Official Distributor
SKU
MPN
QUINT4-PS/12-24DC/24DC/2.5/SC
Weight
0.321 kg
This product is Not Cancellable/Not Returnable
Series QUINT4-PS
QUINT4-PS/12-24DC/24DC/2.5/SC - DC/DC converter
Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, input: 12 V DC - 24 V DC, output: 24 V DC / 2.5 A
- Most powerful output side: easy system expansion, reliable heavy load startup and miniature circuit breaker tripping
- Most comprehensive signaling: preventive function monitoring reports critical operating states before errors occur
- Free selection between Push-in and screw connection
Technical Specifications
Input data
Nominal input voltage range | 12 V DC ... 24 V DC |
Input voltage range | 12 V DC ... 24 V DC -25 % ... +33 % (SELV) |
Wide-range input | yes |
Electric strength, max. | 35 V DC (60 s) |
Inrush Current | typ. 8.6 A |
Inrush current integral (I2t) | typ. 0.1 A2s |
Inrush current limitation | 8.6 A |
Mains buffering time | typ. 16 ms (24 V DC) |
Current consumption | typ. 7.2 A (12 V DC) |
Current consumption | typ. 3.5 A (24 V DC) |
Switch-on time | < 1 s |
Input fuse | 15 A (fast blow, internal) |
Recommended breaker for input protection | 10 A ... 16 A (Characteristic B, C, D, K or comparable) |
Output data
Efficiency | typ. 92.1 % (24 V DC) |
Output characteristic | U/I Advanced |
Output characteristic | Smart HICCUP |
Output characteristic | FUSE MODE |
Nominal Output Voltage | 24 V DC |
Setting range of the output voltage (USet) | 24 V DC ... 28 V DC (> 24 V DC, constant capacity) |
Nominal output current (IN) | 2.5 A |
Static Boost (IStat.Boost) | 3.125 A (≤ 40 °C) |
Dynamic Boost (IDyn.Boost) | 5 A (≤ 60 °C (4.9 s)) |
Short-circuit-proof | yes |
No-load proof | yes |
Derating | > 60 °C (2.5%/K of POut nom.) |
Output power (PN) | 60 W |
Output power (PStat. Boost) | 75 W |
Output power (PDyn. Boost) | 120 W |
Feedback voltage resistance | ≤ 35 V DC |
Protection against overvoltage at the output (OVP) | ≤ 32 V DC |
Residual ripple | < 20 mVPP |
Control deviation | < 1 % (change in load, static 10 % ... 90 %) |
Control deviation | < 1 % (change in load, static 10 % ... 90 %) |
Control deviation | < 1 % (change in load, static 10 % ... 90 %) |
Rise time | < 1 s (UOUT (10 % ... 90 %)) |
Connection in series | yes |
Maximum no-load power dissipation | < 1.3 W |
Power loss nominal load max. | < 8 W |
Connection in parallel | yes, for redundancy and increased capacity |
Signal (configurable)
Digital | 0 V DC |
Digital | 24 V DC |
Digital | 22 mA |
Default | 24 V DC |
Default | 22 mA |
Default | 24 V DC for UOut > 0.9 x USet |
Input
Position | 1.x |
Conductor connection
Connection Method | Screw connection |
rigid | 0.75 mm² ... 2.5 mm² |
flexible | 0.75 mm² ... 2.5 mm² |
flexible with ferrule without plastic sleeve | 0.75 mm² ... 2.5 mm² |
flexible with ferrule with plastic sleeve | 0.75 mm² ... 2.5 mm² |
rigid (AWG) | 18 ... 14 |
Stripping length | 8 mm |
Tightening torque | 0.5 Nm ... 0.6 Nm |
Drive form screw head | Slotted L |
Output
Position | 2.x |
Conductor connection
Connection Method | Screw connection |
rigid | 0.5 mm² ... 2.5 mm² |
flexible | 0.5 mm² ... 2.5 mm² |
flexible with ferrule without plastic sleeve | 0.5 mm² ... 2.5 mm² |
flexible with ferrule with plastic sleeve | 0.5 mm² ... 2.5 mm² |
rigid (AWG) | 20 ... 14 |
Stripping length | 8 mm |
Tightening torque | 0.5 Nm ... 0.6 Nm |
Drive form screw head | Slotted L |
Signal
Position | 3.x |
Conductor connection
Connection Method | Screw connection |
rigid | 0.14 mm² ... 2.5 mm² |
flexible | 0.14 mm² ... 2.5 mm² |
flexible with ferrule without plastic sleeve | 0.2 mm² ... 2.5 mm² |
flexible with ferrule with plastic sleeve | 0.25 mm² ... 2.5 mm² |
rigid (AWG) | 26 ... 14 |
Stripping length | 8 mm |
Tightening torque | 0.5 Nm ... 0.6 Nm |
Drive form screw head | Slotted L |
LED signaling
Signal threshold | > PThr (LED lights up yellow, output power > PThr, depending on the rotary selector switch setting) |
Signal threshold | > 0.9 x USet (LED lights up green) |
Signal threshold | < 0.9 x USet (LED flashes green) |
Electrical properties
Number of phases | 1.00 |
Insulation voltage input/output | 2.6 kV DC (type test) |
Insulation voltage input/output | 1.2 kV DC (routine test) |
Switching frequency | 130.00 kHz ... 130.00 kHz (Auxiliary converter stage) |
Switching frequency | 70.00 kHz ... 250.00 kHz (Main converter stage) |
Product properties
Product family | QUINT POWER |
MTBF (IEC 61709, SN 29500) | > 1999348 h (25 °C) |
MTBF (IEC 61709, SN 29500) | > 1120490 h (40 °C) |
MTBF (IEC 61709, SN 29500) | > 471066 h (60 °C) |
Insulation characteristics
Protection class | II |
Degree of pollution | 2 |
Life expectancy (electrolytic capacitors)
Current | 1.25 A |
Temperature | 40 °C |
Time | 242000 h |
Additional text | 24 V DC |
Current | 2.5 A |
Temperature | 40 °C |
Time | 160000 h |
Additional text | 24 V DC |
Current | 2.5 A |
Temperature | 30 °C |
Time | 320000 h |
Additional text | 24 V DC |
Item dimensions
Width | 32 mm |
Height | 99 mm |
Depth | 90 mm |
Item dimensions with alternative mounting
Width | 90 mm |
Height | 99 mm |
Depth | 32 mm |
Installation dimensions
Installation distance right/left (active) | 15 mm / 15 mm (POut ≥50% ) |
Installation distance right/left (passive) | 5 mm / 5 mm (POut ≥50% ) |
Installation distance right/left (active, passive) | 0 mm / 0 mm (POut ≤50 %) |
Installation distance top/bottom (active) | 30 mm / 30 mm (POut ≥50% ) |
Installation distance top/bottom (passive) | 30 mm / 30 mm (POut ≥50% ) |
Installation distance top/bottom (active, passive) | 30 mm / 30 mm (POut ≤50 %) |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom |
With protective coating | No |
Material specifications
Flammability rating according to UL 94 (housing / terminal blocks) | V0 |
Housing Material | Plastic |
Type of housing | Polycarbonate (PC), UL 94 V0 |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Ambient temperature (start-up type tested) | -40 °C |
Maximum altitude | ≤ 5000 m (> 2000 m, observe derating) |
Climatic class | 3K3 (in acc. with EN 60721) |
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
Vibration (Operation) | < 15 Hz, ±2.5 mm amplitude; 15 Hz ... 100 Hz: 2.3 g 90 Min. (in accordance with IEC 60068-2-6) |
Overvoltage category
EN 61010-1 | II (≤ 5000 m) |
Safety for measurement, control, and laboratory equipment
Standard designation | Electrical safety (of control and regulation devices) |
Standards/specifications | IEC 61010-1 |
Protective extra-low voltage
Standard designation | Protective extra-low voltage |
Standards/specifications | IEC 61010-1 (SELV) |
Mains voltage dips
Standard designation | Mains variation/undervoltage |
Standards/specifications | EN 61000-4-29 |
Approvals
SIQ | CB-Scheme (IEC 61010-1, IEC 61010-2-201) |
UL approvals | UL Listed UL 61010-1 |
UL approvals | UL Listed UL 61010-2-201 |
UL approvals | ANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location) |
UL
Identification | UL Listed UL 61010-1 |
Identification | CAN/CSA C22.2 No. 61010-1-12 |
Identification | UL Listed UL 61010-2-201 |
Identification | CAN/CSA C22.2 No. 61010-2-201:18 |
Identification | UL 121201 & CSA C22.2 No. 213-17 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location) |
CB scheme
Identification | IEC 61010-1 |
Identification | IEC 61010-2-201 |
Shipbuilding
Identification | DNV GL |
EMC data
EMC requirements for noise emission | EN 61000-6-3 |
EMC requirements for noise emission | EN 61000-6-4 |
EMC requirements for noise immunity | EN 61000-6-1 |
EMC requirements for noise immunity | EN 61000-6-2 |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
EMC requirements, power plant | EN 61850-3 |
EMC requirements, power plant | EN 61000-6-5 |
Conducted noise emission | EN 55016 |
Conducted noise emission | EN 61000-6-3 (Class B) |
Noise emission | Additional basic standard EN 61000-6-5 (immunity in power station), IEC/EN 61850-3 (energy supply) |
Noise emission | EN 55016 |
Noise emission | EN 61000-6-3 (Class B) |
DNV GL conducted interference | Class B |
Additional text | Bridge and deck area |
DNV GL noise radiation | Class B |
Additional text | Bridge and deck area |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Contact discharge | 6 kV (Test Level 4) |
Discharge in air | 8 kV (Test Level 3) |
Comments | Criterion A |
Electromagnetic HF field
Standards/regulations | EN 61000-4-3 |
Frequency Range | 80 MHz ... 1 GHz |
Test field strength | 20 V/m (Test Level 3) |
Frequency Range | 1 GHz ... 6 GHz |
Test field strength | 10 V/m (Test Level 3) |
Comments | Criterion A |
Fast transients (burst)
Standards/regulations | EN 61000-4-4 |
Input | 2 kV (Test Level 4 - asymmetrical) |
Output | 2 kV (Test Level 4 - asymmetrical) |
Signal | 2 kV (Test Level 4 - asymmetrical) |
Comments | Criterion B |
Surge voltage load (surge)
Standards/regulations | EN 61000-4-5 |
Input | 0.5 kV (Test Level 3 - symmetrical) |
Input | 1 kV (Test Level 3 - asymmetrical) |
Output | 0.5 kV (Test Level 2 - symmetrical) |
Output | 1 kV (Test Level 1 - asymmetrical) |
Signal | 0.5 kV (Test Level 2 - symmetrical) |
Signal | 1 kV (Test Level 1 - asymmetrical) |
Comments | Criterion B |
Conducted interference
Standards/regulations | EN 61000-4-6 |
I/O/S | asymmetrical |
Frequency Range | 0.15 MHz ... 80 MHz |
Comments | Criterion A |
Voltage | 10 V (Test Level 3) |
Power frequency magnetic field
Standards/regulations | EN 61000-4-8 |
Frequency | 16.67 Hz |
Frequency | 50 Hz |
Frequency | 60 Hz |
Test field strength | 100 A/m |
Additional text | 60 s |
Comments | Criterion A |
Frequency | 50 Hz |
Frequency | 60 Hz |
Frequency Range | 50 Hz ... 60 Hz |
Test field strength | 1 kA/m |
Additional text | 3 s |
Frequency | 0 Hz |
Test field strength | 300 A/m |
Additional text | DC, 60 s |
Voltage dips
Standards/regulations | EN 61000-4-29 |
Voltage | 24 V DC |
Voltage dip | 70 % |
Number of periods | 0.5 / 1 / 25 periods |
Time | 100 ms |
Additional text | Test Level 2 |
Comments | Criterion A |
Voltage dip | 40 % |
Number of periods | 5 / 10 / 50 periods |
Time | 100 ms |
Additional text | Test Level 2 |
Comments | Criterion A |
Voltage dip | 0 % |
Number of periods | 0.5 / 1 / 5 / 50 periods |
Time | 50 ms |
Additional text | Test Level 2 |
Comments | Criterion B |
Pulse-shape magnetic field
Standards/regulations | EN 61000-4-9 |
Test field strength | 1000 A/m |
Comments | Criterion A |
Asymmetrical conducted disturbance variables
Standards/regulations | EN 61000-4-16 |
Test level 1 | 15 Hz 150 Hz (Test Level 3) |
Voltage | 10 V 1 V (Permanent) |
Test level 2 | 150 Hz 1.5 kHz (Test Level 3) |
Voltage | 1 V |
Test level 3 | 1.5 kHz 15 kHz (Test Level 3) |
Voltage | 1 V 10 V |
Test level 4 | 15 kHz 150 kHz (Test Level 3) |
Voltage | 10 V |
Test level 5 | 16.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3) |
Voltage | 10 V (Permanent) |
Test level 6 | 0 Hz 16.7 Hz 50 Hz 60 Hz (Test Level 3) |
Voltage | 100 V (1 s) |
Comments | Criterion A |
Alternating component of direct voltage
Standards/regulations | EN 61000-4-17 |
Alternating component | 10 % (UN) |
Frequency | 50 Hz |
Frequency | 100 Hz |
Frequency | 150 Hz |
Frequency | 300 Hz |
Comments | Criterion A |
Attenuated oscillating wave
Standards/regulations | EN 61000-4-18 |
Input, output (test level 1) | 1 MHz (Test Level 2 - symmetrical) |
Voltage | 0.5 kV |
Input, output (test level 2) | 1 MHz (Test Level 2 - asymmetrical) |
Voltage | 1 kV |
Signals (test level 1) | 1 MHz (Test Level 2 - symmetrical) |
Voltage | 0.5 kV |
Signals (test level 2) | 1 MHz (Test Level 2 - asymmetrical) |
Voltage | 1 kV |
Comments | Criterion A |
Attenuated oscillating magnetic field
Standards/regulations | EN 61000-4-10 |
Test field strength | 100 A/m |
Test level 1 | 100 kHz |
Test field strength | 100 A/m |
Test level 2 | 1 MHz |
Comments | Criterion A |
Criteria
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Criterion C | Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements. |
Why Proax for Phoenix Contact 1066718?
Proax is an authorized distributor of Phoenix Contact 1066718 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended