OTDC400UFV11-ESS
By ABB
SKU
ABBOTDC400UFV11ESS
MPN
1SCA158216R1001
Weight
3.5 kg
ABB offers new OTDC Switch-disconnectors specially designed for reliable switching for ESS applications were higher performance is needed. They are durable and virtually maintenance-free, and offer easy installation for all imaginable situations.
Depending on the ESS layout and the customer’s wishes, the OTDC switch-disconnectors may be used in one or more sections of the overall setup, for the battery protection.
Main characteristics of this particular OTDC type:
Rated conditional short circuit current with fuses is 30kA, 2-Pole, 1500Vdc, Approved according to UL98B and IEC 60947-1,-3
Technical Specifications
ABB EcoSolutions
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 1SCC301112M0201 |
| Environmental Product Declaration - EPD | 1SCC301247D0201 |
| Improved Energy Efficiency for Customers | Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 59,09 % |
Dimensions
| Product Frame Size | M |
| Product Net Width | 157.5 mm |
| Product Net Width | 6.2 in |
| Product Net Height | 211 mm |
| Product Net Height | 8.3 in |
| Product Net Depth / Length | 135 mm |
| Product Net Depth / Length | 5.3 in |
| Product Net Weight | 3.5 kg |
| Product Net Weight | 7.7 lb |
Technical
| Connection configuration | Single circuit 2a, 2b |
| Conventional Free-air Thermal Current (Ith) | Θ = 40 °C 500 A |
| Conventional Thermal Current (Ithe) | Fully Enclosed 500 A |
| Degree of Protection | Front IP20 |
| Handle Type | Handle and shaft not included |
| Mechanical Durability | 10000 cycle |
| Mounting Type | Base mounting |
| Number of Circuits | 1 |
| Number of Poles | 2P |
| Operating mode | Front |
| Pollution degree | 3 |
| Position of Line Terminals | Top In - Bottom Out |
| Position of Line Terminals | Bottom In - Top Out |
| Positive Opening Operation Torque (Direct Opening Action) | 11 … 19 N·m |
| Power Loss | at Rated Operating Conditions per Pole 18 ... 20 W |
| Protection Type | Circuit breaker or a fuse selected from the fuse coordination table. For the coordination tables (9AKK108467A9503 & 9AKK108467A9504) please see the section Instructions and Manuals. |
| Rated Conditional Short-Circuit Current (Inc) | (1500 V DC) 100 kA |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1500 V |
| Rated Operational Current DC-21B (Ie) | (1500 V) 500 A |
| Rated Operational Current DC-22B | (1500 V) 400 A |
| Rated Operational Current DC-PV1 | (1500 V) 500 A |
| Rated Operational Current DC-PV2 | (1500 V) 400 A |
| Rated Operational Voltage | 1500 V |
| Rated Short-Circuit Making Capacity (Icm) | (1500 V DC) 20 kA |
| Rated Short-time Withstand Current Low Voltage (Icw) | (1500 V DC) 10 kA |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 10 kA |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 0.1 s 20 kA |
| Shaft Diameter | 12 mm |
| Shaft Diameter | 0.47 in |
| Special Functions | No |
| Standards | UL98B and IEC 60947-1, -3 |
| Switches Operating Mechanism | Mechanism Between the Poles |
| Switches Operating Mechanism | 11 (Between the Poles) |
| Terminal Type | Lug terminals |
| Terminal Width | 30 mm |
| Terminal Width | 1.2 in |
| Tightening torque | Cable Lug 50 … 75 N·m |
| Tightening torque | Cable Lug 443 … 664 lbf·in |
| Utilization | Energy Storage System (ESS) |
| Utilization category | Switching of resistive loads, including moderate overloads - occasional actuation (DC-21B) |
| Utilization category | Switching of mixed resistive and inductive loads, including moderate overloads (i.e. shunt motors) - occasional actuation (DC-22B) |
| Utilization category | Switching of single PV string(s) without reverse and overcurrents (DC-PV1) |
| Utilization category | Switching of several PV string(s) with reverse and overcurrents (DC-PV2) |
Technical UL/CSA
| Maximum Operating Voltage | 1500Vdc, UL 98B |
| Ampere Rating | 400A,1500Vdc,UL98B |
| Short-circuit current rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers 10 kA |
| Short-circuit current rating (SCCR) | Fuse, see Catalog 50 kA |
| Tightening torque | Cable Lug 50 … 75 N·m |
| Tightening torque | Cable Lug 443 … 664 lbf·in |
Why Proax for ABB OTDC400UFV11-ESS?
Proax is an authorized distributor of ABB OTDC400UFV11-ESS and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Alternate Names | OTDC400UFV11ESS |
| Pack Size | 1 |
Recommended