm |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -40 °C ... 70 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) |
Shock (operation) | 30g (EN 60068-2-27) |
Vibration (Operation) | in acc. with IEC 60068-2-6: 5g, 150 Hz |
Air pressure (operation) | 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) |
Air pressure (storage/transport) | 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) |
Standards and Regulations
Free from substances that could impair the application of coating | Yes |
UL, USA/Canada
Identification | cULus |
Corrosive gas test
Identification | ISA S71.04.2013 G3 Harsh Group A |
DNV GL data
Temperature | B |
Humidity | B |
Vibration | A |
EMC | B |
Enclosure | Required protection according to the Rules shall be provided upon installation on board |
EMC data
Conformance with EMC directives | EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B |
Conformance with EMC directives | EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion A |
Conformance with EMC directives | EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A |
Conformance with EMC directives | EN 61000-6-2 EN 61000-4-5 (surge) Criterion A |
Conformance with EMC directives | EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A |
Conformance with EMC directives | EN 61000-6-2 EN 61000-6-4 (interference) Class A |
Conformance with EMC directives | EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A |
Noise immunity | EN 61000-6-2 |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Noise emission | EN 61000-6-4 |
Functionality
Basic Functions | Store-and-forward switch, complies with IEEE 802.3 |
Signaling
Status display | LEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (Link/Activity and Speed) |
Why Proax for Phoenix Contact 1043423?
Proax is an authorized distributor of Phoenix Contact 1043423 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |