By ABB
SKU
MPN
1SCA161293R1001
Weight
8.943 kg
ABB offers new OTDC Switch-disconnectors specially designed for reliable switching for ESS applications were higher performance is needed. They are durable and virtually maintenance-free, and offer easy installation for all imaginable situations.
Depending on the ESS layout and the customer’s wishes, the OTDC switch-disconnectors may be used in one or more sections of the overall setup, for the battery protection.
Main characteristics of this particular OTDC type:
Rated conditional short circuit current with fuses is 30kA, 4-Pole, 1500Vdc, Approved according to UL98B and IEC 60947-1,-3
Technical Specifications
Dimensions
Product Frame Size | M |
Product Net Width | 196.2 mm |
Product Net Width | 7.7 in |
Product Net Height | 211 mm |
Product Net Height | 8.3 in |
Product Net Depth / Length | 148 mm |
Product Net Depth / Length | 5.8 in |
Product Net Weight | 9.7 kg |
Product Net Weight | 21.3 lb |
Technical
Connection configuration | Single circuit 6c, 6g |
Rated Operational Current DC-21B (Ie) | (1500 V) 1000 A |
Conventional Free-air Thermal Current (Ith) | Θ = 40 °C 1000 A |
Rated Impulse Withstand Voltage (Uimp) | 12 kV |
Rated Operational Voltage | 1500 V |
Rated Short-Circuit Making Capacity (Icm) | (1500 V DC) 63 kA |
Rated Short-time Withstand Current Low Voltage (Icw) | (1500 V DC) 10 kA |
Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 10 kA |
Rated Short-time Withstand Current Low Voltage (Icw) | for 0.1 s 63 kA |
Rated Conditional Short-Circuit Current (Inc) | (1500 V DC) 100 kA |
Protection Type | Circuit breaker or a fuse selected from the fuse coordination table. For the coordination tables (9AKK108467A9503 & 9AKK108467A9504) please see the section Instructions and Manuals. |
Power Loss | at Rated Operating Conditions per Pole 30...32 W |
Handle Type | Handle and shaft not included |
Positive Opening Operation Torque (Direct Opening Action) | 18 … 30 N·m |
Shaft Diameter | 12 mm |
Shaft Diameter | 0.47 in |
Switches Operating Mechanism | Mechanism Between the Poles |
Switches Operating Mechanism | 22 (Between the Poles) |
Position of Line Terminals | Top In - Bottom Out |
Position of Line Terminals | Bottom In - Top Out |
Operating mode | Front Operated |
Standards | UL98B and IEC 60947-1, -3 |
Special Functions | No |
Mounting Type | Base Mounting |
Number of Circuits | 1 |
Number of Poles | 4 |
Terminal Type | Lug terminals |
Terminal Width | 30 mm |
Terminal Width | 1.2 in |
Tightening torque | Cable Lug 50 … 75 N·m |
Tightening torque | Cable Lug 443 … 664 lbf·in |
Utilization | Energy Storage System (ESS) |
Utilization category | Switching of resistive loads, including moderate overloads - occasional actuation (DC-21B) |
Utilization category | Switching of single PV string(s) without reverse and overcurrents (DC-PV1) |
Technical UL/CSA
Maximum Operating Voltage | 1500Vdc, UL 98B |
Ampere Rating | 1000A,1500Vdc,UL98B |
Short-circuit current rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers 40 kA |
Short-circuit current rating (SCCR) | Fuse, see Catalog 50 kA |
Tightening torque | Cable Lug 50 … 75 N·m |
Tightening torque | Cable Lug 443 … 664 lbf·in |
Why Proax for ABB OTDC1000UFV22-ESS?
Proax is an authorized distributor of ABB OTDC1000UFV22-ESS and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.