A fully optimized four-pole DC switch-disconnector for 1000V utility-scale photovoltaic power plants covering 315-630A current range. The new design offers both a size reduction and an increase in efficiency and performance.
The four-pole 1000V DC Switch helps manufacturers improve system efficiency. The compact size of the new OTDC range makes it possible for manufacturers to reduce the size of combiner boxes and inverters.
Main characteristics for this switch:
Disconnect double PV circuit, Approved according to UL98B and IEC 60947-1,-3
Technical Specifications
Dimensions
Product Frame Size | M |
Product Net Width | 255.5 mm |
Product Net Width | 10.1 in |
Product Net Height | 211 mm |
Product Net Height | 8.3 in |
Product Net Depth / Length | 135 mm |
Product Net Depth / Length | 5.3 in |
Product Net Weight | 7.5 kg |
Product Net Weight | 16.5 lb |
Technical
Connection configuration | Double circuit 4a, 4c |
Rated Operational Current DC-21B (Ie) | (1000 V) 400 A |
Rated Operational Current DC-22B | (1000 V) 400 A |
Rated Operational Current DC-PV1 | (1000 V) 400 A |
Rated Operational Current DC-PV2 | (1000 V) 400 A |
Conventional Free-air Thermal Current (Ith) | Θ = 40 °C 400 A |
Conventional Thermal Current (Ithe) | Fully Enclosed 400 A |
Rated Impulse Withstand Voltage (Uimp) | 12 kV |
Rated Insulation Voltage (Ui) | 1500 V |
Rated Operational Voltage | 1000 V |
Rated Short-Circuit Making Capacity (Icm) | (1000 V DC) 10 kA |
Rated Short-time Withstand Current Low Voltage (Icw) | (1500 V DC) 10 kA |
Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 10 kA |
Protection Type | Circuit breaker |
Power Loss | at Rated Operating Conditions per Pole 12...13 W |
Pollution degree | 3 |
Handle Type | Handle and shaft not included |
Positive Opening Operation Torque (Direct Opening Action) | 18 … 30 N·m |
Shaft Diameter | 12 mm |
Shaft Diameter | 0.47 in |
Switches Operating Mechanism | Mechanism Between the Poles |
Switches Operating Mechanism | 22 (Between the Poles) |
Position of Line Terminals | Top In - Bottom Out |
Position of Line Terminals | Bottom In - Top Out |
Operating mode | Front Operated |
Standards | UL98B and IEC 60947-1, -3 |
Special Functions | No |
Mounting Type | Base mounting |
Number of Circuits | 2 |
Number of Poles | 4 |
Degree of Protection | Front IP20 |
Terminal Type | Lug terminals |
Terminal Width | 30 mm |
Terminal Width | 1.2 in |
Tightening torque | Cable Lug 30 … 44 N·m |
Tightening torque | Cable Lug 266 … 390 lbf·in |
Mechanical Durability | 10000 cycle |
Utilization | Photovoltaic |
Utilization category | Switching of resistive loads, including moderate overloads - occasional actuation (DC-21B) |
Utilization category | Switching of mixed resistive and inductive loads, including moderate overloads (i.e. shunt motors) - occasional actuation (DC-22B) |
Utilization category | Switching of single PV string(s) without reverse and overcurrents (DC-PV1) |
Utilization category | Switching of several PV string(s) with reverse and overcurrents (DC-PV2) |
Technical UL/CSA
Maximum Operating Voltage | 1000Vdc, UL 98B |
Ampere Rating | 320A,1000Vdc,UL98B |
Short-circuit current rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers 10 kA |
Tightening torque | Cable Lug 30 … 44 N·m |
Tightening torque | Cable Lug 266 … 390 lbf·in |
Why Proax for ABB OTDC320UF22?
Proax is an authorized distributor of ABB OTDC320UF22 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended