Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
Weight
1.27 kg
Series FL-SWITCH

FL SWITCH 2416 - Industrial Ethernet Switch

Managed Switch 2000, 16 RJ45 ports 10/100 Mbps, PROFINET Conformance-Class B, Extended temperature range

  • DHCP client, DHCP server (pool-based and port-based), DHCP option 82
  • Ambient temperature -40 °C ... 70 °C
  • VLANs
  • RSTP
  • MRP (client and manager)
  • Web-based management, SNMP
  • Configuration memory
  • Easy and fast startup and commissioning with the FL NETWORK MANAGER software
  • Suitable for PROFINET and EtherNet/IP™ networks
Technical Specifications

Dimensions

Width214 mm
Height113 mm
Depth67 mm

Notes

GeneralSupport by phone or on-site (fee is charged)

Material specifications

Material base plateDie-cast aluminum, corrosion-resistant
Housing MaterialStainless steel 1.4301

Mounting

Mounting TypeDIN rail mounting

Ethernet (RJ45)

Connection MethodRJ45
Note on the connection methodAuto negotiation and autocrossing
Transmission Speed10/100 Mbps
Transmission physicsCopper
Transmission length100 m (per segment)
Signal LEDsData receive, link status
No. of channels16 (RJ45 ports)

Product properties

Product familyManaged Switch 2000
TypeBlock design
MTTF238.46 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
MTTF137.07 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
MTTF21.04 Years (SN 29500 standard, temperature 70°C, operating cycle 100%)
Special PropertiesExtended temperature range
Signal delay≥ 6.5 µs (Store and Forward mode, 10/100 Mbps, depending on the frame size)

Insulation characteristics

Protection classIII (VDE 0106)
Degree of pollution2

Switch functions

Diagnostic functionsRMON History
Diagnostic functionsLLDP (Link Layer Discovery Protocol)
Diagnostic functionsSNMP-Traps
Diagnostic functionsN:1-Portmirroring
Diagnostic functionsACD (Address Conflict Detection)
Diagnostic functionsSysLog
Diagnostic functionsCRC-Surveillance
Basic FunctionsStore-and-forward switch, complies with IEEE 802.3
Signal contact control voltagetyp. 24 V DC
PROFINET conformance classConformance-Class B
PROFINET device functionPROFINET device
PROFINET device functionFast Startup
Filter functionsQuality of Service (8 priority classes)
Filter functionsClass of Service
Filter functionsDiffServ/DSCP
Filter functionsPort-Priorisierung
Filter functionsVLAN (up to 32 VLANs)
Filter functionsIGMP Snooping/Querier (v1/v2)
Filter functionsAuto-Query-Port
Filter functionsExtended Multicast Filtering
IP parameterizationDHCP-Client
IP parameterizationDHCP Option 82 (Relay Agent)
IP parameterizationDHCP server (pool-based, port-based)
IP parameterizationBootP
IP parameterizationDCP (Discovery and Configuration Protocol)
MAC address table8k
ManagementWeb-based management (HTTP/HTTPS)
ManagementRole-based user management (LDAP, RADIUS)
ManagementSNMPv1/v2/v3
ManagementCommand Line Interface (Telnet, SSH)
RedundancyMRP (Media Redundancy Protocol)
RedundancyRSTP (Rapid Spanning Tree Protocol)
RedundancyFRD (Fast Ring Detection)
RedundancyLarge Tree Support
RedundancyLACP (Link Aggregation Control Protocol)
RedundancyPROFINET S2 system redundancy
Status and diagnostic indicatorsLEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (Link/Activity and Speed)
Additional functionsTransmission of MMS and GOOSE (IEC 61850-8-1)
Additional functionsTransmission of Modbus/TCP
Time synchronizationSNTP (Simple Network Time Protocol)

Security functions

Port securityMAC-based, RADIUS (IEEE 802.1X), MAC Authentication Bypass
Basic FunctionsStore-and-forward switch, complies with IEEE 802.3

Electrical properties

Local diagnosticsUS1/2 Supply voltage US1, US2 Green LED
Local diagnosticsFAIL Div. LED red
Local diagnosticsLNK/ACT Link status Green LED
Local diagnosticsSPD Data transmission speed Green LED
Maximum power dissipation for nominal condition7.52 W (US = max, Tamb = max)
Test voltage500 V DC
Test sectionfor one minute 500 V DC
Transmission mediumCopper

Supply

Supply voltage (DC)24 V DC (redundant)
Supply Voltage Range19.2 V DC ... 32 V DC
Power supply connectionVia COMBICON, max. conductor cross section 2.5 mm²
Residual ripple3.6 VPP (within the permitted voltage range)
Max. current consumption390 mA (US = min, Tamb = max)
Typical current consumption280 mA (at US = 24 V DC and 25 °C ambient temperature)

Function

Signal contact control voltagetyp. 24 V DC

Connection data

Connection MethodPush-in spring connection
Note on the connection methodUse only copper connecting cables providing the permitted temperature range (-40 °C ... 75 °C).
Conductor cross section, rigid0.2 mm² ... 1.5 mm²
Conductor cross section, flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 16
Stripping length10 mm

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)10 % ... 95 % (non-condensing)
Shock (operation)30g (EN 60068-2-27)
Vibration (Operation)in acc. with IEC 60068-2-6: 5g, 150 Hz
Air pressure (operation)79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating)
Air pressure (storage/transport)79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating)

Standards and Regulations

Free from substances that could impair the application of coatingYes

UL, USA/Canada

IdentificationcULus

Corrosive gas test

IdentificationISA S71.04.2013 G3 Harsh Group A

DNV GL data

TemperatureB
HumidityB
VibrationA
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Conformance with EMC directivesEN 61000-6-2 EN 61000-4-2 (ESD) Criterion B
Conformance with EMC directivesEN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion A
Conformance with EMC directivesEN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A
Conformance with EMC directivesEN 61000-6-2 EN 61000-4-5 (surge) Criterion A
Conformance with EMC directivesEN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A
Conformance with EMC directivesEN 61000-6-2 EN 61000-6-4 (interference) Class A
Conformance with EMC directivesEN 61000-6-2 EN 61000-6-4 (conducted interference) Class A
Noise immunityEN 61000-6-2
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Noise emissionEN 61000-6-4

Functionality

Basic FunctionsStore-and-forward switch, complies with IEEE 802.3

Signaling

Status displayLEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (Link/Activity and Speed)

Why Proax for Phoenix Contact 1043416?

Proax is an authorized distributor of Phoenix Contact 1043416 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability